NCC Electronic Fetal Monitoring Certification 2022 graded A new practice exam solution Which of the following factors can have a negative effect on uterine blood flow? a. Hypertension b. Epidural c. Hemorrhage d. Diabetes e. All of the above - CORRECT ANSWER e. All of the above How does the fetus compensate for decreased maternal circulating volume? a. Increases cardiac output by increasing stroke volume. b. Increases cardiac output by increasing it's heart rate. c. Increases cardiac output by increasing fetal movement. - CORRECT ANSWER b. Increases cardiac output by increasing it's heart rate. Stimulating the vagus nerve typically produces: a. A decrease in the heart rate b. An increase in the heart rate c. An increase in stroke volume d. No change - CORRECT ANSWER a. A decrease in the heart rate What initially causes a chemoreceptor response? a. Epidurals b. Supine maternal position c. Increased CO2 levels d. Decreased O2 levels e. A & C f. A & B g. C & D - CORRECT ANSWER g. C & D The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect to the FHR baseline? a. Increases baseline b. Decreases baseline - CORRECT ANSWER b. Decreases baseline T/F: Oxygen exchange in the placenta takes place in the intervillous space. - CORRECT ANSWER True T/F: The parasympathetic nervous system is a cardioaccelerator. - CORRECT ANSWER False T/F: Baroreceptors are stretch receptors which respond to increases or decreases in blood pressure. - CORRECT ANSWER True

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

NCC Electronic Fetal Monitoring Certification 2022 graded A
new practice exam solution

Which of the following factors can have a negative effect on uterine blood flow?
a. Hypertension
b. Epidural
c. Hemorrhage
d. Diabetes
e. All of the above - CORRECT ANSWER e. All of the above

How does the fetus compensate for decreased maternal circulating volume?
a. Increases cardiac output by increasing stroke volume.
b. Increases cardiac output by increasing it's heart rate.
c. Increases cardiac output by increasing fetal movement. - CORRECT ANSWER b.
Increases cardiac output by increasing it's heart rate.

Stimulating the vagus nerve typically produces:
a. A decrease in the heart rate
b. An increase in the heart rate
c. An increase in stroke volume
d. No change - CORRECT ANSWER a. A decrease in the heart rate

What initially causes a chemoreceptor response?
a. Epidurals
b. Supine maternal position
c. Increased CO2 levels
d. Decreased O2 levels
e. A & C
f. A & B
g. C & D - CORRECT ANSWER g. C & D

The vagus nerve begins maturation 26 to 28 weeks. Its dominance results in what effect
to the FHR baseline?
a. Increases baseline
b. Decreases baseline - CORRECT ANSWER b. Decreases baseline

T/F: Oxygen exchange in the placenta takes place in the intervillous space. -
CORRECT ANSWER True

T/F: The parasympathetic nervous system is a cardioaccelerator. - CORRECT
ANSWER False

T/F: Baroreceptors are stretch receptors which respond to increases or decreases in
blood pressure. - CORRECT ANSWER True

,T/F: There are two electronic fetal monitoring methods of obtaining the fetal heart rate:
the ultrasound transducer and the fetal spiral electrode. - CORRECT ANSWER True

T/F: Variability can be determined with the fetoscope. - CORRECT ANSWER False

T/F: Because the ultrasound transducer and toco transducer are sealed units, they can
be dipped in warm water to make cleaning easier. - CORRECT ANSWER False

T/F: The most common artifact with the ultrasound transducer system for fetal heart rate
is increased variability. - CORRECT ANSWER True

T/F: All fetal monitors contain a logic system designed to reject artifact. - CORRECT
ANSWER True

T/F: The monitor should always be tested before starting a tracing, either external or
internal mode and labeled a test. - CORRECT ANSWER True

T/F: The paper speed on the fetal monitor should always be set at 1cm/min. -
CORRECT ANSWER False

T/F: Both internal and external monitoring methods are equally accurate means of
obtaining the fetal heart rate and contraction patterns. - CORRECT ANSWER False

T/F: The external toco is usually placed over the uterine fundus to pick up contractions.
- CORRECT ANSWER True

T/F: The external toco gives measurable uterine pressure. - CORRECT ANSWER False

T/F: The fetal spiral electrode can be placed when vaginal bleeding of unknown origin is
present. - CORRECT ANSWER False

T/F: The ultrasound transducer is usually placed on the side of the uterus over the
baby's back, as the fetal heart is heard best there. - CORRECT ANSWER True

T/F: The spiral electrode is used to more accurately determine the frequency, duration,
and intensity of uterine contractions. - CORRECT ANSWER False

T/F: The heart rate from a well-applied fetal spiral electrode can only be fetal, not
maternal. - CORRECT ANSWER False

T/F: The intrauterine catheter is used to pick up the fetal heart rate. - CORRECT
ANSWER False

T/F: The internal spiral electrode may pick up the maternal heart rate if the baby has
died. - CORRECT ANSWER True

,T/F: Fetal arrhythmias can be seen on both internal and external monitor tracings. -
CORRECT ANSWER True

T/F: Variability and periodic changes can be detected with both internal and external
monitoring. - CORRECT ANSWER True

T/F: Variable decelerations are a result of cord compression. - CORRECT ANSWER
True

T/F: The presence of FHR accelerations in the intrapartum and antepartum periods is a
sign of adequate fetal oxygenation. - CORRECT ANSWER True

T/F: Variable decelerations are a vagal response. - CORRECT ANSWER True

T/F: Late decelerations have a gradual decrease in FHR (onset to nadir 30 seconds)
and are delayed in timing with the nadir of the deceleration occurring after the peak of
the contraction. - CORRECT ANSWER True

T/F: The fetal heart rate baseline can be determined during periods of marked
variability. - CORRECT ANSWER False

T/F: Anything that affects maternal blood flow (cardiac output) can affect the blood flow
through the placenta. - CORRECT ANSWER True

T/F: Variable decelerations are the most frequently seen fetal heart rate deceleration
pattern in labor. - CORRECT ANSWER True

T/F: Minimal variability is always an indicator of hypoxia and a Cesarean section is
indicated. - CORRECT ANSWER False

What is your first intervention in management of a patient experiencing variable
decelerations?
a. Immediate delivery
b. Change maternal position
c. No treatment indicated
d. Oxygen
e. Stop oxytocin infusion - CORRECT ANSWER b. Change maternal position

Etiology of a baseline FHR of 165bpm occurring for the last hour can be:
1. Maternal supine hypotension
2. Maternal fever
3. Maternal dehydration
4. Unknown
a. 1 and 2
b. 1, 2 and 3
c. 2, 3 and 4 - CORRECT ANSWER c. 2, 3 and 4

, What is the most probable cause of recurrent late decelerations?
a. Utero-placental insufficiency
b. Head compression
c. Cord compression
d. Maternal position change - CORRECT ANSWER a. Utero-placental insufficiency

The most prevalent risk factor associated with fetal death before the onset of labor is:
a. Low socioeconomic status
b. Fetal malpresentation
c. Uteroplacental insufficiency
d. Uterine anomalies - CORRECT ANSWER c. Uteroplacental insufficiency

Which of the following is NOT used for antepartum fetal surveillance?
a. Fetal movement counting
b. Antepartum fetal heart rate testing
c. Biophysical profile testing
d. Maternal HCG levels - CORRECT ANSWER d. Maternal HCG levels

Which of the following conditions is not an indication for antepartum fetal surveillance?
a. Gestational hypertension
b. Diabetes in pregnancy
c. Fetus in breech presentation
d. Decreased fetal movement - CORRECT ANSWER c. Fetus in breech presentation

Which of the following does not affect the degree of fetal activity?
a. Vibroacoustic stimulation
b. Smoking
c. Fetal position
d. Gestational age - CORRECT ANSWER a. Vibroacoustic stimulation

To be considered reactive, a nonstress test must have:
a. 4 fetal heart rate accelerations in a 20 minute window
b. 2 fetal heart rate accelerations in a 10 minute window
c. 4 fetal heart rate accelerations in a 40 minute window
d. 2 fetal heart rate accelerations in a 20 minute window - CORRECT ANSWER d. 2
fetal heart rate accelerations in a 20 minute window

If a nonstress test is nonreactive after 40 minutes, the next step should be:
a. Have the client go home and do fetal movement counts
b. Do a biophysical profile or contraction stress test
c. Repeat the nonstress test within a week
d. Admit the client for delivery - CORRECT ANSWER b. Do a biophysical profile or
contraction stress test

All of the following are components of a biophysical profile except:

Geschreven voor

Vak

Documentinformatie

Geüpload op
13 juli 2022
Aantal pagina's
59
Geschreven in
2021/2022
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$16.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
smartzone Liberty University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
3367
Lid sinds
6 jaar
Aantal volgers
2296
Documenten
14608
Laatst verkocht
2 dagen geleden
AMAIZING EDUCATION WORLD

GET ALL KIND OF EXAMS ON THIS PAGE ,COMPLETE TEST BANKS,SUMMARIES,STUDY GUIDES,PROJECT PAPERS,ASSIGNMENTS,CASE STUDIES, YOU CAN ALSO COMMUNICATE WITH THE SELLER FOR ANY PRE-ORDER,ORDER AND ETC.

3.6

610 beoordelingen

5
271
4
96
3
106
2
32
1
105

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen