Since 1992, the United States Department of Energy has required that
all furnaces sold and installed from that date on must have an AFUE of
no less than:
A: 70%
B: 75%
C: 78%
D: 80% - -C: 78%
-Many pre-1992 furnaces have efficiencies around _______.
A: 10%
B: 40%
C: 60%
D: 80% - -C: 60%
-Today, furnaces with AFUE ratings greater than _____ are available.
A: 85%
B: 90%
C: 100%
D: 110% - -B: 90%
-A thermocouple is used with:
A: Intermittent pilot systems
B: Direct spark ignition systems
C: Glow coil ignition systems
D: Standing pilot ignition systems - -D: Standing pilot ignition systems
, -The purpose of the gas pressure regulator is to:
A: Keep the color of the flame constant
B: Keep the high limit switch from tripping
C: Maintain a constant gas pressure at the burner
D: Allow the gas valve to operate smoothly and accurately - -C:
Maintain a constant gas pressure at the burner
-The instrument used to measure outlet gas pressure is the:
A: Velometer
B: Anemometer
C: Monometer
D: Draft gauge - -C: Monometer
-The regulator on a natural gas furnace should be adjusted to supply
_____ inches of pressure at the burners.
A: 11"
B: 10"
C: 3.5"
D: 2" - -C: 3.5"
-Burning one cubic foot of natural gas releases approximately _____ btu.
A: 800
B: 1,050
C: 12,000
D: 15,000 - -B: 1,050
-Under ideal conditions natural gas has an ignition temperature of
_______ degrees F and a burning temperature of ________ degrees F.
A: 800 degrees, 1000 degrees
B: 1,100 degrees, 3,500 degrees
Exam2024/Updated/50
Questions and Answers/A+
Rated
Since 1992, the United States Department of Energy has required that
all furnaces sold and installed from that date on must have an AFUE of
no less than:
A: 70%
B: 75%
C: 78%
D: 80% - -C: 78%
-Many pre-1992 furnaces have efficiencies around _______.
A: 10%
B: 40%
C: 60%
D: 80% - -C: 60%
-Today, furnaces with AFUE ratings greater than _____ are available.
A: 85%
B: 90%
C: 100%
D: 110% - -B: 90%
-A thermocouple is used with:
A: Intermittent pilot systems
B: Direct spark ignition systems
C: Glow coil ignition systems
D: Standing pilot ignition systems - -D: Standing pilot ignition systems
, -The purpose of the gas pressure regulator is to:
A: Keep the color of the flame constant
B: Keep the high limit switch from tripping
C: Maintain a constant gas pressure at the burner
D: Allow the gas valve to operate smoothly and accurately - -C:
Maintain a constant gas pressure at the burner
-The instrument used to measure outlet gas pressure is the:
A: Velometer
B: Anemometer
C: Monometer
D: Draft gauge - -C: Monometer
-The regulator on a natural gas furnace should be adjusted to supply
_____ inches of pressure at the burners.
A: 11"
B: 10"
C: 3.5"
D: 2" - -C: 3.5"
-Burning one cubic foot of natural gas releases approximately _____ btu.
A: 800
B: 1,050
C: 12,000
D: 15,000 - -B: 1,050
-Under ideal conditions natural gas has an ignition temperature of
_______ degrees F and a burning temperature of ________ degrees F.
A: 800 degrees, 1000 degrees
B: 1,100 degrees, 3,500 degrees