A consultant needs to verify the make and model of the systems that will be imaged with
Foundation. The consultant does not have the Bill of Materials (BOM) available to review.
When should the consultant verify the make and model to prepare for the cluster
deployment?
A. Upon arriving on-site
B. When reviewing the Statement of Work (SOW)
C. During the Foundation process
D. While conducting the Tech Review Call
D. While conducting the Tech Review Call
Which Subnet is reserved for the internal connectivity within a Nutanix Cluster?
A. 192.168.5.0/24
B. 192.168.5.0/26
C. 192.168.254.0/24
D. 192.168.5.0/23
A. 192.168.5.0/24
A consultant is planning an installation and needs to collect configuration items to be said
during the install. The data needed from the customer are the IP Addresses, Gateway, DNS
server, and NTP Servers. Which Cluster Deployment document must be completed with
the customer?
A. Questionnaire
B. Operations Guide
C. Technical Checklist
D. Project Plan
A. Questionnaire
A consultant is writing an ESXi host via console without external network connectivity.
Which 2 IP's can be used to connect to the CVM? (Choose two)
A. 192.168.5.254
B. 192.168.5.1
C. 192.168.5.2
D. 192.168.5.253
A. 192.168.5.254
C. 192.168.5.2
,Which two components must be identified to validate that software compatibility
requirements are met for the Nutanix Cluster installation? (choose two)
A. AOS
B. Hypervisor
C. Guest OS
D. Firmware
A. AOS
B. Hypervisor
What is the minimum number of nodes required for a Nutanix Cluster to support
Replication Factor 3 (RF3) on a storage container?
A. 6
B. 5
C. 4
D. 3
B. 5
A Nutanix cluster has 10TB usable storage, the customer wants to create a 100GB data
store for ISO images to eliminate too much storage being consumed by unnecessary images.
Which setting should be used to accomplish this goal?
A. From Container Advanced Settings, configure 100GB for advertised capacity
B. From Container Advance Settings, configure 100GB for reserved capacity
C. From Container Advance Settings, turn on compression and deduplication
D. From Container Advanced Settings, enable erasure coding
A. From Container Advanced Settings, configure 100GB for advertised capacity
While preparing for a new four-node cluster installation the consultant has a Tech Review
Call with the customer. The hardware is as follows:
- 4 nodes in 1 Block
- 8 x 10 GbE Ports
- 4 x 1 GbE IPMI Ports
- Adequate Ethernet ports are available
- Ethernet cables are correct and available
- Adequate rack space is available
Which remaining team must be confirmed as available onsite?
A. Redundant 208v power
B. Fibre Channel Switches
C. Redundant 110v power
D. Crash Cart
A. Redundant 208v power
, A consultant needs to review the customer switch port configuration to identify any issues.
Other customer requirements are as follows:
- Leverage LACP
- Native VLAN will not be used
- Use Multiple Upstream switches
- Use VLANs 20-25 and 30
- LACP Failback has been Enabled
- vPC or MLAG has been configured
What must be included in a configuration that meets these requirements?
A. Native VLAN set to 30
Ports trunked to allow all necessary VLANs
B. Native VLANs set to VLAN 30
Ports in access mode to allow all necessary VLANs
C. Native VLANs set to default
Ports in access mode to allow all necessary VLANs
D. Native VLANs set to default
Ports trunked to allow all necessary VLANs
D. Native VLANs set to default
Ports trunked to allow all necessary VLANs
11. A customer has 2 NX-3460-G6 blocks. A consultant arrives at the customer site and
finds the following:
1 Rack with a total of 5U available
2 ToR switches with 14 total available ports
Dual PDUs with six available sockets
What will prevent the consultant from successfully installing the cluster?
A. Insufficient sockets for the power allocation. Rack space may not be continuous
B. Insufficient network ports for communication, insufficient sockets for power allocation
C. Insufficient network ports for communication. Rack space may not be continuous
D. Insufficient rack space for block installation. Insufficient sockets for power allocation
C. Insufficient network ports for communication. Rack space may not be continuous
A consultant is planning a new cluster installation and needs to locate the Shared IPMI
ports for the specific nodes that the customer has bought.
What document identifies the port in the support portal documentation?
A. Software Documentation
B. Hardware Replacement Documentation