exam with answers |\ |\
The ______asummes the entire responsibility under the contract -
|\ |\ |\ |\ |\ |\ |\ |\ |\
CORRECT ANSWERS ✔✔Prime Contractor |\ |\ |\
The ______ asummes responsibility with respect to his portion of
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
the work - CORRECT ANSWERS ✔✔Sub Contractor
|\ |\ |\ |\ |\ |\
Safety Belts shall be a min of 1/2 inch nylon and not allow a fall
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
greater than ____ - CORRECT ANSWERS ✔✔6ft
|\ |\ |\ |\ |\ |\
Safety Nets must extend _____ beyond the end of work surface -
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
CORRECT ANSWERS ✔✔8ft |\ |\
Safety Nets must be positioned no more than _____ below work
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
surface - CORRECT ANSWERS ✔✔25ft
|\ |\ |\ |\
Heaters must not be located within ______ft of tarps, canvas or
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
similar coverings - CORRECT ANSWERS ✔✔10ft
|\ |\ |\ |\ |\
,Material Storage : Materials shall not be stored within ____ ft of an
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
exterior wall - CORRECT ANSWERS ✔✔10ft
|\ |\ |\ |\ |\
Materaial Storage : Brick stacks shall not be more than _____ft in
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
height - CORRECT ANSWERS ✔✔7ft
|\ |\ |\ |\
Material Storage : When masonry blocks are stacked higher than
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
_____ ft the stack shall be tapered back 1 half block per tier above
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
the ____ft line - CORRECT ANSWERS ✔✔6ft
|\ |\ |\ |\ |\ |\
Material Storage : Lumber Piles shall not exceed ______ft in height
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
(mechanically) - CORRECT ANSWERS ✔✔20ft |\ |\ |\ |\
Material Storage - Lumber piles shall not exceed _____ in height
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
(manually) - CORRECT ANSWERS ✔✔16ft |\ |\ |\ |\
A chute is required if waste material is dropped more than _____ft
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
outside exterior walls of building - CORRECT ANSWERS ✔✔20ft
|\ |\ |\ |\ |\ |\ |\ |\
How far do you Lap Durawire - CORRECT ANSWERS ✔✔8 Inches
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
workers in _____ spaces must be provided a lifeline/safety belt -
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
CORRECT ANSWERS ✔✔Confined |\ |\
,means a suspension scaffold consisting of a platform supported by
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
two essentially horiztonal & parallel ropes attached to structural
|\ |\ |\ |\ |\ |\ |\ |\ |\
members of a building or other structure - CORRECT ANSWERS
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
✔✔Catenary Scaffold |\
employer ensures that employees who wear presc lenses while
|\ |\ |\ |\ |\ |\ |\ |\ |\
engaged in operations needing eye protection - CORRECT
|\ |\ |\ |\ |\ |\ |\ |\
ANSWERS ✔✔Prescription Lenses |\ |\
Maximum height of a masonry pier used in a seismic zone is _____
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
- CORRECT ANSWERS ✔✔12ft
|\ |\ |\ |\
means a suspension scaffold consisting of a braced platform resin on
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
two parallel bearers & hung from overhead supports by ropes of
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
fixed length - CORRECT ANSWERS ✔✔Float (Ship) Scaffold
|\ |\ |\ |\ |\ |\ |\
The leading reason for erosion and sediment conrol plan failure is
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
_____ - CORRECT ANSWERS ✔✔Lack Of Maintenance
|\ |\ |\ |\ |\ |\
To clean masory use _______ - CORRECT ANSWERS ✔✔Potable
|\ |\ |\ |\ |\ |\ |\ |\ |\
Water & Detergents |\ |\
, No Masonry shall be supported on ______ or other forms of _____
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
construction - CORRECT ANSWERS ✔✔Wood Girders : Wood |\ |\ |\ |\ |\ |\ |\
_______ Shall be anchored to masonry walls with 1/2" diameter
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
bolts 6ft on center or equivalent. Bolt shall extend & be embedded
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
at least _____ in the masonry - CORRECT ANSWERS ✔✔Roof
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
Diaphragms : 15 Inches |\ |\ |\
Minimum thickness of a parapet wall - CORRECT ANSWERS ✔✔8
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\
Inches
Maximum spacing of light gauge studs - CORRECT ANSWERS
|\ |\ |\ |\ |\ |\ |\ |\ |\
✔✔24 Inches |\
Mechanicla connections shall have the bars connection to develop
|\ |\ |\ |\ |\ |\ |\ |\ |\
in tension or compression as least 125% of the yield strength of the
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
bar - CORRECT ANSWERS ✔✔TRUE
|\ |\ |\ |\
Is a hardhat required with a jack hammer? - CORRECT ANSWERS
|\ |\ |\ |\ |\ |\ |\ |\ |\ |\ |\
✔✔No
What is preferred safety traffic marker? - CORRECT ANSWERS
|\ |\ |\ |\ |\ |\ |\ |\ |\
✔✔42" Reflectorized Barrell or Drum
|\ |\ |\ |\