UST Test Study Questions & Answers
| 160 Questions with 100% Correct
Answers | Verified| 41 Pages.
The regulations to enforce compliance of underground storage
tank systems in the state are found in?

a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - - b.)
California Code of Regulations; Title 23, Chapter 16

-By definition an "underground storage tank system" includes

a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and
containment system
c.) Only the tank
d.) Only tanks totally beneath the surface of the ground - - b.)
The tank, all connected piping, ancillary equipment and
containment system

(H&SC, Sec 25281(z))

-Under-dispenser containment was required for all UST systems
by ___________.

a.) December 31, 2003
b.) July 1, 1987
c.) January 1, 1984
d.) January 1, 2000 - - a.) December 31, 2003

CCR Title 23, Sec 2636(g)(C)

-According to California Law, UST systems installed after July 1,
2003, require a one-time ELD test to ensure that the tank is
product tight...

,a.) If the tank is located within one (1) mile of a public drinking
water well
b.) If the tank is located within 1000 feet of a public drinking
water well
c.) Unless the tank is equipped with secondary containment
d.) In all cases - - For ALL tanks before use (H&SC 25290.2 (I))
d.) In all cases

H&SC, Sec 25290.2(i)

-The written report submitted to the local agency after an
unauthorized release is required to include the following except:

a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - - b.) Cause of the
release

CCR Title 23, Sec 2652(c)

-An unauthorized release which does not escape from secondary
containment only requires a record on the operator's monitoring
reports provided:

A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary
containment
C. It was cleaned up within 8 hours of detection
D. All of the above - - D. All of the above

H&SC, Sec 25294

-The annual monitoring certification may be performed by:

A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the
monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - - D. A
person who meets the requirements of both a and b

,CCR Title 23, Sec 2715(i)

-The following is true of secondary containment testing,
EXCEPT:

a.) Must be tested every 24 months
b.) Must be tested every 36 months
c.) Results must be submitted to the local agency within 30 days
of testing
d.) Local agency must be notified 48 hours prior to testing - - a.)
Must be tested every 24 months

CCR Title 23, Sec 2637(a)

-Records of cathodic protection system maintenance must be
kept on file for ______________.

a.) 10 years
b.) 1.5 years
c.) 3 years
d.) 6.5 years - - d.) 6.5 years

CCR Title 23, Sec 2712(b)

-Impressed current cathodic protection systems shall be
inspected no less than every ___________ to ensure that they are
in proper working order:

a.) 60 days
b.) 90 days
c.) 30 days
d.) 120 days - - a.) 60 days

CCR Title 23, Sec 2635(a)(2)

-Monthly monitoring data must be kept on file for
_________________.

a.) 3 years
b.) 6.5 years

, c.) 5 years
d.) For the life of the UST system - - a.) 3 years

CCR Title 23, Sec 2712(b)

-By December 22, 1998, all automatic line leak detectors
installed on single-walled pressurized piping must be capable of:

a.) Restricting product flow
b.) Triggering an audible and visual alarm
c.) Shutting down the pumping system
d.) Shutting off the flow at the dispenser - - c.) Shutting down
the pumping system

CCR Title 23, Sec 2666(c)

-When an automatic tank gauge is utilized for single-walled tank
leak detection, it shall generate a post-test hard copy data report
of the following information, except:

a.) Liquid volume
b.) Fuel depth
c.) Outside air temperature
d.) Time and date of test - - c.) Outside air temperature

CCR Title 23, Sec 2643(b)(1)

-If a UST system is utilizing an overfill alarm, the alarm must be
triggered to alert the transfer operator when the tank is no more
than ___________ full

a.) 85%
b.) 95%
c.) 90%
d.) 80% - - c.) 90%

CCR Title 23, Sec 2635(b)(2)(A)

-A service technician has performed calibration and
maintenance on an ATG probe; this maintenance record must be
kept on file for ______________.

Geschreven voor

Vak

Documentinformatie

Geüpload op
17 mei 2023
Aantal pagina's
53
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$20.79
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseSallyD UNITED STATES
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
40
Lid sinds
3 jaar
Aantal volgers
35
Documenten
1104
Laatst verkocht
9 maanden geleden

4.9

7 beoordelingen

5
6
4
1
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen