Vivint Smart Home Pro Final Exam Already Passed
12-24v - ANSWER What is the input voltage range of the Doorbell Cam? 16.5 VAC - ANSWER What is the output voltage of the transformer used to power the SkyControl panel? true - ANSWER True or False: When programming a sensor into the sky panel you can type in the serial number or "learn" it in by triggering the device 2 - ANSWER When programming a DW21, which loop number is used? 1 2 3 beans and wire caps - ANSWER Which of the following materials can you use to group multiple ground terminals in a takeover module: Solder String Wire Caps Duct Tape Beans True - ANSWER T or F: When installing the firefighter, it is required to test the customer's existing smoke detectors 3/4" - ANSWER When installing a DW21, what size bit should you use to drill the hole for the sensor? 1/2" 3/8" 3/4" 1" True - ANSWER T or F: When installing the TAKE-345, you must ensure that the transformer is supplying power to the power supply before the battery. True - ANSWER T or F: You are required to test signals from all secondary keypads and key fobs even though they are not detection devices False - ANSWER T or F: When running power to the TAKE-345 polarity does not apply - ANSWER What is the correct height at which to install the PIR2? 7 ft At least 5 ft At least 7 ft At 7.5 ft How would you program a CO3 if mounted on a hallway wall? Loop 1 Zone 8 Loop 1 Zone 14 Loop 3 Zone 4 Loop 1 Zone 4 - ANSWER When installing a DW21 into a metal door frame, with a wooden door, what should you be sure to use? Metal Drill bit A DW11 should be used on all metal door frames 3/4" insulated magnet Eye goggles - ANSWER True - ANSWER T or F: Panic Pendants are programmed as an audible alarm T or F: The Firefighter may be installed next to a stand-alone battery-powered smoke detector - ANSWER Which of the following zone/sensor types are correct when programming an SMKT3? Type 9 - Freeze Detect Type 7 - Freeze Detect Type 9 - Heat detect Type 6 - heat detect type 1 - heat detect type 8 - freeze detect type 5 - smoke detect type 7 - smoke detect type 9 - smoke detect - ANSWER When installing a DW21 where is the approved location for the sensor? Anywhere in the door between 6"(15 cm) and 2' (61 cm) from floor Below 6" from the floor Top of the door - ANSWER T or F: When performing a full system test, you may bypass any open doors or windows - ANSWER T or F: When installing a translator, you must program all of the existing sensors as new equipment on the panel - ANSWER
Written for
- Institution
- Vivint
- Course
- Vivint
Document information
- Uploaded on
- January 6, 2024
- Number of pages
- 6
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
vivint smart home pro final exam already passed
-
vivint smart home pro final exam stuvia
-
12 24v answer what is the input voltage range o
-
true answer true or false when programming a s
Also available in package deal