FDNYC G60 Study Guide Questions and Answers 2023.
FDNYC G60 Study Guide Questions and Answers 2023. 1. G-60: Use of oxygen and flammable gasses, or LPG or CNG for any hot work 2. COF exception: Torch operations for jewelry 3. FDNY permit: Storing using or handling oxygen and flammable gas in excess of 400scf (LPG, CNG or scetylene) oxidizing gass in excess of 504scf 4. Portable LPG must not be stored when the capacity of the container is greater than?: 16.4 oz 5. Portable CNG containers must not be stored then the capacity is greater than?: 8.7 SCF 6. Single standard portable LPG containers must not exceed?: 100LBs in weight 7. Single CNG containers must not exceed?: 381 SCF 8. LPG 400 SCF is approximately: 47 lbs 2 / 28 9. Types of FDNY permits: Site specific permits City wide permits Transportation permits 10. Site specific permit can be?: Can be permenant or temperary 11. Permanent permits are valid for how long?: 12 months only. Permits and renewals require inspection and will expire adter twelve months. 12. Temporary permits may be valid from?: One day to 12 months depending on the construction or operations needed. 13. City wise permit duration?: 30 days Hazards out end of day 14. Quantity of hazardous material being stored(maximum)?: 5 gals gasoline 250 gals of flammable 300 gals combustible liquid 15. Transportation permit: FDNY approved inspected displayed on vehicle 16. Hot work authorization.: Required for any project with hot work operation but not issued by the FDNY 3 / 28 17. Responsible person: Must be available for inspection by any representative of fire department during and 48 hours after the work is complete. 18. Fire guard: Cof holder who is trained in and responsible for maintaijjng a fire watch. 19. Fire watch: Survailance of an area Detect signs of early fire Raise alarms Notify department 20. Pre hot work check must be conducted by the responsible person before hot work is authorized at least?: Once per day 21. Pre hot work check daily and must very the following: Equipment working in order Hot work is clear of combistibles and flammable solids Combustible and non combustible are protected Fire watch personel are assigned Fire extinguisher available 22. Fire watch: A fire watch must be maintained during any hot work operation.
Geschreven voor
- Instelling
- FDNYC G60
- Vak
- FDNYC G60
Documentinformatie
- Geüpload op
- 19 augustus 2023
- Aantal pagina's
- 69
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
fdnyc g60 study guide
-
fdnyc g60 study guide questions and answers 2023
-
fdnyc g60 study guide questions and answers
-
fdnyc g60 study guide 2023
-
fdnyc g60 questions and answers 2023
Ook beschikbaar in voordeelbundel