Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

SPI Practice (ARDMS A & B)

Rating
-
Sold
-
Pages
15
Grade
A+
Uploaded on
28-02-2023
Written in
2022/2023

SPI Practice (ARDMS A & B) C What is dynamic aperture? A.aperture that varies with transmit frequency B.aperture that decreases as a function of time C.aperture that increases with increasing focal length D.aperture that changes as a function of frame rate A to which acoustic variable is penetration depth inversely related? A.frequency B.wavelength C.period D.propagation speed B which imaging mode requires a broadband transducer? A.continuous wave doppler B.Pulsed wave doppler C.color flow imaging D.harmonic imaging B what is the doppler shift frequency? A.recieved ultrasound frequency multiplied by the transmitted ultrasound frequency B.difference between the transmitted ultrasound frequency and the received ultrasound frequency C.sum of the transmitted and received ultrasound frequencies D.ratio of the transmitted ultrasound frequency to the received ultrasound frequency A what is the potential effect of increasing the pulse repetition frequency(PRF)? A.Depth ambiguity B.Decreased frame rate C.Poor spatial resolution D.Decreased penetration B what is an advantage of using pulsed wave doppler compared to continuous wave doppler? A.higher echo sensitivity B.ability to select sample depth C.decreased display of aliasing D.improved temporal resolution D what affects the beam width in the near field? A.Pulse repetition frequency B.Pulse duration C.Frame rate D.Transducer aperture D what is the advantage of using pulsed-wave doppler versus continuous-wave doppler? A.allows measurement of higher velocities B.increases range ambiguity C.reduces the potential for aliasing D.provides depth specificity D which parameter is target group C evaluating based on the image? A.dead zone B.dynamic range C.axial resolution D.Horizontal distance accuracy A In this image, which target group is used to evaluate dead zone? C which ultrasound parameter directly affects an ultrasound beam's intensity? A.TGC B.operating frequency C.Output power D.Frame rate D the center frequency of a transducer depends primarily upon which characteristics of the crystal? A.width B.length C.spacing D.thickness C which factor limits image frame rate? A.transducer operating frequency B.Sample volume size C.Speed of sound in tissue D.Spatial pulse length A when using a 5MHZ transducer, in which tissue is the ultrasound wavelength shortest? A.fat B.blood C.bone D.muscle D which term describes the averaging together of scan lines from multiple angles to create one image? A.harmonic imaging B.realtime three dimensional imaging C.elastography D.spatial compounding A which variable can cause an acoustic shadow artifact? A.small acoustic impedance mismatch B.refraction C.perpendicular incidence D.low attenuation B what does coded excitation improve in addition to penetration? A.lateral resolution B.signal-to-noise ratio C.frame rate D.dynamic range A how is lateral resolution determined for a pulsed-echo system using a tissue-mimicking test object? A.by observing spaces between reflectors perpendicular to the beam B.by observing spaces between reflectors along the beam path C.by observing position of deepest visible reflector along the beam path D.by observing position of deepest visible reflector perpendicular to the beam path A which variable caused the color change from blue to red of the vessel in this image? A.change in vessel direction B.color scale set to low C.turbulent flow D.severe stenosis C which artifact is indicated by the arrows in this image? A.shadow produced by the diaphragm B.acoustic enhancement C.comet tail D.mirror image D which control improves the effects of attenuation? A.dynamic range B.pulse inversion C.multiple focal zones D.time gain compensation A which doppler angle to flow results in the greatest absolute doppler shift? A.0 degrees B.15 degrees C.45 degrees D.60 degrees A what term describes blood flow changes in response to respiration? A.phasic B.parabolic C.spontaneous D.pulsatile B an increase in which parameter will improve the accuracy of velocity measurements with autocorrelation? A.color field of view B.packet size C.wall filtering D.transmitted frequency C which harmonic imaging, how does echo frequency relate to transmitted frequency? A.half the transmitted frequency B.equal to the transmitted frequency C.twice the transmitted frequency D.four times the transmitted frequency B Which change would minimize the artifact observed in this image, assuming the pulse repetition frequency is at its maximum limit? A.adjust the sweep speed B.adjust the baseline C.increasing dynamic range D.increasing the transmitted frequency D which parameter is most likely to affect spat

Show more Read less
Institution
Course

Content preview

SPI Practice (ARDMS A & B)
C

What is dynamic aperture?
A.aperture that varies with transmit frequency
B.aperture that decreases as a function of time
C.aperture that increases with increasing focal length
D.aperture that changes as a function of frame rate

A

to which acoustic variable is penetration depth inversely related?
A.frequency
B.wavelength
C.period
D.propagation speed

B

which imaging mode requires a broadband transducer?
A.continuous wave doppler
B.Pulsed wave doppler
C.color flow imaging
D.harmonic imaging

B

what is the doppler shift frequency?
A.recieved ultrasound frequency multiplied by the transmitted ultrasound frequency
B.difference between the transmitted ultrasound frequency and the received ultrasound frequency
C.sum of the transmitted and received ultrasound frequencies
D.ratio of the transmitted ultrasound frequency to the received ultrasound frequency

A

what is the potential effect of increasing the pulse repetition frequency(PRF)?
A.Depth ambiguity
B.Decreased frame rate
C.Poor spatial resolution
D.Decreased penetration

B

what is an advantage of using pulsed wave doppler compared to continuous wave doppler?
A.higher echo sensitivity
B.ability to select sample depth

, C.decreased display of aliasing
D.improved temporal resolution

D

what affects the beam width in the near field?
A.Pulse repetition frequency
B.Pulse duration
C.Frame rate
D.Transducer aperture

D

what is the advantage of using pulsed-wave doppler versus continuous-wave doppler?
A.allows measurement of higher velocities
B.increases range ambiguity
C.reduces the potential for aliasing
D.provides depth specificity

D

which parameter is target group C evaluating based on the image?
A.dead zone
B.dynamic range
C.axial resolution
D.Horizontal distance accuracy




A

In this image, which target group is used to evaluate dead zone?




C

which ultrasound parameter directly affects an ultrasound beam's intensity?
A.TGC
B.operating frequency

Written for

Course

Document information

Uploaded on
February 28, 2023
Number of pages
15
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$9.89
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CertifiedGrades Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
145
Member since
3 year
Number of followers
61
Documents
8740
Last sold
3 weeks ago
High Scores

Hi there! Welcome to my online tutoring store, your ultimate destination for A+ rated educational resources! My meticulously curated collection of documents is designed to support your learning journey. Each resource has been carefully revised and verified to ensure top-notch quality, empowering you to excel academically. Feel free to reach out to consult with me on any subject matter—I'm here to help you thrive!

3.9

38 reviews

5
21
4
6
3
2
2
3
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions