COMPREHENSIVE STUDY GUIDE 2026 FULL
QUESTIONS AND SOLUTIONS GRADED A+
• Passport Tag.
Answer: What are the two types of personnel accountability systems used?
• Rung raise Beam raise.
Answer: When raising a ladder, two methods may be used the __?__ raise or
the __?__ raise
• Class C.
Answer: What class fires involve energized electrical equipment things that
are charged?
• Friction loss.
Answer: The part of pressure that is used to overcome friction in the hose is?
• Foam itself.
Answer: Has the foam been stored outside in the elements, has the foam
expired, has the stored foam been tested by the department or laboratory?
These are all questions to ask for determining if the poor foam production is
due to the __?__
• Static pressure.
Answer: What is pressure in a system without water flowing?
• NIMS " National incident management system".
Answer: Resource management, command and coordination, and
communications and information management are the three components that
work together to form a building block approach to __?__
• Rapid fire Development.
Answer: __?__ refers to the rapid transition from the growth stage or early
decay stage to a ventilation Dash limited, fully developed stage.
,• Capture and control.
Answer: What protects the team by moving heat and flames away from team
members, giving them the ability to isolate the fuel source ?This is the most
effective method of attacking facility fires.
• Overhaul.
Answer: What is defined as searching for and putting out any fire that is still
burning after the main fire has been put out?
• LUNAR LIPS.
Answer: Firefighters should follow local protocols when communicating the
distress signal; however, two commonly used acronyms are used to help
remember the information that needs to be transmitted if it made a is called.
What other two acronyms?
• Site safety survey.
Answer: Exits, fire protection equipment, storage of hazardous materials,
and electrical hazards are the section areas to include in a__?__
• 3:1 and 5:1.
Answer: Fog nozzles are an example of non-air aspirating nozzles. Non-air
aspirating nozzles produce an expansion ratio between __?__ and __?__
• In- line eductors.
Answer: __?__ are some of the least expensive and simplest pieces of
proportion equipment available. For this reason, they are perhaps the most
common type of foam proportion are used in the fire service.
• 17%.
Answer: At what percent oxygen concentration does impairment occur?
• 14x18.
Answer: Salvage cover comes in what size?
• 1851.
Answer: NFPA __?__ is the Standard on the Selection, Care, and
maintenance of PPE
,• Structural hazards.
Answer: Trust construction, void spaces, and synthetic materials or several
specific types of __?__ which should be considered.
• 75 degrees.
Answer: The optimal angle of inclination is approximately __?__ degrees.
When the angles deviate from __?__ degrees, the ladder stability decreases
• Friction loss.
Answer: The part of pressure that is used to overcome friction in the hose is?
(5-18)
• Rung raise Beam raise.
Answer: When raising a ladder, to message may be used the __?__ raise or
the __?__ raise
• Flammable liquid or gas fire.
Answer: Identify the material involved , use assistance of the emergency
response guidebook, evaluate the threats to nearby materials, determine an
appropriate extinguishment agent, locate the shut off valve to shut down the
flow of material. These are several general steps used to control a __?__ or
__?__
• Two way radios.
Answer: IC traffic, priority traffic, and emergency traffic are the three types
of communication used on __?__
• Class C.
Answer: What class fires involve energized electrical equipment? (2-4)
• 1.) cooling 2.) containing the fire 3.) Controlling a certain aspect of the
situation.
Answer: Master streams are usually used to achieve one of what three
things? (5-21)
• Backdraft.
Answer: __?__ is when the fire is returned to fully involved state rapidly
, (often explosively) with the introduction of a new source of oxygen
• Extinguishment's.
Answer: Fires are classified for __?__ on the basis of what is burning.
• Daily, weekly, or when fire fighter reports for duty..
Answer: SCBA requires continual inspection and maintenance. Typically,
when are inspections performed?
• Pressure transfer extinguisher.
Answer: A unit with separate agent and expellant cylinders; pressure is
transferred to expel the agent when activated. (4-13)
• His/Her PPE should be quickly inspected by the incident safety officer or
other firefighters to ensure that all required PPE is donned, is being worn
correctly, and all closures are fastened..
Answer: What is require prior to a firefighter entering the incident? (3-3)
• Fire ground size up.
Answer: In order to determine what equipment needed, personnel must
complete a good __?__
• 19.5 % or below.
Answer: At what percent oxygen concentration does the occupational safety
and health administration require that supplied air be worn? (3-8)
• 1.5.
Answer: "If you don't know, don't go" for safety reasons, Responders should
maintain a distance of __?__ times the height of the area around the affected
area (1-7)
• 1.) Fire -retardant / first layer 2.) moisture barrier / second layer 3.) thermal
barrier / third layer.
Answer: The coat and pants are typically referred to as turn outs or bunker
gear. These items are required to meet NFPA 1971 and must be designed as
a three-layer system. What are the Three layers?
• Adapters.