Conductors in NM cable assemblies shall be rated at ___°C. - 90°C Watch out here, it also reads the 90°C rating shall be permitted to be used for ampacity correction and adjustment purposes provided that the final corrected or adjusted ampacity does not exceed that for a 60°C rated conductor. E3705.4.4 Conductors of type NM cable. Insulated conductors and cables exposed to direct rays of sun shall be listed and labeled ____ _____. - Sunlight resistant E3802.3.3 Locations exposed to direct sunlight. Where raceways are installed in wet locations above grade, the interior of such raceways shall be considered to be a ____ location. - Wet Insulated conductors and cables installed in raceways in wet locations above grade shall be listed for use in wet locations.

Show more Read less
Institution
Course

Content preview

IRC Electrical Test with COMPLETE SOLUTION
Conductors in NM cable assemblies shall be rated at ___°C. Correct Answer: 90°C

Watch out here, it also reads the 90°C rating shall be permitted to be used for ampacity
correction and adjustment purposes provided that the final corrected or adjusted ampacity does
not exceed that for a 60°C rated conductor.

E3705.4.4 Conductors of type NM cable.

Insulated conductors and cables exposed to direct rays of sun shall be listed and labeled ____
_____. Correct Answer: Sunlight resistant

E3802.3.3 Locations exposed to direct sunlight.

Where raceways are installed in wet locations above grade, the interior of such raceways shall be
considered to be a ____ location. Correct Answer: Wet

Insulated conductors and cables installed in raceways in wet locations above grade shall be listed
for use in wet locations.

E3802.7 Raceways in wet locations above grade.

Underground service laterals that are not encased in concrete and that are buried 18 inches or
more below grade shall have their location identified by a ___ ____. Correct Answer: Warning
ribbon

That is placed in the trench at least 12 inches above the underground installation.

E3803.2 Warning ribbon.

Receptacles shall be installed so that no point along the floor in any wall space is more than ____
feet, measured horizontally, from an outlet in that space. Correct Answer: 6 ft.

The 6/12 rule. 6' from any door opening and ever 12' after that measured along the wall.

E3901.2.1 Spacing.

Kitchen counter top receptacles shall be installed so that no point along the wall line is more than
____ inches from a receptacle. Correct Answer: 24 in.

The 2/4 rule. 2 feet from any opening and every 4 feet after that.

E3901.4.1 Wall counter space.

, At least one receptacle outlet in bathrooms is required to be within ____ inches of each lavatory
basin. Correct Answer: 36 in.

E3901.6 Bathroom.

There shall be a wall switch at each floor to control stairway lighting where the stairway has
____ or more risers. Correct Answer: 6

E3903.3 Additional locations.

Nonmetallic boxes shall be used only with cable wiring methods with entirely nonmetallic-
sheaths, flexible cords and nonmetallic raceways. Correct Answer: True

Think plastic boxes. Read the 2 exceptions in this section. Review Tables E3904.6(1) through
E3904.6(10)

E3905.3 Nonmetallic boxes.

In calculating box fill each No. 12 AWG conductor shall require ___ cubic inches free space
within the box. Correct Answer: 2.25 cu. in.

Review Table E3905.13.1 and Table E3905.13.2.1

E3905.12.2.1 Volume Allowance Required Per Conductor.

Unused Openings in cabinets and panel boards shall be effectively ____ to afford protection
equivalent to that of the wall of the cabinet. Correct Answer: Closed

This means you can not have any open knockouts.

E3906.4 Unused openings.

The ____ shall not be considered as an effective ground-fault current path. Correct Answer:
Earth

E3908.5 Earth as a ground-fault current path.

Switches shall not be more than ____ feet, ____ inches above the floor or working platform,
when the switch is in its highest position. Correct Answer: 6 ft., 7 in.

Also applies to circuit breakers used as switches.

E4001.6 Access.

Receptacles installed on 15- and 20- ampere-rated branch circuits shall be of the ____ type.
Correct Answer: Grounding

Written for

Institution
Course

Document information

Uploaded on
November 4, 2022
Number of pages
6
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$8.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
HIGHFLYER Yale School Of Medicine
Follow You need to be logged in order to follow users or courses
Sold
288
Member since
4 year
Number of followers
263
Documents
1825
Last sold
8 months ago

4.0

82 reviews

5
43
4
16
3
11
2
5
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions