SSEPs Practice Questions and Answers 2023 with complete solution When recording a posterior tibial nerve SSEP, the Fpz ‐ C5s channel records A- subcortical near‐field potentials B- the Erb's point potential C- stationary lumbar potentials D- subcortical far ‐ field potentials D- subcortical far ‐ field potentials In the 10 ‐ 20 system of electrode placement, the point 20% (of the nasion‐inion distance) anterior to Cz is called A- Fz B- Fpz C- C1 D- Pz A- Fz An electrode measured 20% lateral to Cz on the right using 10 ‐ 20 system is A- T3 B- A2 C- C4 D- C3 C- C4 P14 is a far ‐ field, subcortically generated response which probably reflects A- caudal medial lemniscal activity B- activity from the precentral gyrus C- passage of the afferent volley D- a stationary cervical potential A- caudal medial lemniscal activity If over three hours the PTN cortical response attenuates while subcortical is stable: A- Do a wake ‐ up test B- Stimulate peroneal nerve C- Keep monitoring subcorticals D- Inform the surgeon monitoring is no longer reliable C- Keep monitoring subcorticals In general, filter settings for SEP recordings A- should always be 30 ‐ 3000 Hz B- can be narrower for cortical than peripheral responses C- can be narrower for peripheral than cortical responses D- should always include 60 Hz band pass filters B- can be narrower for cortical than peripheral responses The initial waveform recorded of a near ‐ field PTN cortical potential is A- of very low amplitude due to the significant distance between the generator and recording electrode B- positive due to electrotonic depolarization of the membrane under the recording electrode

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

SSEPs Practice Questions and Answers 2023 with complete
solution
When recording a posterior tibial nerve SSEP, the Fpz ‐ C5s channel records
A- subcortical near‐field potentials
B- the Erb's point potential
C- stationary lumbar potentials
D- subcortical far ‐ field potentials
D- subcortical far ‐ field potentials
In the 10 ‐ 20 system of electrode placement, the point 20% (of the nasion ‐inion
distance) anterior to Cz is called
A- Fz
B- Fpz
C- C1
D- Pz
A- Fz
An electrode measured 20% lateral to Cz on the right using 10 ‐ 20 system is
A- T3
B- A2
C- C4
D- C3
C- C4
P14 is a far ‐ field, subcortically generated response which probably reflects
A- caudal medial lemniscal activity
B- activity from the precentral gyrus
C- passage of the afferent volley
D- a stationary cervical potential
A- caudal medial lemniscal activity
If over three hours the PTN cortical response attenuates while subcortical is stable:
A- Do a wake ‐ up test
B- Stimulate peroneal nerve
C- Keep monitoring subcorticals
D- Inform the surgeon monitoring is no longer reliable
C- Keep monitoring subcorticals
In general, filter settings for SEP recordings
A- should always be 30 ‐ 3000 Hz
B- can be narrower for cortical than peripheral responses
C- can be narrower for peripheral than cortical responses
D- should always include 60 Hz band pass filters
B- can be narrower for cortical than peripheral responses
The initial waveform recorded of a near ‐ field PTN cortical potential is
A- of very low amplitude due to the significant distance between the generator and
recording electrode
B- positive due to electrotonic depolarization of the membrane under the recording
electrode

,C- always obscured by stimulus artifact
D- negative due to depolarization of membrane potentials
B- positive due to electrotonic depolarization of the membrane under the recording
electrode
A patient is admitted to the operating room diagnosed with a herniated cervical disc at C
5/6. The most appropriate nerve(s) to monitor during the resulting surgical procedure
would be the:
A- ulnar nerve
B- median and posterior tibial nerves
C- median and auditory nerves
D- peroneal and ulnar nerves
B- median and posterior tibial nerves
Somatosensory evoked potentials are most likely to be highly variable and less reliable
in patients with
A- myopathy
B- neuromuscular disease
C- a history of nicotine abuse
D- alcoholism
B- neuromuscular disease
Lower extremity SEPs are transmitted through the
A- gracilis nucleus
B- the superior olivary complex
C- cuneate nucleus
D- the lateral lemniscus
A- gracilis nucleus
Stimulation of the motor pathway at the spinal cord can be achieved with little
movement in the surgical field by
A- decreasing muscle relaxants
B- increasing the stimulation duration
C- slowing the stimulation rate
D- increasing the stimulation rate enough to produce muscle tetany
D- increasing the stimulation rate enough to produce muscle tetany
Which of the following upper extremity somatosensory responses is considered a
"stationary potential"?
A- N18
B- P14
C- N13
D- N20
C- N13
The use of the 60 Hz notch filter is discouraged while recording because it can
A- filter slow activity, distorting the response
B- cause the recording electrodes to form a salt bridge
C- produce a risk to the patient
D- produce ringing activity that can contaminate the appearance of the response
D- produce ringing activity that can contaminate the appearance of the response

, When monitoring with SSEPs, dural or direct cord recordings are advantageous
because:
A- the waveforms better reflect cortical responses to stimulation
B- they present less discomfort to the patient than scalp leads
C- they have less chance of artifact during cauterization
D- the waveforms are higher in amplitude and require fewer averages
D- the waveforms are higher in amplitude and require fewer averages
Electrical amplitude of the SEP is
A- 1000 uV to 10,000 uV
B- 10 to 100 uV
C- 0.1 to 10 uV
D- 100 uV to 1000 uV
C- 0.1 to 10 uV
An advantage of referential, as opposed to bipolar recording of spinal cord
somatosensory evoked potentials, is
A- the ease of electrode placement
B- avoiding cancellation of the potentials as a result of recording from adjacent levels
C- the elimination of electromyographic artifact from the paraspinous muscles
D- less invasion of the surgical field
B- avoiding cancellation of the potentials as a result of recording from adjacent levels
What is the main advantage of asynchronous bilateral stimulation?
A- Less patient movement
B- Reduction of stimulus artifact
C- Differentiation of local vs. systemic effects
D- Faster data acquisition
C- Differentiation of local vs. systemic effects
Which of the following is the best monitoring strategy for a C7 fracture:
A- MN and PTN
B- Sural and saphenous
C- MN and peroneal
D- Ulnar and PTN
D- Ulnar and PTN
Median nerve SEP produces a wave at the brachial plexus designated
A- N20
B- P23
C- N9
D- N11
C- N9
The SEP reaches adult form and latency by
A- 6 months
B- birth
C- 18 months
D- 8 years
D- 8 years
SEP stimulating electrodes should be
A- placed with the negative electrode proximal

Geschreven voor

Vak

Documentinformatie

Geüpload op
30 maart 2023
Aantal pagina's
29
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
magdamwikash23 Western Governers University
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
114
Lid sinds
3 jaar
Aantal volgers
94
Documenten
5328
Laatst verkocht
1 dag geleden
Magda

NURSING STUDY GUIDES/EXAMS AND NOTES ALL VERIFIED BY EXPERTS All my uploaded documents, exams and essays are verified by relevant experts.I can assure an A or at least 90% if you use any of my documents.

3.9

14 beoordelingen

5
7
4
2
3
2
2
2
1
1

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen