The purpose of this code is to establish ___________ requirements to safeguard the public
safety, health and general welfare. Correct Answer: "Minimum"
2015 IRC Section R101.3 Intent
Where, in any specific case, different sections of this code specify different materials, methods
of construction or other requirements, the most __________ shall govern. Correct Answer:
"Restrictive"
2015 IRC Section R102.1 General
Where a referenced code or standard includes subject matter that is within the scope of the IRC,
the provisions of the ___________ shall take precendence. Correct Answer: "IRC"
2015 IRC Section R102.4.2 Provisions in referenced codes and standards
An alternative material or method shall be approved where the proposed design is ____________
and complies with the _________ of the code. Correct Answer: "Satisfactory" / "Intent"
2015 IRC Section R104.11 Alternative materials, design and methods of construction and
equipment.
Compliance with the specific ____________-based provisions of the International Codes in lieu
of specific requirements of the IRC shall be permitted as an alternative. Correct Answer:
"Performance"
2015 IRC Section R104.11 Alternative materials, design and methods of construction and
equipment.
A permit is not required for one-story detached accessory structures provided that the floor area
does not exceed ___ sq ft. Correct Answer: "200"
2015 IRC Section R105.2 Work exempt from permit, Building:Exception 1.
Fences that are ___ feet or less in height do not require permits. Correct Answer: "7"
2015 IRC Section R105.2 Work exempt from permit, Building: Exception 2.
A permit is not required for the replacement of branch circuit over current devices (breakers) of
the required capacity in the same location (within a panel). Correct Answer: "True"
2015 IRC Section R105.2 Work exempt from permit, Electrical: Exception 3.
Unattached decks not exceeding _____ sq ft in area, that are not more than ____ inches above
grade do not require a permit. Correct Answer: "200" / "30" provided the decks do not serve the
exit door required by Section R311.4.
2015 IRC Section R105.2 Work exempt from permit, Building: Exception 10.
Where equipment replacements and repairs must be performed in an emergency situation, the
permit application shall be submitted within the ________ _________ business day. Correct
Answer: "Next working" ...to the building official.
2015 IRC Section R105.2.1 Emergency repairs.
, An application for a permit for any proposed work shall be deemed to have been abandoned
_____ days after the filing date. Correct Answer: "180"; also applies to extensions.
2015 IRC Section R105.3.2 Time limitation of application.
Before issuing a permit, the building official is __________ to examine or cause to be examined
buildings, structures and sites for which an application has been filed. Correct Answer:
"Authorized"
2015 IRC Section R105.9 Preliminary inspection.
When the building official issues a permit, the construction documents shall be provided in
writing or by a stamp which states _______ ________ ________ ________. Correct Answer:
"REVIEWED FOR CODE COMPLIANCE"
2015 IRC Section R106.3.1 Approval of construction documents.
Final inspection shall be made after the permitted work is ___________ and prior to
___________. Correct Answer: "Complete" / "occupancy"
2015 IRC Section R109.1.6 Final Inspection
If located in a flood hazard area, the documentation of elevations required in a Section R322.1.10
shall be submitted to the building official prior to the _________ inspection. Correct Answer:
"Final"
2015 IRC Section R109.1.6.1 Elevation documentation.
Signifies access that requires the removal of an access panel or similar removable obstruction.
Correct Answer: "Accessible"; Readily Accessible signifies access without the necessity for
removing a panel or similar obstruction.
2015 IRC Section R202 Definitions.
A finished or unfinished area, not considered a story, where the occupiable space is enclosed by
the roof assembly above and the floor-ceiling assembly below is a ____________. Correct
Answer: "Habitable attic" Other conditions relating to occupiable floor area must also be met.
2015 IRC Section R202 Definitions.
A wall supporting any vertical load in addition to its own weight is a ________-________ wall.
Correct Answer: "Load-bearing"
2015 IRC Section R202 Definitions (Definition of WALLS, Load-Bearing Wall).
Hot Water is water at a temperature greater than or equal to _____ F. Correct Answer: "110"
2015 IRC Section R202 Definitions (Definition of HOT WATER).
What is the minimum uniformly distributed live load for habitable attics and attics served with
fixed stairs? Correct Answer: "30 pounds per square foot" Review of tables will be useful as
knowledge of many tables is necessary for the exam.
2015 IRC Table R301.5 Minimum Uniformly Distributed Live Loads.