Nevada MPJE Set 3 Exam/14
Questions With Solved Correct
Answers/Verified
How many days should a warehouse notify the board of a change in
ownership - -5
-How long should records be kept by a warehouse - -2 years
-If record of a ware house are not maintainbon premises how long do
you have to reproduce it. - -2 working days
-BUD for non aqueous liquid and solid formulations - -6 months
-BUD -aqueous or non sterile water - -14 days
-sterile compounding room requirements - -1. ISO Class 5 environment (
laminar flow hood)
2. Buffer area must be ISO Class 7 environment
3. Ante-area must be ISO Class 8 environment
4. Maintains a Constant temperature and humidity
-Laminar flow hood ( ISO Class 5) cleaning - -1. Beginning of each work
shift
2. Before compounding of each batch
3. Every 30 mins after compounding sterile products
4. After a know spill
5. Whenever it's contaminated
-IV room floors must be cleaned - -At least Once a day
-IV room ceiling, storage, shelving and walls must be cleaned how often
- -Once a month
-single dose vial bud after breach - -1 hour if breach occurred in ISO
Class 5 but stored in ISO class 8 or worse
6 hours if breach occurred in ISO Class 5 and stored in ISO Class 7
24 hours of breached in ISO class 5 and Stored in ISO class 5
-multidose vial bud after breach - -28 days stored as required by
manufacturer
If deal is completely removed it must be destroyed
-Low Risk Compounding storage - -48 hours room temp
14 days refrigerator
45 days frozen
Questions With Solved Correct
Answers/Verified
How many days should a warehouse notify the board of a change in
ownership - -5
-How long should records be kept by a warehouse - -2 years
-If record of a ware house are not maintainbon premises how long do
you have to reproduce it. - -2 working days
-BUD for non aqueous liquid and solid formulations - -6 months
-BUD -aqueous or non sterile water - -14 days
-sterile compounding room requirements - -1. ISO Class 5 environment (
laminar flow hood)
2. Buffer area must be ISO Class 7 environment
3. Ante-area must be ISO Class 8 environment
4. Maintains a Constant temperature and humidity
-Laminar flow hood ( ISO Class 5) cleaning - -1. Beginning of each work
shift
2. Before compounding of each batch
3. Every 30 mins after compounding sterile products
4. After a know spill
5. Whenever it's contaminated
-IV room floors must be cleaned - -At least Once a day
-IV room ceiling, storage, shelving and walls must be cleaned how often
- -Once a month
-single dose vial bud after breach - -1 hour if breach occurred in ISO
Class 5 but stored in ISO class 8 or worse
6 hours if breach occurred in ISO Class 5 and stored in ISO Class 7
24 hours of breached in ISO class 5 and Stored in ISO class 5
-multidose vial bud after breach - -28 days stored as required by
manufacturer
If deal is completely removed it must be destroyed
-Low Risk Compounding storage - -48 hours room temp
14 days refrigerator
45 days frozen