Fire Inspector 2: Combined Fire protection engineers have established _____ PSI as a minimum required residual pressure when computing the available water for flow test results. Ans- 20psi The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM. Ans- 500 - 1500 gpm A fire pump serving a standpipe system should be tested ______ Ans- weekly A fire department pumper can effectively supply around ______ feet in a high rise building depending on hydrant pressure and other factors. Ans- 450 feet Class 2 standpipe is for __________ use Ans- occupational Standpipe classifications: 1. 2 3. Ans- 1. Fire Dept only 2. Occupant use only 3. Both Fire Dept and Occupant use NFPA 13D requires _______ for any sprinkler Ans- 18 GPM Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi residual pressure at the highest outlet. Ans- 500 Stored material should not be stacked closer than ____ inches to a sprinkler head Ans- 18 inches _______ system is used when it is especially important that water damage be prevented, even if the sprinkler pipes should break accidentally. Ans- Preaction Fire dampers are usually activated by _____ ______ Ans- fusible links ________ detectors are - activated by heat (expansion) and are self-resetting (automatic) Ans- Bimetallic Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and propane Ans- B Pressure tanks should be filled ______ of water with ____ psi Ans- 2/3; 75psi Fire extinguishers 40lbs should be mounted no higher than ______ feet from the floor Ans- 3 ½ _______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate and water Ans- Wet chemical _______ _______ extinguishers limitations are the clean-up Ans- Dry chemical _____ ______ agents are difficult to clean up due to water repellant Ans- Dry chemical When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers must be at least ______ feet apart Ans- 20 feet Freeboard should never be more than ___ inches Ans- 6 _________ ________ is wood chips glued together to make flat sheets Ans- Particle board The maximum size for an approved safety can is ___ gallons Ans- 5 Open burning fire should not be allowed within ______ feet of a structure Ans- 50 Approved incinerators for burning trash should be at least _____ feet from a structure Ans- 15 Fire in an approved burn container should not be within ____ feet of a structure Ans- 25 Explosives are class ___ hazardous material Ans- 1 TNT/dynamite are considered ______ _________ Ans- high explosives Explosives must be packed at least ______ feet from the magazine Ans- 50 __________ _________ prevents fire growth Ans- Solid staking (piling) Rack storage requires sprinklers within all the racks exceeding _____ feet Ans- 25 __________ _________ is the heating of an organic substance without the addition of external heat Ans- Spontaneous combustion ________ is the transfer of heat energy from one body to another Ans- Conduction Fire doubles its intensity with each ____ degrees increase Ans- 18 Ordinary combustion produces _____ BTU per 1lb Ans- 8,000 BTU's ______ ________ test flame spread ratings based on: 0-asbestos cement board and 100-red oak wood Ans- Steiner tunnel Ohms measures ___________ Ans- resistance Amps measure ________ _________ Ans- electrical current Volts measures _______ Ans- voltage NFPA _____ addresses ventilation control and fire protection of commercial cooking operation AnsNFPA 96 Balcony or mezzanine with occupant loads greater than 100 shall have __ exits/means of egress provided. Ans- 2 Assembly occupancies with occupant load of ______ shall be protected by approved, supervised automatic sprinkler system. Also shall have an alarm system Ans- 300

Show more Read less
Institution
Course

Content preview

Fire Inspector 2: Combined
Fire protection engineers have established _____ PSI as a minimum required residual pressure when
computing the available water for flow test results. Ans- 20psi



The most common gallonage rating for horizontal shaft pumps in use today are _____ - _____ GPM.
Ans- 500 - 1500 gpm



A fire pump serving a standpipe system should be tested ______ Ans- weekly



A fire department pumper can effectively supply around ______ feet in a high rise building depending
on hydrant pressure and other factors. Ans- 450 feet



Class 2 standpipe is for __________ use Ans- occupational



Standpipe classifications:

1.

2

3. Ans- 1. Fire Dept only

2. Occupant use only

3. Both Fire Dept and Occupant use



NFPA 13D requires _______ for any sprinkler Ans- 18 GPM



Minimum water supply for a class 1 or 3 standpipe system is _____ gpm for at least 30mn with 65psi
residual pressure at the highest outlet. Ans- 500



Stored material should not be stacked closer than ____ inches to a sprinkler head Ans- 18 inches



_______ system is used when it is especially important that water damage be prevented, even if the
sprinkler pipes should break accidentally. Ans- Preaction

,Fire dampers are usually activated by _____ ______ Ans- fusible links



________ detectors are - activated by heat (expansion) and are self-resetting (automatic) Ans- Bimetallic



Class ____ fires: fire of flammable and combustible liquids and gases such as gasoline, kerosene and
propane Ans- B



Pressure tanks should be filled ______ of water with ____ psi Ans- 2/3; 75psi



Fire extinguishers >40lbs should be mounted no higher than ______ feet from the floor Ans- 3 ½



_______ _______ is an aqueous solution of either potassium carbonate and water or potassium acetate
and water Ans- Wet chemical



_______ _______ extinguishers limitations are the clean-up Ans- Dry chemical



_____ ______ agents are difficult to clean up due to water repellant Ans- Dry chemical



When liquid propane gas is stored in the same area as flammable or combustible liquid, the containers
must be at least ______ feet apart Ans- 20 feet



Freeboard should never be more than ___ inches Ans- 6



_________ ________ is wood chips glued together to make flat sheets Ans- Particle board



The maximum size for an approved safety can is ___ gallons Ans- 5



Open burning fire should not be allowed within ______ feet of a structure Ans- 50

, Approved incinerators for burning trash should be at least _____ feet from a structure Ans- 15



Fire in an approved burn container should not be within ____ feet of a structure Ans- 25



Explosives are class ___ hazardous material Ans- 1



TNT/dynamite are considered ______ _________ Ans- high explosives



Explosives must be packed at least ______ feet from the magazine Ans- 50



__________ _________ prevents fire growth Ans- Solid staking (piling)



Rack storage requires sprinklers within all the racks exceeding _____ feet Ans- 25



__________ _________ is the heating of an organic substance without the addition of external heat
Ans- Spontaneous combustion



________ is the transfer of heat energy from one body to another Ans- Conduction



Fire doubles its intensity with each ____ degrees increase Ans- 18



Ordinary combustion produces _____ BTU per 1lb Ans- 8,000 BTU's



______ ________ test flame spread ratings based on: 0-asbestos cement board and 100-red oak wood
Ans- Steiner tunnel



Ohms measures ___________ Ans- resistance



Amps measure ________ _________ Ans- electrical current

Written for

Course

Document information

Uploaded on
March 27, 2023
Number of pages
24
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.39
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
CertifiedGrades Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
145
Member since
3 year
Number of followers
61
Documents
8740
Last sold
3 weeks ago
High Scores

Hi there! Welcome to my online tutoring store, your ultimate destination for A+ rated educational resources! My meticulously curated collection of documents is designed to support your learning journey. Each resource has been carefully revised and verified to ensure top-notch quality, empowering you to excel academically. Feel free to reach out to consult with me on any subject matter—I'm here to help you thrive!

3.9

38 reviews

5
21
4
6
3
2
2
3
1
6

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions