Consisting Of 100 Questions With Verified Answers From
Experts
SNT-TC-1A is not intended to be used as a strict
specification.
Which of the following statements is true concerning the usage of SNT-TC-1A?
Written and stated in general terms
The SNT-TC-1A Interpretation Panel will respond to inquiries about SNT-TC-1A. The
inquiry must be:
May engage an outside service but is, nevertheless,
responsible for the certification of the company's NDT
personnel
With regard to the training of NDT personnel, the employer:
To establish their own written practice that must be used
as a strict specification.
SNT-TC-1A is intended as a guideline for employers:
The employer should review the detailed
recommendations and modify them as necessary to meet
its particular needs.
The following is a statement in SNT-TC-1A "It is recognized that these guidelines may
not be appropriate for certain employers; circumstances and / or applications." What
should be done if the guidelines are not appropriate?
The individual's employer.
Who should be responsible to assess whether or not an individual should be qualified
and certified who does not perform NDT, but monitors and evaluates NDT?
Holographic testing
To which of the following NDT methods is SNT-TC-1A currently not applicable
With flexibility and reason
ASNT intended that the recommendations of SNT-TC-1A be applied
The employer.
Of the following, which is most appropriate to determine the needs to qualify and certify
personnel whose only NDT function is to operate digital thickness equipment.
Written testimony of qualification.
Certification is
, It has been specified by the customer.
Use of SNT-TC-1A is mandatory when:
Level I, II, III.
The basic levels of qualification recommended by SNT-TC-1A are:
Weather any NDT personnel should be qualified and
certified depends solely upon the needs of the employer
and the requirements of the employer's customers or
clientele.
Should personnel that operate ultrasonic digital thickness measurement equipment to
qualified and certified
The Trainee may not conduct nondestructive test
independently and may not report test results
According to the recommendations of SNT-TC-1A which of the following is true
concerning a Trainee's activities?
Must train and examine the Level I and II personnel in his
or her organization.
According to SNT-TC-1A, which of the following is not true for a Level III?
Specific calibrations, Specific nondestructive test,
specific evaluations, and write reports of test results.
According to written instructions, an NDT Level I may be qualified to perform:
Yes, the intent in SNT-TC-1A is that the Level I may
perform the above functions provided that they are in
accordance with written instruction of a Level III or
designee.
May a Level I independently perform, evaluate and sign for results of nondestructive
test with supervision and guidance from a Level II or III?
The qualifications for Level III equal and exceed those of
Level II.
Which of the following statements is true concerning the definitions of Trainee, Level I, II
and III in SNT-TC-1A?
Establish techniques
Which of the following is not within the scope of activities of a Level II individual, as
recommended in SNT-TC-1A?
My conduct on the job training and guidance of Level I
personnel.
A recommended in SNT-TC-1A, a Level II: