Elevator mechanics review Car running up keep stopping why? - Answer Contact is not deenergizing in push button Third-floor bulbs burn out why? - Answer Shorted resistor Car will not travel to second floor without a third-floor me a call and will not go down from three without a second-floor hall, what's the problem? - Answer 2Fl 4/6 Why won't motor start? - Answer MOL1 95/96 Car doors closed and won't run what do you check? - Answer Check for voltage at four and five Bad Transistor Top barricade can be replaced with? - Answer 1/4" Cable There is voltage at the switch but none at point a what's wrong? - Answer Either R1 or R2 open The door close limit switch is not working do you have power from 35 to term eight. No power from 1 to 52 why? - Answer Door limit switch malfunction Car running normally but the buzzer will not shut off why? - Answer EHP 2/3 shorted Relay STR has voltage. TRU has voltage, RU has no voltage, why? - Answer TRU 9/8 Second floor PI illuminates then quickly extinguishes why? - Answer X1 4/6 On a machine, what is drilled out first? - Answer Secondary sheave Dumb waiter takes off before loading why? - Answer Non interference Car levels in 3 inches high in down direction why? - Answer Counterweight In bi-parting doors what gap is allowed before gate switch is open? - Answer 3/4" Pressure switch is wired in what direction - Answer Down directional What is the tripping speed of counterweight governor? - Answer No more than 10% higher There is excessive sparking on generator why? - Answer High Micha How does interpoles affect the Armature? - Answer Reaction What is the maximum door closing force? - Answer 30 lbs and 7 lbs kinetic What do you do before replacing a relay on a controller? - Answer LOTO, Test, and Verify When are spring buffers used? - Answer Less than 200fpm What are SCR's good for? - Answer They are quieter and make less vibration then motor generator set You have a 200 ohm resistor at 200 Watts what do you replace it with? - Answer 75 ohm 200 watt adjustable resistor Pump overload keeps tripping. How do you measure amperage? - Answer Clamp on meter separately each wire Customer complains about a third floor PI bulb burned out, why? - Answer Shorted resistor There are three elevators, 12 floors, customer does not want PI's on second, seventh, and eighth floor. How many total PI 's? - Answer 27 PI's 10k ohm resistor with 500mF. How long will it take to charge capacitor? - Answer 5 sec What do you do before running a Hydro after car is built? - Answer Check piston for debris and make sure head is tight How to tell which side is right or left hand doors? - Answer Inside looking out If you get a complaint that all floors make noise, what should you check? - Answer Car doors What is the issue if you add power to a generator but the motor doesn't gain any more speed? - Answer Generator is saturated
Geschreven voor
- Instelling
- Elevator mechanics
- Vak
- Elevator mechanics
Documentinformatie
- Geüpload op
- 7 november 2023
- Aantal pagina's
- 10
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
elevator mechanics review
-
elevator mechanics exam
-
elevator mechanics review with 100 correct answer
-
car running up keep stopping why answer contact
-
third floor bulbs burn out why answer shorted r