True or False: The FireFighter may be installed next to a stand-alone battery-powered smoke detector. - ANSWER False True or False: When performing a full system test, you may bypass any open doors or windows. - ANSWER False When programming an SKEY1, you must Always...? - ANSWER Enable emergency key True or False: When running power to the TAKE-345, polarity does not apply. - ANSWER False When programming the emergency key for an SKEY1, which zone/sensor types are recommended to use? - ANSWER Auxiliary and audible alarm True or False: When installing an SMKT3, you must use the included screws and anchors - ANSWER True True or False: When installing the Fire Fighter, it is required to test the customer's existing smoke detectors. - ANSWER T When installing a DW21, where is the approved location for the sensor? - ANSWER Btw 6 & 2 in from the floor When installing a DW11 on a vinyl or metal frame, what should you primarily use to mount the sensor? - ANSWER Double sided tape Select all that apply: Which of the following materials can you use to group multiple ground terminals in a Takeover module? - ANSWER Wire caps or B connectors/Beans What sensor are you not allowed to program using a translator? - ANSWER Smoke detector True or False: When installing the TAKE-345 you must always test the new 12v Battery before using it. - ANSWER True What is the output voltage of the transformer used to power the Smart Hub? - ANSWER 12 VDC What is the minimum distance for placement of a CO3 from the corners on a wall? - ANSWER 12 in True or False: The SMKT3 has only 2 functions: smoke and heat detection. - ANSWER False How would you program a CO3 if mounted on a hallway wall? - ANSWER Loop 1, zone type 14 True or False: When installing a translator, you must program all of the existing sensors as new equipment on the panel. - ANSWER false When programming a DW11 that has been installed on a window, which zone/sensor type should you use? - ANSWER 3 True or False: The DW21 sensor should always be installed in the door frame - ANSWER True What equipment is used on all metal door frames - ANSWER DW11 Which zone/sensor types are used when programming an SMKT3? - ANSWER Type 9 smoke detection, type 8 freeze detection, type 9 heat detection What is the correct height at which to install the PIR2? - ANSWER 7.5 ft When programming a DW21, which loop number is used? - ANSWER 1 True o
Written for
- Institution
- Vivint
- Course
- Vivint
Document information
- Uploaded on
- January 6, 2024
- Number of pages
- 4
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
vivint practice quiz questions solutions
-
vivint practice quiz questions solutions stuvia
-
true or false the firefighter may be installed ne
-
true or false when performing a full system test
Also available in package deal