HOT WORK AUTHORIZATIONS ARE TO BE ISSUED ____________. ✔Correct Answer-DAILY
HOT WORK PERMITS ARE ISSUED BY THE __________, THEY ARE DIFFERENT FROM HOT WORK
AUTHORIZATIONS. ✔Correct Answer-FDNY
A ____________ SHALL BE CONDUCTED BY THE RESPONSIBLE PERSON PRIOR TO WORK TO
ENSURE THAT ALL EQUIPMENT IS SAFE. ✔Correct Answer-PRE-HOT WORK CHECK
TRANSFERRING TANK TO LOADING RACK REQUIRES ________ COF HOLDER. ✔Correct
Answer-ONE
WHEN A FIRE PROTECTION SYS. IS OUT OF SERVICE, THE COF HOLDER MUST NOTIFY
____________. ✔Correct Answer-MANAGEMENT
THE P-13 COF HOLDER MUST ENSURE THAT TRUCKS ENTERING HAVE A VALID _____________.
✔Correct Answer-FDNY PERMIT
THE ____________ IS RESPONSIBLE FOR MAKING SURE THAT ALL FIRE SAFETY REGULATIONS
AND PROCEDURES ARE OBEYED ON THE PREMISES. ✔Correct Answer-COF HOLDER
ALL RECORDS SHOULD BE KEPT FOR AT LEAST ___________ YEARS. ✔Correct Answer-5
DEPENDING ON THE PRODUCT SERVICE, INTERIOR OF TANKS SHALL BE INSPECTED EVERY
____________ YEARS. ✔Correct Answer-10
___________ TANKS MAY BE USED TO STORE PRODUCTS WITH HIGH FLASH POINTS.
✔Correct Answer-CONE ROOF
A __________ SYSTEM MAY BE INSTALLED WHEN A CONE ROOF IS USED TO STORE PRODUCTS
WITH A LOW FLASH POINT. ✔Correct Answer-VAPOR RECOVERY SYSTEM
THE VAPOR RECOVERY UNITS MUST BE INSPECTED AT LEAST ONCE EVERY ___________
MONTHS. ✔Correct Answer-6
THERE ARE TWO TYPES OF FLOATING ROOF TANKS: __________ AND ___________. ✔Correct
Answer-OPEN-TOP AND COVERED TOP
, VENTS FOR FLOATING ROOF TANKS ARE LOCATED BETWEEN THE ________________.
✔Correct Answer-FLOATING ROOF AND ACTUAL ROOF
MAX HEIGHT OF AN ABOVEGROUND FLAMMABLE AND COMBUSTIBLE TANK SHALL NOT EXCEED
____________ FEET. ✔Correct Answer-40
ABOVEGROUND VERTICAL CYLINDRICAL TANKS STORING COMBUSTIBLE LIQUIDS SHALL NOT
EXCEED ______________ FEET. ✔Correct Answer-48
ANYTIME A TANK IS ALTERED OR REPAIRED, IT IS SUBJECT TO A ____________ STANDING
WATER TEST. ✔Correct Answer-24 HOUR
VARECS SHALL BE TESTED ________ FOR ACCURACY AND FREEDOM OF MOVEMENT.
✔Correct Answer-EVERY YEAR
TANK FIELDS MUST BE INSPECTED DAILY FOR COMBUSTIBLE TRASH, ACCUMULATION OF
CORROSION, AND ___________ BUILDUP. ✔Correct Answer-ICE
THE HIGH ALARMS SHALL BE CONNECTED TO THE _____________ OFFICE. ✔Correct Answer-
DISPATCHER'S
TANKS FILLED BY ANY PIPELINE SHALL BE PROVIDED WITH A __________ VALVE. ✔Correct
Answer-BRODIE
THE "HI" ALARM SHOULD BE CALIBRATED TO A FILL LEVEL OF ___________ PERCENT.
✔Correct Answer-95
THE "HI-HI" ALARM SHOULD BE CALIBRATED TO A FILL LEVEL OF __________ PERCENT.
✔Correct Answer-98
EACH SINGLE DIKE WALL ENCLOSURE SHALL HAVE A CAPACITY EQUAL TO _________ PERCENT
OF THE TANK'S CAPACITY. ✔Correct Answer-110
TANKS ARRANGED IN GROUPS WITH A TOTAL CAPACITY NOT EXCEEDING ___________ GALLONS
MAY BE ENCLOSED IN A SINGLE DIKE ENCLOSURE. ✔Correct Answer-500,000
INTERMEDIATE DIKES SHALL NOT BE LESS THAN _________ INCHES IN HEIGHT. ✔Correct
Answer-18
WHEN TWO OR MORE TANKS ARE LOCATED IN A COMMON DIKED AREA, INTERMEDIATE DIKES
SHALL BE PROVIDED TO HOLD AT LEAST __________ PERCENT. ✔Correct Answer-10
________ SHALL NOT PASS THROUGH ADJACENT DIKED AREAS OR IMPOUNDING BASINS.
✔Correct Answer-PIPING