Army Electrical Explosives
Safety (Ammo-28) Exam with
complete solution 2023-2024




Which two publications provide detailed information on lightning protection systems? - AnswersDA
PAM 385-64

NFPA 780



Which statements about lightning protection are true?Select all that apply. - AnswersLightning can
detonate munitions and explosives.



Lightning seeks the path of least resistance to ground.



Lightning cannot be stopped or prevented.



Which statement is true about a mast LPS? - AnswersEach mast must have two paths to ground.



A 30-foot tall building is protected by a catenary system. How far from the building should the masts
be placed? - Answersat least 6 feet



Which LPS uses air terminals and conductors mounted directly to the structure? - AnswersIntegral



Why does the wooden mast have an air terminal on top and two down conductors running its entire
length? - AnswersThe wooden mast is not electrically conductive

, Which of the following is NOT a requirement for air terminals? - AnswersAir Terminals must be at
least 6 feet tall.



During the inspection, John's team logged a discrepancy for this air terminal. Why? - AnswersThe air
terminal is not attached to a conductor.



How many down conductors are required for a building with a perimeter length of 325 feet? -
Answers4



While conducting an LPS inspection, you see mast down conductors routed as shown in the image
below. Do you write it up as a discrepancy? Why or why not? - AnswersYes, because mast down
conductors should be 180 degrees apart.



A steel beam, connected to the main LPS at its upper and lower extremities, is used as a down
conductor. At what intervals should it be connected to the grounding system? - Answers60 feet or
less



Which statement about grounding systems is true? - AnswersThe resistance should be 25 ohms or
less.



Which of the following statements regarding bonding are true? Select all that apply. -
AnswersBonding reduces the threat of sideflash by providing a low impedance path to ground.



Bonding is a way of connecting LPS conductors to grounded metal objects.



When should a grounded metal object be considered for bonding? - AnswersWhen it's within 6 feet
of a conductor



Which bonding method is the most permanent and secure? - AnswersExothermic weld



Which factors are used to calculate bonding distance?Select all that apply. - AnswersHeight of
proposed bond



Flashover medium

Written for

Course

Document information

Uploaded on
January 11, 2024
Number of pages
7
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.19
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
annahalexis17

Get to know the seller

Seller avatar
annahalexis17 Teachme2-tutor
Follow You need to be logged in order to follow users or courses
Sold
1
Member since
2 year
Number of followers
0
Documents
337
Last sold
1 year ago

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions