Storm drainage sump pumps shall be of a capacity and head appropriate to _______ use requirements. - anticipated Electrical services within the scope of the IRC are limited to _____-volt, 0- to _____- ampere, single-phase systems. - 120/240 & 400 Boiler pressure-relief valve discharge shall be pipes to drains by gravity to within _____ inches of the floor or to an open receptor. - 18 Polyethylene tubing for hydronic piping systems shall be installed with _____ ______ joints. - heat fusion The maximum amount of fuel oil stored above ground or inside a building shall be _____ gallons. - 660 (The supply tank shall be supported on rigid noncombustible supports to prevent settling or shifting) Vent piping on oil tanks shall be not smaller than _____-inch pipe. - 1 1/4 Oil tank vent piping shall terminate outside of building at a point not less than _____ feet, measured vertically or horizontally, from any building opening. - 2 Components of a solar thermal energy system that might be subject to pressure drops below atmospheric pressure during operations shall be protected by a _____-_____ _____. - vacuum-relief valve The minimum unobstructed total area of the outside and return air ducts or openings to a forced air warm-air FURNACE shall not be less than _____ square inches for each 1000 Btu/h output rating. - 2 (This also applies to supply ducts.)

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

2022 IRC Exam Prediction with COMPLETE SOLUTION | 161
Questions with 100% Correct Answers
Storm drainage sump pumps shall be of a capacity and head appropriate to _______ use
requirements. Correct Answer: anticipated

Electrical services within the scope of the IRC are limited to _____-volt, 0- to _____- ampere,
single-phase systems. Correct Answer: 120/240 & 400

Boiler pressure-relief valve discharge shall be pipes to drains by gravity to within _____ inches
of the floor or to an open receptor. Correct Answer: 18

Polyethylene tubing for hydronic piping systems shall be installed with _____ ______ joints.
Correct Answer: heat fusion

The maximum amount of fuel oil stored above ground or inside a building shall be _____
gallons. Correct Answer: 660 (The supply tank shall be supported on rigid noncombustible
supports to prevent settling or shifting)

Vent piping on oil tanks shall be not smaller than _____-inch pipe. Correct Answer: 1 1/4

Oil tank vent piping shall terminate outside of building at a point not less than _____ feet,
measured vertically or horizontally, from any building opening. Correct Answer: 2

Components of a solar thermal energy system that might be subject to pressure drops below
atmospheric pressure during operations shall be protected by a _____-_____ _____. Correct
Answer: vacuum-relief valve

The minimum unobstructed total area of the outside and return air ducts or openings to a forced
air warm-air FURNACE shall not be less than _____ square inches for each 1000 Btu/h output
rating. Correct Answer: 2 (This also applies to supply ducts.)

Domestic clothes dryer transition ducts shall be metal and limited to a single length not to exceed
_____ feet. Correct Answer: 8 (Transition ducts shall not be concealed within construction.)

What size are fuel-gas-fired domestic clothes dryer ducts? Correct Answer: 4 inches

The lowest portion of a gas floor furnace shall have not less than ______-inch clearance from
grade level. Correct Answer: 6 (Except where the lower 6-inch portion of the floor furnace is
sealed by the manufacturer to prevent entrance of water, the minimum clearance shall be reduced
to not less than 2 inches.)

Vent connectors for draft-hood-equipped appliances shall not be _____ than the draft hood outlet
diameter. Correct Answer: smaller

, A Type B-W gas vent shall terminate at least _____ feet in vertical height above the bottom of
the wall furnace. Correct Answer: 12

A Type B or a Type L gas vent shall terminate at least _____ feet in vertical height above the
highest connected APPLIANCE DRAFT HOOD or FLUE COLLAR. Correct Answer: 5

Gas APPLIANCE shutoff valves shall be located in the same room as the APPLIANCE and not
further than _____ feet from the APPLIANCE. Correct Answer: 6 (Each appliance shall be
provided with a shutoff valve separate from the appliance.)

Fuel gas appliance connectors shall not exceed an overall length of _____ feet. Correct Answer:
6

Gas vents over 12 inches in size shall terminate not less than _____ feet above the highest point
where they pass through the roof. Correct Answer: 2 (Amd at least 2 feet higher than any
portion of a building within 10 feet)

Underground fuel gas PIPING SYSTEMS shall be installed a minimum depth of _____ inches
below grade. Correct Answer: 12 (Except that individual lines to outside lights, grills or other
appliances shall be installed a minimum of 8 inches below grade, provided it is not subject to
physical damage.)

Shield plates, when required to cover the area of concealed gas piping, shall be a minimum
_____ gage. Correct Answer: No. 16

Where gas piping is concealed and run within _____ inches from the framing member face to
which the membranes will be attached it shall be protected by shield plates. Correct Answer: 1
1/2

Fuel gas PIPING installed across roof surfaces shall be elevated not less than _____ inches
above the roof surface. Correct Answer: 3 1/2

BTU is the abbreviation for _____ _____ _____, which is the quantity of heat required to raise
the temperature of 1 pound of water 1°F. Correct Answer: British Thermal Unit

When doing a water test on DWV systems during rough-in plumbing, each section shall be filled
with water to a point not less than _____ feet above the highest fitting in that section. Correct
Answer: 5 (Water shall be held in the section under test for 15 minutes. The system shall prove
leak free by visual inspection.)

When doing an air test on DWV systems during rough-in plumbing, the portion under test shall
be maintained at _____ psi for _____ minutes. Correct Answer: 5 & 15

Water service pipe shall be installed not less than _____ inches deep and not less than _____
inches below frost line. Correct Answer: 12 & 6

Geschreven voor

Instelling

Documentinformatie

Geüpload op
4 november 2022
Aantal pagina's
13
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
HIGHFLYER Yale School Of Medicine
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
288
Lid sinds
4 jaar
Aantal volgers
263
Documenten
1825
Laatst verkocht
8 maanden geleden

4.0

82 beoordelingen

5
43
4
16
3
11
2
5
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen