NICET Sample Exam Updated & Verified with 100% Correct Answers
Secondary power for remote supervising station systems shall be capable of normal operation for ___ hours and then operate the system in alarm for ___ minutes? Ans 24 / 5 A fire alarm system which serves contiguous or noncontiguous properties under one ownership is considered? Ans Proprietary system An initiating device which is destroyed as a result of operation is what type? Ans Nonrestorable The delay from the operation of an initiation device to the automatic activation of a fire safety function shall not exceed? Ans 10 seconds What documentation shall be delivered upon final acceptance of the system? Ans Owners manual and installation instructions, Record copy of site specific software, Record drawings What does an asterisk (*) designate in NFPA 72? Ans Explanatory information follows in Annex A What NFPA standard covers smoke detector requirements for HVAC units? Ans NFPA 90A Equipment constructed and installed in conformity with NFPA 72 shall be? Ans Listed Whom may serve as a AHJ? Ans Fire Marshal, Insurance Inspector, Building Owner When NFPA 72 uses the word "Shall", what does this indicate? Ans A mandatory requirement Fire power limited cabling used for runs between floors shall be of what type? Ans FPLR and FPLP For fire power limited cable what is the smallest multiconductor size and smallest single conductor size? Ans 26 AWG multiconductor, 18 AWG single conductor The disconnecting means for the fire alarm circuits shall be? Ans Identified in red, marked with "Fire Alarm Circuit" What is the maximum # of 18 AWG conductors which can be enclosed in a 4" x 4" x 1 1/4" square metal junction box? Ans 12 What is the maximum # of 14 AWG THHN conductors which can be installed in 1/2" EMT? Ans 12 Wall mounted visible appliances shall be installed such that the entire lens is ___ inches AFF and not more than ___ inches AFF. Ans 80" / 96" When installing detectors on peaked ceilings, a row of detectors shall be located? Ans Within 3 feet of the peak Public mode audible appliances shall have a sound level of ___db above the average ambient sound level. Ans 15db Manual fire alarm boxes shall be located within ___ feet of the doorway? Ans 5' Maintenance, testing and inspection records shall be maintained for how long? Ans Until the next test and 1 year thereafter
Written for
- Institution
- NICET Sample
- Course
- NICET Sample
Document information
- Uploaded on
- July 19, 2023
- Number of pages
- 5
- Written in
- 2022/2023
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
nicet sample exam updated amp verifiedo
Also available in package deal