STCW_Test_-Answers_Report_Management Questions and answers.
STCW Test - Answers Report
(Management)
Questions Asked: What rules and regulations are regulating the watch keeping routines in the engine room?
76
Should Answer: Both STCW and Class rules
Questions Asked: Watch keeping engineers shall have a minimum of knowledge of the vessel's engine room and
77 operation of its functions prior to being accepted as Engineer on Duty, and shall acknowledge his
Should Answer: He shall have all the knowledge as listed in the other alternatives
Questions Asked: The duty engineer of a UMS ship is approached by a member of the ship's staff, seeking permission to
113 hang wet working clothes in the engine room to dry. Should he:
Should Answer: Not allow the clothes to be hung anywhere in the unmanned machinery spaces.
Questions Asked: What is a fire wire?
117
Should Answer: Wire for pulling burning ships off the pier
Questions Asked: How often shall crew members participate in fire drills?
118
Should Answer: Once every month
Questions Asked: Which of the following items shall be included in each fire drill?
119
Should Answer: Checking the operation of watertight doors, fire doors, fire dampers and relevant communication
Questions Asked: You are on night time duty as navigating officer on a ship under way, when a fire in the crew's
120 accommodation is reported. What is the first action you would take?
Should Answer: Sound the fire alarm signal
Questions Asked: The smoke detector (fire indicator) indicates fire in a cargo hold loaded by general cargo. What first
121 action should be taken?
Should Answer: Close the ventilation system and other openings to the hold in order to choke the fire
Questions Asked: When a fire breaks out in the accommodation, cargo holds or on deck, who is in charge of the fire
124 fighting operations?
Should Answer: The Chief Officer
Questions Asked: When a fire breaks out in the engine room, who is in charge of the fire fighting
operations? 125
Should Answer: The Chief Engineer
Questions Asked: What manoeuvre should be carried out in case of a fire onboard a ship?
126
Should Answer: Reduce speed and, if possible, keep the fire zone to the leeward of the ship
Questions Asked: What has to be done before the central gas extinguishing system is used on a fire in engine
,STCW_Test_-Answers_Report_Management Questions and answers.
129 rooms, cargo holds or other confined spaces?
Should Answer: Make sure that the compartment has been evacuated
,STCW_Test_-Answers_Report_Management Questions and answers.
Questions Asked: In case a fire alarm is sounded from the bridge, what action would you take as Engineer on
Duty? 130
Should Answer: Start the fire pump
Questions Asked: What alarm signal is to be sounded by the alarm bells in case of fire onboard ships?
131
Should Answer: Series of short blasts
Questions Asked: According to basic principles regarding fire protection the ship is to be divided in zones by
132 structural and thermal boundaries. Which? (SOLAS II-2/2.2.1)
Should Answer: In main vertical zones
Questions Asked: Which spaces, in regard to fire protection, shall be separated from the rest of the ship by thermal and
133 structural boundaries? (SOLAS II-2/2.2.2)
Should Answer: Accommodation
Questions Asked: What type of construction material should be avoided regarding fire protection purposes?
134 (SOLAS II-2/2.2.3)
Should Answer: All combustible materials
Questions Asked: In case of diesel driven fire pumps, for how long period shall the fuel tank capacity allow the pump
136 to be run at full capacity? (SOLAS II-2/4.3.3.2.3)
Should Answer: Three hours
Questions Asked: What is the maximum allowed suction head for fire pumps? (SOLAS II-2/4.3.3.2.5)
138
Should Answer: 4.5 meters
Questions Asked: In case each hydrant is not fitted with hose and nozzles, what is the requirement? (SOLAS II-2/4.6.1)
141
Should Answer: Complete interchangeability of hose couplings and nozzles
Questions Asked: What number of fire hoses is required for cargo ships of 1000 tons gross and
upwards? 144 (SOLAS II-2/4.7.4.1)
Should Answer: One hose for each 30 meter length of ship plus one spare. Hoses for engine and boiler room in addition
Questions Asked: What type of nozzles for fire hoses shall be used aboard ships? (SOLAS II-
2/4.8.4) 145
Should Answer: Dual purpose (jet/spray) type incorporating shutoff
Questions Asked: What types of gases are not allowed as fire-extinguishing medium for fixed gas
146 fire-extinguishing system aboard ships? (SOLAS II-2/5.1.1)
Should Answer: Toxic gases
Questions Asked: What type of fire-extinguishing medium release is allowed for fixed gas fire-extinguishing
147 installations? (SOLAS II-2/5.1.8)
Should Answer: Manual operated release system only
Questions Asked: In which compartments are halogenated hydrocarbons not allowed as fire-extinguishing
149 media? (SOLAS II-2/5.3.1)
Should Answer: General cargo holds
Questions Asked: For carbon dioxide fire-fighting systems for machinery spaces the fixed piping system shall be
150 such that: (SOLAS II-2/5.2.4)
Should Answer: 85% of the gas can be discharged into the space within two minutes
, STCW_Test_-Answers_Report_Management Questions and answers.
Questions Asked: The discharge arrangements for halogenated hydrocarbon total flooding systems shall be so
151 designed that the minimum quantity of medium can be discharged in (based on the discharge of the
STCW Test - Answers Report
(Management)
Questions Asked: What rules and regulations are regulating the watch keeping routines in the engine room?
76
Should Answer: Both STCW and Class rules
Questions Asked: Watch keeping engineers shall have a minimum of knowledge of the vessel's engine room and
77 operation of its functions prior to being accepted as Engineer on Duty, and shall acknowledge his
Should Answer: He shall have all the knowledge as listed in the other alternatives
Questions Asked: The duty engineer of a UMS ship is approached by a member of the ship's staff, seeking permission to
113 hang wet working clothes in the engine room to dry. Should he:
Should Answer: Not allow the clothes to be hung anywhere in the unmanned machinery spaces.
Questions Asked: What is a fire wire?
117
Should Answer: Wire for pulling burning ships off the pier
Questions Asked: How often shall crew members participate in fire drills?
118
Should Answer: Once every month
Questions Asked: Which of the following items shall be included in each fire drill?
119
Should Answer: Checking the operation of watertight doors, fire doors, fire dampers and relevant communication
Questions Asked: You are on night time duty as navigating officer on a ship under way, when a fire in the crew's
120 accommodation is reported. What is the first action you would take?
Should Answer: Sound the fire alarm signal
Questions Asked: The smoke detector (fire indicator) indicates fire in a cargo hold loaded by general cargo. What first
121 action should be taken?
Should Answer: Close the ventilation system and other openings to the hold in order to choke the fire
Questions Asked: When a fire breaks out in the accommodation, cargo holds or on deck, who is in charge of the fire
124 fighting operations?
Should Answer: The Chief Officer
Questions Asked: When a fire breaks out in the engine room, who is in charge of the fire fighting
operations? 125
Should Answer: The Chief Engineer
Questions Asked: What manoeuvre should be carried out in case of a fire onboard a ship?
126
Should Answer: Reduce speed and, if possible, keep the fire zone to the leeward of the ship
Questions Asked: What has to be done before the central gas extinguishing system is used on a fire in engine
,STCW_Test_-Answers_Report_Management Questions and answers.
129 rooms, cargo holds or other confined spaces?
Should Answer: Make sure that the compartment has been evacuated
,STCW_Test_-Answers_Report_Management Questions and answers.
Questions Asked: In case a fire alarm is sounded from the bridge, what action would you take as Engineer on
Duty? 130
Should Answer: Start the fire pump
Questions Asked: What alarm signal is to be sounded by the alarm bells in case of fire onboard ships?
131
Should Answer: Series of short blasts
Questions Asked: According to basic principles regarding fire protection the ship is to be divided in zones by
132 structural and thermal boundaries. Which? (SOLAS II-2/2.2.1)
Should Answer: In main vertical zones
Questions Asked: Which spaces, in regard to fire protection, shall be separated from the rest of the ship by thermal and
133 structural boundaries? (SOLAS II-2/2.2.2)
Should Answer: Accommodation
Questions Asked: What type of construction material should be avoided regarding fire protection purposes?
134 (SOLAS II-2/2.2.3)
Should Answer: All combustible materials
Questions Asked: In case of diesel driven fire pumps, for how long period shall the fuel tank capacity allow the pump
136 to be run at full capacity? (SOLAS II-2/4.3.3.2.3)
Should Answer: Three hours
Questions Asked: What is the maximum allowed suction head for fire pumps? (SOLAS II-2/4.3.3.2.5)
138
Should Answer: 4.5 meters
Questions Asked: In case each hydrant is not fitted with hose and nozzles, what is the requirement? (SOLAS II-2/4.6.1)
141
Should Answer: Complete interchangeability of hose couplings and nozzles
Questions Asked: What number of fire hoses is required for cargo ships of 1000 tons gross and
upwards? 144 (SOLAS II-2/4.7.4.1)
Should Answer: One hose for each 30 meter length of ship plus one spare. Hoses for engine and boiler room in addition
Questions Asked: What type of nozzles for fire hoses shall be used aboard ships? (SOLAS II-
2/4.8.4) 145
Should Answer: Dual purpose (jet/spray) type incorporating shutoff
Questions Asked: What types of gases are not allowed as fire-extinguishing medium for fixed gas
146 fire-extinguishing system aboard ships? (SOLAS II-2/5.1.1)
Should Answer: Toxic gases
Questions Asked: What type of fire-extinguishing medium release is allowed for fixed gas fire-extinguishing
147 installations? (SOLAS II-2/5.1.8)
Should Answer: Manual operated release system only
Questions Asked: In which compartments are halogenated hydrocarbons not allowed as fire-extinguishing
149 media? (SOLAS II-2/5.3.1)
Should Answer: General cargo holds
Questions Asked: For carbon dioxide fire-fighting systems for machinery spaces the fixed piping system shall be
150 such that: (SOLAS II-2/5.2.4)
Should Answer: 85% of the gas can be discharged into the space within two minutes
, STCW_Test_-Answers_Report_Management Questions and answers.
Questions Asked: The discharge arrangements for halogenated hydrocarbon total flooding systems shall be so
151 designed that the minimum quantity of medium can be discharged in (based on the discharge of the