Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Stryker Training Study Guide 2023 Questions and Answers with complete solution

Beoordeling
-
Verkocht
-
Pagina's
12
Cijfer
A+
Geüpload op
02-08-2023
Geschreven in
2023/2024

Stryker Training Study Guide 2023 Questions and Answers with complete solution What type of gas is used for laparoscopy and why? Insufflation = Co2 (Carbon Dioxide). Used because we naturally expel Co2 during the breathing process. -pediatric, bariatric, high flow (regular), and vessel harvest Name the 3 entry methods for delivering Co2. 1. Blind technique (Veress needle)- Small incision made, needle delivered by feel from Surgeon. Saline or water used through needle to ensure proper placement. 2. Open technique (Hasson cannula)- Surgeon cuts through layers of tissue and visualizes he has accessed abdominal cavity. Suture is used on both sides of incision to lock cannula into cavity. 3. Direct View technique- Operating cannula is used with cannulation down the center to insert laparoscope. Surgeon is viewing his entry. Measurements: Flow Pressure Flow - LPM = Liters per minute (How fast the gas is delivered) -default either 3 or 40) Pressure - mmHg = Millimeters of Mercury (How much gas will be delivered) -safety limit = 15, but bariatric abdominal wall is so thick and heavy that it may be set higher than 15 Does the insufflator turn off once the pre-set pressure is reached? No- insufflator does not turn off it just stops delivering gas. Once the actual pressure is lower then the pre-set pressure the device will deliver gas at the set flow rate. Sizes of Cannulas Standard sizes: Diameter: Measured in millimeters 5mm 10/11mm 12mm Length: Measured in millimeters 100mm 150mm

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Stryker Training Study Guide 2023 Questions and Answers
with complete solution
What type of gas is used for laparoscopy and why?
Insufflation = Co2 (Carbon Dioxide). Used because we naturally expel Co2 during the
breathing process.
-pediatric, bariatric, high flow (regular), and vessel harvest
Name the 3 entry methods for delivering Co2.
1. Blind technique (Veress needle)- Small incision made, needle delivered by feel from
Surgeon. Saline or water used through needle to ensure proper placement.

2. Open technique (Hasson cannula)- Surgeon cuts through layers of tissue and
visualizes he has accessed abdominal cavity. Suture is used on both sides of incision to
lock cannula into cavity.

3. Direct View technique- Operating cannula is used with cannulation down the center to
insert laparoscope. Surgeon is viewing his entry.
Measurements:

Flow

Pressure
Flow - LPM = Liters per minute
(How fast the gas is delivered)
-default either 3 or 40)

Pressure - mmHg = Millimeters of Mercury
(How much gas will be delivered)
-safety limit = 15, but bariatric abdominal wall is so thick and heavy that it may be set
higher than 15
Does the insufflator turn off once the pre-set pressure is reached?
No- insufflator does not turn off it just stops delivering gas. Once the actual pressure is
lower then the pre-set pressure the device will deliver gas at the set flow rate.
Sizes of Cannulas
Standard sizes:

Diameter: Measured in millimeters
5mm
10/11mm
12mm

Length: Measured in millimeters

100mm
150mm

, Define:

Obturator

Trocar
Obturator = Dull insertion rod for cannula, sometimes called pencil tip.

Trocar = Sharp insertion rod for cannula.
What must every insufflation tubing have on it?
A Filter
What does the tank yoke do?
Attaches the insufflator line to the gas tank. Special yokes are designed for Co2 tanks
and cannot be interchanged with other gases.
Three warning signs for the insufflator.
1. Occulsion = Something is blocking the flow of the gas being delivered to the
abdomen. Check stopcock on cannula.

2. Overpressure = When the actual gets over the pre-set pressure. Different insufflators
had different limits.

3. Leakage = When the insufflator continuously runs for a pre-determined amount of
time.
Why are insufflators called high-flow?
They can deliver a high amount of gas within one minute. Most insufflators that are
high-flow have a flow rate of 30 to 45 lpm.
Each gas tank can hold...
600L of CO2
What 4 catagories should be used to breakdown laparoscopic instrumentation?

Inserts

Handles / Shafts
Inserts:
1. Dissectors
2. Graspers
3. Scissors
4. Single Action / Double Action

Handles / Shafts:
1. Locking , Non-locking
2. Length - 29cm , 33cm , 45cm
3. Diameter - 3mm , 5mm , 10mm
4. Coated insulation or PEEK shafts
graspers
blunt, round tip
-used to grab and hold onto

Geschreven voor

Vak

Documentinformatie

Geüpload op
2 augustus 2023
Aantal pagina's
12
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LECTMAGGY Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
146
Lid sinds
3 jaar
Aantal volgers
121
Documenten
6311
Laatst verkocht
1 week geleden
LECTMAGGY

Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.3

28 beoordelingen

5
8
4
3
3
11
2
0
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen