complete test
Is this statement true or false? Fiberglass and flexible plastic piping do not need
to have cathodic protection.
False.
Cathodic protection
a technique used to control the corrosion of a metal surface by making it the cathode of
an electrochemical cell. A simple method of protection connects the metal to be
protected to a more easily corroded "sacrificial metal" to act as the anode.
Fill in the blank to make the statement correct. Owners and Operators must keep
the most recent ___ records of cathodic protection testing.
2
How long do owners and operators have to report a release to the implementing
agency?
24 Hours
Fill in the blank if the tank was installed on or before April 11, 2016 manual tank
gauging ALONE can be used on tanks containing ________ gallons and meeting
certain diameter requirements?
1000 gallons or less.
True or False?
Tanks from 1001 gallons to 2000 gallons and tanks from 551 and 1000 gallons
that do not meet the specified diameters can temporarily use manual tank
gauging when it is combined with tank tightness testing.
True
True or False?
Under UST regulation combining manual tank testing and tank tightness testing
can only be used for 10 years after the tank was installed and may not be used for
any tanks installed after April 11 2016.
True
True or False?
Manual tank gauging can be used to meet the release detection monitoring
requirements for any size of tank.
False
True or False?
Owners and operators may cancel a financial responsibility mechanism at any
time.
False
When can an owner or operator cancel a financial responsibility mechanism?
Only when they have obtained an alternative mechanism; the tank has been
, permanently closed or undergoes a change in service; or if corrective action is
required and completed.
Only when they have obtained an alternative mechanism; the tank has been
permanently closed or undergoes a change in service; or if corrective action is required
and completed.
True or False?
Owners and operators do not need to maintain financial responsibility once the
UST has been permanently closed.
True
True or false?
Septic tanks are regulated by the 40 CFR part 280.
False
Owners and operators who switch from E10 to E15 have 30 days AFTER
switching to notify the implementing agency.
False
They have 30 days BEFORE
Which of the following substances if stored in an
UST would cause the UST to be regulated under 40 CFR part 280? Choose all that
apply:
-Gasoline with 10% ethanol
-Propane
-Diesel
-Kerosene
gasoline with 10% ethanol, diesel, and kerosene.
How long do owners and operators keep records demonstrating compatibility
with gasoline containing 15% ethanol?
As long as the UST system stores 15% ethanol
True or false?
Only tanks need to be compatible with the regulated substances stored.
False
True or false? Under-dispenser containment used for piping interstitial
monitoring does not have to be tested for tightness once every three years.
False
True or false?
Double walled spill buckets where the space between the walls of the spill bucket
is no longer monitored at least every 30 days must be tested for liquid tightness
within -1 year after monitoring ceases-.
False. within 30 days
How often must overfill prevention equipment be inspected for operability?
Every 3 years