According to the IFC Chapter 3 power point presentation , hot ashes and
combustible ignition sources are not supposed to be placed within ___ft of
combustibles (including walls), or within ____ft of building openings.
A) 10, 2
B) 100, 20
C) 1000, 200
D) 1, 2000 -ANSWERS-10, 2
__________ feet is the minimum unobstructed height above fire lanes or fire
apparatus access roads.
A. 12
B. 13
C. 13.5
D. 20 -ANSWERS-13.5
The cause of most failures in Industrial furnaces and ovens can be traced to:
A) Inadequate training of operators
B) Lack of proper maintenance
C) Improper application of equipment
,D) all the the above -ANSWERS-all the the above
Fire-extinguishing agents used in fixed dry-chemical systems are generally the
same types that are used in portable fire extinguishers.
a. True
b. False -ANSWERS-True
Wet chemical fire-extinguishing agents are typically composed of water and
either one of three agents. Which of the following is not one of the three listed in
the book?
A Potassium carbonate
B Potassium bicarbonate
C potassium acetate
D potassium ctrate -ANSWERS-Potassium bicarbonate
The proper mounting height of a multipurpose dry chemical fire extinguisher,
weighing less than 40 pounds, is between _______ inches and _______ inches.
A. 2 and 48
B. 4 and 44
C. 2 and 60
D. 4 and 60 -ANSWERS-4 and 60
There are 5 kinds of special-agent fire-extinguishing systems. Which one listed
below is INCORRECT.
A. Dry Chemical
,B. Wet Chemical
C. Dirty Agent
D. Carbon Dioxide -ANSWERS-Dirty Agent
When conducting an acceptance test for a paint booth the first nozzle in the
exhaust duct must be located just inside the duct entrance. The remaining nozzles
must be spaced how far apart?
A. Within 5 feet of each other
B. Within 10 feet of each other
C. Within 12 feet of each other
D. Within 15 feet of each other -ANSWERS-Within 12 feet of each other
Regarding fire extinguisher ratings, extinguishers undergo 3 tests to determine
their Class A rating. Which of the following tests DOES NOT occur?
1. Wood Panel
2. Wood Trim
3. Wood Crib
4. Excelsior -ANSWERS-Wood Trim
NFPA 72 also requires that pull stations be placed within __________ of every exit
so that facility occupants can activate an alarm while they are exiting the facility.
a. At the door
b. 5 feet
c. 10 feet
d. 15 feet -ANSWERS-5
, The secondary power supply must be able to make the fire detector and alarm
system fully operational within _____ seconds of main power supply failure.
A. 10 sec
B. 20 sec
C. 30 sec
D. 60 sec -ANSWERS-30 sec
A secondary power supply must be provided for a fire detection and alarm
system, so that the system will be operational even if the main power supply fails.
The secondary system must be able to make the fire detection and alarm system
fully operational within ____ seconds of the main power supply's failure.
A. 10
B. 20
C. 30
D. 45 -ANSWERS-30
Manual pull stations can be single-action or ______ -action?
A. married
B. double
C. multiple
D. single -ANSWERS-double
A secondary power supply must be provided for a fire detection and alarm
system. The secondary system must be able to make the fire detection & alarm
system fully operational within __ seconds of the main power supply's failure.