A Balancing Authority notices that Operating Reserve has steadily declined throughout the hour. What is the most likely cause? a) Loss of a large generator in the area b) An inaccurate load forecast c) Loss of a major transmission line d) A malfunction of EMS - ANSWER b) An inaccurate load forecast Balancing Area A notices that the Interconnection frequency is 59.94 Hz and their ACE is 0. Which of the following could be the cause of this reading? a) A net under-generation in Balancing Area A b) A net under-generation in the Interconnection c) A loss of load in Balancing Area A d) A loss of load in the Interconnection - ANSWER b) A net under-generation in the Interconnection What is the penalty for a Balancing Authority violating the Disturbance Control Standard? a) Must carry additional Contingency Reserve b) Must develop a correction action plan c) Must re-evaluate and change its Frequency Bias Setting d) Must increase its Regulating Reserve - ANSWER a) Must carry additional Contingency Reserve Your ACE is a large negative value and system frequency is 59.80 Hz. Your AGC system is pulsing your units down. What should you do? a) Place AGC in flat frequency control b) Place AGC in flat tie line control c) Suspend AGC and investigate d) Do nothing as this is normal - ANSWER c) Suspend AGC and investigate When two identical generating units are operated in parallel on governor control, and on machine has a 5% droop and the other has a 10% droop, the unit with the greater (10%) governor droop will: a) Respond less to frequency deviations b) Respond more to frequency deviations

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

KNOWN NERC EXAM QUESTIONS complete solution
with Questions and Answers 2023


A Balancing Authority notices that Operating Reserve has steadily declined throughout
the hour. What is the most likely cause?

a) Loss of a large generator in the area
b) An inaccurate load forecast
c) Loss of a major transmission line
d) A malfunction of EMS - ANSWER b) An inaccurate load forecast

Balancing Area A notices that the Interconnection frequency is 59.94 Hz and their ACE
is 0. Which of the following could be the cause of this reading?

a) A net under-generation in Balancing Area A
b) A net under-generation in the Interconnection
c) A loss of load in Balancing Area A
d) A loss of load in the Interconnection - ANSWER b) A net under-generation in the
Interconnection

What is the penalty for a Balancing Authority violating the Disturbance Control
Standard?

a) Must carry additional Contingency Reserve
b) Must develop a correction action plan
c) Must re-evaluate and change its Frequency Bias Setting
d) Must increase its Regulating Reserve - ANSWER a) Must carry additional
Contingency Reserve

Your ACE is a large negative value and system frequency is 59.80 Hz. Your AGC
system is pulsing your units down. What should you do?

a) Place AGC in flat frequency control
b) Place AGC in flat tie line control
c) Suspend AGC and investigate
d) Do nothing as this is normal - ANSWER c) Suspend AGC and investigate

When two identical generating units are operated in parallel on governor control, and on
machine has a 5% droop and the other has a 10% droop, the unit with the greater
(10%) governor droop will:

a) Respond less to frequency deviations
b) Respond more to frequency deviations

, c) Respond the same to frequency deviations
d) Not adjust for frequency changes - ANSWER a) Respond less to frequency
deviations

On a radial transmission system a generator has a capacity of 600 MWs. The Droop
characteristic is at 5% and the generator is currently loaded at 300 MWs. If frequency
suddenly drops to 59.3 Hz, what would be the total generator output?

a) 350
b) 400
c) 440
d) 600 - ANSWER c) 440

What is the main purpose of the Frequency Bias Setting in the ACE equation?

a) Control frequency to 60 Hz for the entire Interconnection
b) Assist with arresting frequency deviations
c) Restore frequency to 60 Hz after a disturbance
d) maintains frequency between 59.95 and 60.05 Hz - ANSWER b) Assist with arresting
frequency deviations

A Balancing Authority has a Frequency Bias Setting of -200 MW/.1Hz. What is the
Balancing Authority's Frequency Response for a frequency of 59.95 Hz?

a) 10 MWs
b) 50 MWs
c) 100 MWs
d) 200 MWs - ANSWER c) 100 MWs

Scheduled Interchange is 250 MWs and Actual Interchange is 285 MWs. The Bias
Setting is 35 MW/.1Hz and frequency is 60.00 Hz with no time error correction in effect.
Frequency suddenly drops to 59.80 Hz. What does ACE indicate after the disturbance?

a) 70 MW under-generating
b) 70 MW over-generating
c) 35 MW under-generating
d) 35 MW over-generating - ANSWER d) 35 MW over-generating

Inadvertent energy accumulation occurs due to a difference in Net Actual Interchange
and Net Interchange Schedule over time. This energy accumulation can be paid back
unilaterally by adjusting delivery of power:

a) During off-peak periods
b) During periods corresponding to those in which the inadvertent energy was
accumulated
c) On weekends

Geschreven voor

Vak

Documentinformatie

Geüpload op
26 januari 2023
Aantal pagina's
7
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$9.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
nursingismylife West Virginia University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
260
Lid sinds
3 jaar
Aantal volgers
174
Documenten
9125
Laatst verkocht
4 dagen geleden

3.6

38 beoordelingen

5
14
4
12
3
3
2
1
1
8

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen