NCCER ELECTRICAL LEVEL 3 Module 6 'Distribution Equipment' 2023 Questions and Answers Which of the following is true with regard to switchboards Switchboards are used to subdivide large blocks of power When installing wiring within switchgear, use self adhesive cable ties every ___. 12" (300mm) The maximum voltage that a piece of equipment can withstand is known as its ____. Basic impulse insulation level (BIL) Bolted pressure switches are often used in place of ___. Circuit breakers A transformer's temperature rise rating refers to ___. The maximum elevation above ambient temperature that the transformer can withstand without insulation damage A service has a three-phase supply with 14 single-pole circuits and 4 three-pole circuits. The minimum number of poles required is ___. 30 Per NEC Section 408.3(E)(1), AC phasing in switchboards must be labeled ___. A,B,C from front to back, top to bottom, or left to right when read facing the front of the switchboard On a typical electrical diagram, the standard abbreviation for a phase meter is __. PH The typical insulation resistance of equipment rated at 480V is ___. 100 megohms A typical overpotential test voltage for a used piece of equipment with a nominal voltage class of 600V is ___. 2,000 VDC A ground fault relay should be mounted in an enclosure ___. In a vertical position with the terminal block at the lower end In Industrial applications, medium voltage may refer to systems rated over ___. 1,000V up to 35,000V The term Interrupting rating refers to the ___. maximum current a device will safely interrupt at rated voltage Which of the following is NOT a general classification of circuit breakers? Fuse circuit breaker A 4,000A switchboard requires a minimum distance from the phase bus to the closest steel member of ____. 6" (150mm) When an unintended path is established between an ungrounded conductor and ground, it is called a(n)____. ground fault A transformer rated at more than 500kVA is considered a(n) ___. power transformer The term capacity on a transformer nameplate refers to ____. its ability to transfer energy

Show more Read less
Institution
Course

Content preview

NCCER ELECTRICAL LEVEL 3 Module 6 'Distribution
Equipment' 2023 Questions and Answers
Which of the following is true with regard to switchboards
Switchboards are used to subdivide large blocks of power
When installing wiring within switchgear, use self adhesive cable ties every ___.
12" (300mm)
The maximum voltage that a piece of equipment can withstand is known as its
____.
Basic impulse insulation level (BIL)
Bolted pressure switches are often used in place of ___.
Circuit breakers
A transformer's temperature rise rating refers to ___.
The maximum elevation above ambient temperature that the transformer can withstand
without insulation damage
A service has a three-phase supply with 14 single-pole circuits and 4 three-pole
circuits. The minimum number of poles required is ___.
30
Per NEC Section 408.3(E)(1), AC phasing in switchboards must be labeled ___.
A,B,C from front to back, top to bottom, or left to right when read facing the front of the
switchboard
On a typical electrical diagram, the standard abbreviation for a phase meter is __.
PH
The typical insulation resistance of equipment rated at 480V is ___.
100 megohms
A typical overpotential test voltage for a used piece of equipment with a nominal
voltage class of 600V is ___.
2,000 VDC
A ground fault relay should be mounted in an enclosure ___.
In a vertical position with the terminal block at the lower end
In Industrial applications, medium voltage may refer to systems rated over ___.
1,000V up to 35,000V
The term Interrupting rating refers to the ___.
maximum current a device will safely interrupt at rated voltage
Which of the following is NOT a general classification of circuit breakers?
Fuse circuit breaker
A 4,000A switchboard requires a minimum distance from the phase bus to the
closest steel member of ____.
6" (150mm)
When an unintended path is established between an ungrounded conductor and
ground, it is called a(n)____.
ground fault
A transformer rated at more than 500kVA is considered a(n) ___.
power transformer
The term capacity on a transformer nameplate refers to ____.

Written for

Course

Document information

Uploaded on
August 30, 2023
Number of pages
4
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$10.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF


Also available in package deal

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
LECTMAGGY Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
146
Member since
3 year
Number of followers
121
Documents
6330
Last sold
1 month ago
LECTMAGGY

Here, you will find everything you need in NURSING EXAMS AND TESTBANKS.Contact us, to fetch it for you in minutes if we do not have it in this shop.BUY WITHOUT DOUBT!!!!Always leave a review after purchasing any document so as to make sure our customers are 100% satisfied.

3.3

28 reviews

5
8
4
3
3
11
2
0
1
6

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions