Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

EPA 608 Certification 2023 with verified questions and answers

Rating
-
Sold
-
Pages
5
Grade
A+
Uploaded on
29-03-2023
Written in
2022/2023

What date was the sale of CFC's & HCFC's restricted to technicians certified in refrigerant recovery? November 14, 1994 Section 608 of the Federal Clean Air Act requires technicians to what? Recover all refrigerants. The objective of the Clean Air Act is to protect what? The earth's stratosphere. HFC's HydroFlouroCarbon's CFC's ChloroFluoroCarbon's ODP Ozone Depletion Potential Which international treaty agreement was the basis for Section 608? The Montreal Protocol. Depletion of the ozone in the stratosphere is know to cause what 6 things? 1.Crop losses 2.Increases in eye diseases 3.Skin Cancer 4.Reduced marine life 5.Deforestation 6.Increased ground level ozone What happens when CFC or HCFC molecules get in the stratosphere & free atoms of Chlorine are set free? These atoms attack Ozone Molecules causing the formation of Chlorine Monoxide (CLO), after colliding with another Ozone Molecule, causes 2 Oxygen (O2) molecules to be made & leaving an atom of chlorine to act as "Free Agent" starting the process over until 100,000 molecules of Ozone are destroyed by just one atom of chloride. What date was recovery equipment required to be certified by a lab, & achieve higher evacuation levels, & have low loss fittings? November 15, 1993 On what date was technician certification required? November 14, 1994 What date was CFC's phased out of production? December 31, 1995 What is EPA 608 Type I certification? Persons who maintain, service, repair, or dispose of small appliances (containing 5 pounds of refrigerant (or less). What is EPA 608 Type II certification? Persons who maintain, service, repair, or dispose of high and very high pressure appliances. Except small appliances and motor vehicle air conditioning systems. What is EPA 608 Type III certification? Persons who maintain, service, repair, or dispose of low pressure appliances. What is EPA 608 Universal certification? Persons who maintain, service, repair, or dispose of both low and high pressure equipment, as well as appliances. HCFC's HydroChloroFluoroCarbons What are HydroChloroFluoroCarbons? Commonly known as HCFC's, they are a group of man-made compunds containing hydrogen, chlorine, fluorine, and carbon. A recovery cylinder must not be filled more than ___ % of it's capacity by weight? 80% How should refrigerant cylinders be shipped? Up-right with proper DOT classification tags. What oil MUST be used with ALL HFC's for HVAC/Refrigeration but will also work with CFC's and HCFC's. Polyolester HCFC's have very low atmospheric concentrations measured in parts per? Trillion All cooling systems containing more than 50 lbs. of refrigerant must be repaired when the annual leak rate exceeds___? 15% Mineral Oils are used with? All CFC's Alkebenzene is used alone or as an additive for? HCFC's (Will also work with CFC's) POE Polyolester What is the definition of a Type I Appliance? A small appliance that is manufactured, charged, and hermetically sealed in a factory with 5 Lbs. of refrigerant or less. What is the definition of a Type II Appliance? High pressure or very high pressure appliances except for small appliances and motor vehicle air conditioning. Refrigeration systems containing more than 5 Lbs. of high or very high pressure refrigerants. What is the definition of a Type III Appliance? Low pressure equipment like low pressure chillers. All refrigerants are assumed to be a single chemical if they are numbered what? 1-399 and 600 and above. What is an Azeotrope? A mixture of two or more liquids in such a ratio that it's composition cannot be changed by vaporizing it. Azeotrope's are numbered what? 500 to 599 What is fractionation? When the refrigerant leaks, it leaks out in different rates due to the different pressures. What is Temperature Glide? When the temperature of the vaporizing refrigerant changes, even though the pressure remains the same. What are the two basic types of recovery devices? Self-Contained and System-Dependent. System-Dependent devices may only be used on appliances containing how much refrigerant? 15 Lbs of refrigerant or less What MUST be placed on a refrigerant cylinder being returned for reclaiming. A refrigerant label. After completing the transfer of liquid refrigerant between a recovery unit and a refrigeration system, you should guard against what? Trapping liquid refrigerant between the service valves. When pressurizing a system with nitrogen, you should always? Charge through a pressure regulator. What are the three "R's"? Recover, Recycle, and Reclaim. In relation to the three "R's" what is Recover? To remove refrigerant in any condition from a system and store it in an external approved container. In relation to the three "R's" what is Recycle? To clean refrigerant for reuse by seperating the oil from the refrigerant and removing moisture from the refrigerant by passing it through one or more filter dryers. Can Recycled refrigerant be resold? It cannot be re-sold but it can be re-used. In relation to the three "R's" what is Reclaim? To process refrigerant to a level equal to new (virgin) product specifications as determined by chemical analysis. Can Reclaimed refrigerant be resold? Yes, but must meet the standard set forth in ARI 700 before it can be resold. What chemical has been found in the stratosphere indicating ozone depletion? Chlorine Monoxide (CLO) What are 5 Type I appliances? 1.Household refrigerators 2.Household freezers 3.Room air conditioners 4.Water Coolers 5.Drinking fountains What are 6 Type II appliances? 1.Walk-in coolers 2.Walk-in freezers 3.Reach-in refrigerators 4.Reach-in freezers 5.Residential & Commercial comfort cooling systems 6.Ice machines What is an example of a Type III appliance? Low pressure chiller. When is "Dew Point" used? When calculating Superheat. When is "Bubble Point" used? When calculating Sub-cooling. What does the EPA require on all Type I equipment that uses Class I or Class II refrigerants. EPA requires a service aperature (process stub). TXV Thermostatic Expansion Valve The EPA considers a major repair to be the replacement of what 4 items? 1.Evaporator 2.Condenser 3.Compressor 4.Auxillary Heat Exchanger When the refrigerant is put back into a Type III chiller, following recovery and system repair, where is it added? The charging valve on the evaporator. What method is used to find suspected water tube leaks in chillers? Hydrostatic (tube) test What temperature should be attained when removing oil from a low pressure system to ensure a lower level of refrigerants in the oil? 130-Degrees F The typical design burst pressure for a rupture disc is what? 15 PSIG Excessive moisture collection in the purge unit can indicate what? Tube Leakage Vacuum pumps need to be capable of pulling what level of vacuum? 500 microns All refrigeration systems containing more than 50 lbs. of refrigerant must be repaired when the annual leak rate exceeds___? 35% The most efficient method of leak checking a charged low-pressure system is to use? Controlled hot water or heater blankets. Systems with open drive compressors are prone to leak where? At the shaft seal. What does ASHRAE standard 15 require? A refrigerant monitor that will sound and alarm and automatically start a ventilation system in equipment rooms before the refrigerant concentration reaches the TLV-TWA. TLV-TWA Threshold Limit Value, Time Weighted Average A-1 Group Refrigerants only require what? Oxygen Deprivation Sensor All "B" rated refrigerants require what? "Refrigerant Specific" Mechanical Room Sensor. What are Cooling Towers? They are heat removal devices used to transfer process waste heat to the atmosphere. What is the maximum test pressure to use for pressurizing Type III centrifugal systems with nitrogen? 10 psig Enough vapor has entered the system and you may begin charging liquid refrigerant when the refrigerant saturation temperature increases to? 36F

Show more Read less
Institution
EPA 608 Certification
Course
EPA 608 Certification









Whoops! We can’t load your doc right now. Try again or contact support.

Written for

Institution
EPA 608 Certification
Course
EPA 608 Certification

Document information

Uploaded on
March 29, 2023
Number of pages
5
Written in
2022/2023
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$9.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Arthurmark Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
45
Member since
4 year
Number of followers
39
Documents
1422
Last sold
7 months ago

3.7

9 reviews

5
5
4
0
3
2
2
0
1
2

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions