Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

NATE ICE Flashcards. Top Exam Questions & Answers. 100% Accurate. VERIFIED.

Beoordeling
-
Verkocht
-
Pagina's
12
Cijfer
A+
Geüpload op
10-08-2023
Geschreven in
2023/2024

NATE ICE Flashcards. Top Exam Questions & Answers. 100% Accurate. VERIFIED. After a vacuum pump has been used, a continuous pressure rise in the system most likely indicates - -existence of a leak after a vacuum has been pulled to 500 microns, a pressure rise in the system, followed by a leveling-off at 1500 microns, most likely indicates the - -presence of a moisture on initial start up of an air conditioning system, the temperature drop measured across the evaporator coil exceeds manufacturer's specifications. this condition most likely indicates - -lack of refrigerant charge the technician is on a spring maintenance check of an air conditioning system. they find the following - head pressure is higher than normal, suction pressure higher than normal, superheat 0 degrees, condenser is clean, outdoor fan operation is normal, subcooling is 25 degrees. which of the following is most likely the problem? - -non-condensibles in the system in a compressor, the internal overload senses the winding temperature and - -amperage in the compressor circuit the function of an external equalizer line for a thermostatic expansion valve is to - -reference the pressure at the evaporator outlet in a fixed orifice air conditioning system, the presence of non-condensables in the system will cause - - -high head and high suction pressures which one of the following could possibly cause a noisy reciprocating compressor? - -broken internal springs two places where superheating occurs in a system are the - -evaporating coil and the compressor if the fan switch on a thermostat sub-base is set to ON and the blower motor is cycling on and off, the most probable cause is - - -motor overload when you are checking for windings of a single-phase compressor with an ohmmeter, the highest ohm reading would be - - -start to run a compressor does not run, although the condenser fan is operating. reading the compressor windings, the measured resistance between r to a is 5 ohms, r to c is open and s to c is open. the problem is due to - - -internal overload being open a compressor with tight bearings will cause the amperage to draw to - -rise above normal which of the following can be caused by insufficient air flow? - -increased compressor failure a correct statement about a hard start kit is that it - -increases starting torque across an r-22 suction line drier, how much pressure drop indicates changing the drier? - -3 psig which one of the following can be caused by a restricted air filter? - -high superheat which of the following would most likely occur if a crankcase heater fails? - -the refrigerant may not be driven out of the oil a correct statement concerning a relay is that it - -consists of one or more contacts actuated by a solenoid coil the control voltage in an air conditioning system comes directly from - - -the secondary of a step down transformer in a residence, a slight positive indoor air pressure - - -minimizes infiltration which of the following is an important factor when selecting a location for placement of a condensing unit? - -should avoid standing groundwater and roof water runoff which of the following installation steps is necessary to maximize the efficiency of a condensing unit? - -minimum clearances must be maintained around the condensing unit which of the following will contribute to customer comfort and cooling system efficiency? - -select equipment based on load circulation cross breaking sheet metal duct will - - -stiffen the duct and reduce noise the nominal indoor airflow through an air conditioner evaporator coil should be approximately - - -400 cfm/ton the purpose of the tabs at the top and bottom of the drive cleat is to - - -prevent movement of the drive cleat the sheet metal duct system which has main ducts of equal size is the - - -extended plenum system which of the following is the major benefit of using long radius fittings in a duct system? - -less pressure drop with a psc blower motor, what happens to static pressure as supply dampers are closed in a duct systems? - -increases

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

NATE ICE Flashcards. Top Exam
Questions & Answers. 100% Accurate.
VERIFIED.

After a vacuum pump has been used, a continuous pressure rise in the system most likely indicates -
✔✔-existence of a leak



after a vacuum has been pulled to 500 microns, a pressure rise in the system, followed by a leveling-off
at 1500 microns, most likely indicates the - ✔✔-presence of a moisture



on initial start up of an air conditioning system, the temperature drop measured across the evaporator
coil exceeds manufacturer's specifications. this condition most likely indicates - ✔✔-lack of refrigerant
charge



the technician is on a spring maintenance check of an air conditioning system. they find the following -
head pressure is higher than normal, suction pressure higher than normal, superheat 0 degrees,
condenser is clean, outdoor fan operation is normal, subcooling is 25 degrees. which of the following is
most likely the problem? - ✔✔-non-condensibles in the system



in a compressor, the internal overload senses the winding temperature and - ✔✔-amperage in the
compressor circuit



the function of an external equalizer line for a thermostatic expansion valve is to - ✔✔-reference the
pressure at the evaporator outlet



in a fixed orifice air conditioning system, the presence of non-condensables in the system will cause - -
✔✔-high head and high suction pressures



which one of the following could possibly cause a noisy reciprocating compressor? - ✔✔-broken internal
springs

, two places where superheating occurs in a system are the - ✔✔-evaporating coil and the compressor



if the fan switch on a thermostat sub-base is set to ON and the blower motor is cycling on and off, the
most probable cause is - - ✔✔-motor overload



when you are checking for windings of a single-phase compressor with an ohmmeter, the highest ohm
reading would be - - ✔✔-start to run



a compressor does not run, although the condenser fan is operating. reading the compressor windings,
the measured resistance between r to a is 5 ohms, r to c is open and s to c is open. the problem is due to
- - ✔✔-internal overload being open



a compressor with tight bearings will cause the amperage to draw to - ✔✔-rise above normal



which of the following can be caused by insufficient air flow? - ✔✔-increased compressor failure



a correct statement about a hard start kit is that it - ✔✔-increases starting torque



across an r-22 suction line drier, how much pressure drop indicates changing the drier? - ✔✔-3 psig



which one of the following can be caused by a restricted air filter? - ✔✔-high superheat



which of the following would most likely occur if a crankcase heater fails? - ✔✔-the refrigerant may not
be driven out of the oil



a correct statement concerning a relay is that it - ✔✔-consists of one or more contacts actuated by a
solenoid coil

Geschreven voor

Vak

Documentinformatie

Geüpload op
10 augustus 2023
Aantal pagina's
12
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
PassPoint02 Chamberlain School Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
176
Lid sinds
4 jaar
Aantal volgers
105
Documenten
4576
Laatst verkocht
1 maand geleden

4.1

39 beoordelingen

5
22
4
6
3
5
2
4
1
2

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen