Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NICET LVL 1 SG with 100% Correct Answers Updated & Verified

Beoordeling
-
Verkocht
-
Pagina's
5
Cijfer
A+
Geüpload op
19-07-2023
Geschreven in
2022/2023

If combination audible/ visible appliances are installed, the location of the installed appliance shall be determined by the requirements of the _____. Ans the visible appliance. The maximum number of 12- gauge THHN wires that can be installed in 1-inch EMT. Ans 26 Two resistors are connected in parallel. R1= 300 Ohms, R2=300 Ohms. What is their equivalent resistance? Ans 150 Ohms According to NFPA 72, visible notification appliances in non-sleeping areas must be mounted ____________ above the finished floor. Ans between 80 and 96 inches If fire alarm system impairment occurs, the owner must be notified in writing within _____. Ans 24 hours For visual notification, a 20x20 room with a 20 foot ceiling height requires at minimum a ______ ceiling mounted strobe. Ans 30 candella A 40x40 area with a 10 foot ceiling is best served by a _____ visible notification appliance, centered on one wall. Ans 60 candella Conductors returning to the fire alarm panel from the last field device suggests the circuit is wired as _____. Ans Class A Secondary power supply for a emergency voice/ alarm communications fire alarm system shall be capable of operating for a minimum of _____ in standby followed by ____ in alarm. Ans 24 hours/ 15 minutes Secondary power supplies shall automatically provide power within _____ of primary power failure. Ans 10 seconds Smoke detectors shall not be installed if the relative humidity is above _____. Ans 93 percent What does GFCI stand for? Ans Ground Fault Circuit Interrupter (GFCI) A fixed- temperature, non-restorable spot type heat detector shall be tested ____ from initial installation. Ans 15 years Heat detectors shall be selected to operate at least ____ above expected ambient temperature. Ans 20 degrees F Testing records shall be kept until the next test, as well as ____ additionally following that test. Ans 1 year _____ is responsible for storing and maintaining testing records. Ans The owner of the fire alarm system Household fire alarm system smoke detectors shall be tested ____ by a technician. Ans annually Inspection, testing, or maintenance of the fire alarm system shall be permitted to be done by the building or system owner or a person or organization other than the building or system owner if _____. Ans conducted under a written contract A manual pull station shall not be less than ____ and more than ____ from the finished floor. Ans 42/48 feet If the operation of a device, circuit, fire alarm control unit function, or special hazard system interface is simulated during a test, it must be _____. Ans documented on the testing form that the operation was simulated. What is the formula for determining total resistance of parallel resistors that have the same resistance value. Ans R= resistance / # of resistors For software based systems, a copy of the site specific software shall be provided to ____. Ans the system owner or owner's designated representative Manual pull stations shall be ___ in color. Ans red To determine the correct method of testing a fire alarm system component, refer to the table in NFPA 72, chapter ____. Ans 14.4.3.2 After a fire alarm system has been installed, the documentation should be stored ____. Ans in a document cabinet on the protected premises How should a non-restorable line type heat detector be tested? Ans Do not perform a heat test. Test functionality mechanically and electrically. Duct type smoke detectors shall be tested ___. Ans annually For installation of a heat detector with a listed spacing of 50 feet, what spacing should be used for a 20 foot ceiling that is smooth and flat. Ans 32 feet Smoke detectors that have provision for field adjustment of sensitivity shall have an adjustment range of ____ per foot obscuration. Ans not less than 0.6%

Meer zien Lees minder
Instelling
NICET LVL 1 SG
Vak
NICET LVL 1 SG









Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
NICET LVL 1 SG
Vak
NICET LVL 1 SG

Documentinformatie

Geüpload op
19 juli 2023
Aantal pagina's
5
Geschreven in
2022/2023
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Mawseron
4.0
(1)

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
Mawseron University of the People
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
6
Lid sinds
3 jaar
Aantal volgers
3
Documenten
198
Laatst verkocht
1 jaar geleden

latest updated documents, correct, verified & graded A study materials

4.0

1 beoordelingen

5
0
4
1
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen