Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Florida Home Inspector Exam Questions With Correct And Complete Solutions

Beoordeling
-
Verkocht
-
Pagina's
115
Cijfer
A+
Geüpload op
18-01-2024
Geschreven in
2023/2024

Florida Home Inspector Exam Questions With Correct And Complete Solutions Service entrace conductors run from the service drop to the service box or service panel. True or False? True The service size is determined by the amperage and the voltage ratings of the service. True Is the service drop overhead or underground? Overhead Are service laterals overhead or underground? Underground The drip loop is typically part of the service drop. True or False? False The wire size for the service drop must be the same as the wire size for the service entrance conductors. True or False? False How many wires would you typically find in a 240-volt service drop? 3 What would 4 wires mean? 3-phase electricity What would 2 wires usually mean? 120 volt service List 7 common problems with service drops. 1. Overhead wires too low. 2. Damaged or frayed wires. 3. Trees or vines interfering with wires. 4. Wires too close to doors or windows. 5. Wires not well-secured to the house. 6. Poor connection between service drop and service entrance. 7. Inadequate clearance from roofs. List clearances above ground, swimming pools, and roofs. above roadway--18 ft. above driveway--12 ft. above flat roof--8 to 10 ft. above sloped roof--18 inches away from water in swimming pool--22.5 ft 3 ft. above sloped roof with pitch 4 in 12 above walkway--10 ft. The service entrance conductors run from the _________ to the ___________. service drop to service box All service entrance conductors must be in conduit. True or False? False All service entrance conductors must be attached above roof level. True or False? False The drip loop should be as close to the roof as possible. True or False? False List 10 common problems with service entrance conductors. 1. No drip loop 2. No mast head 3. Mast head not weather tight. 4. Mast or conduit bent. 5. Mast or conduit rusted. 6. Mast rotted (if wood). 7. Mast conduit or cable not well secured. 8. Mast conduit or cable not weather tight. 9. Conduit or cable not well sealed at house/wall penetration. 10. Cable frayed, damaged, or covered by siding. List 4 common areas of water penetration into service entrances. 1. conduit joints 2. mast head 3. roof flashing 4. meter base 5. house entry List 2 functions of the drip loop. 1. Prevents water entry into the conduit or service entrance conductors. 2. Shows that the service drop wires are not straining the splices. Roughly 999 out of 1000 houses have _________ volts available. 240 Roughly 999 out of 1000 houses have __________ service entrance wires. 3 Load calculations are part of a home inspection. False Implications of an undersized service include: a. shock hazard b. fire hazard c. shock and fire hazard d. melting insulation e. nuisance tripping of the main fuses and breakers e. What is the largest single-phase service that you are likely to find in a home? 400 amps What size copper wire would you expect to find on the service entrance for: a. 60-amp service b. 100-amp service c. 200-amp service a. 6 gauge b. 4 gauge c. 2-0 gauge Which of the following is a reliable way to identify the service size? a. the size of the service drop wires b. the distribution panel rating c. the service box rating d. the service entrance conductor e. the service entrance conduit size d. Aluminum is an acceptable service entrance conductor material. True or False? True A fused 200-amp service has two 100-amp fuses in the service box. True or False? False If you can't read the size of the fuses in the service box, you should remove them to try to get a better look. True or False? False Which of the following is a safety issue: a. The main fuses have a lower rating than the service entrance wire. b. The main fuses have a higher rating than the service entrance wire. c. The service box has a higher rating than the service entrance wires. d. The service box has the same rating as the service entrance wires. e. The distribution panel has a larger rating than the service entrance wires. b The service box can be inside, outside, or in the garage. True or False? True There can be up to 10 throws to disconnect all the electricity in the house. True or False? False The service box may stand alone or may be combined with the distribution panel. True or False? True List common conditions you might find in a service box.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Florida Home Inspector Exam Questions With
Correct And Complete Solutions
Service entrace conductors run from the service drop to the service box or
service panel. True or False?
True
The service size is determined by the amperage and the voltage ratings of the
service.
True
Is the service drop overhead or underground?
Overhead
Are service laterals overhead or underground?
Underground
The drip loop is typically part of the service drop. True or False?
False
The wire size for the service drop must be the same as the wire size for the
service entrance conductors. True or False?
False
How many wires would you typically find in a 240-volt service drop?
3
What would 4 wires mean?
3-phase electricity
What would 2 wires usually mean?
120 volt service
List 7 common problems with service drops.
1. Overhead wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
4. Wires too close to doors or windows.

,5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.
7. Inadequate clearance from roofs.
List clearances above ground, swimming pools, and roofs.
above roadway--18 ft.
above driveway--12 ft.
above flat roof--8 to 10 ft.
above sloped roof--18 inches
away from water in swimming pool--22.5 ft
3 ft. above sloped roof with pitch > 4 in 12
above walkway--10 ft.
The service entrance conductors run from the _________ to the ___________.
service drop to service box
All service entrance conductors must be in conduit. True or False?
False
All service entrance conductors must be attached above roof level. True or
False?
False
The drip loop should be as close to the roof as possible. True or False?
False
List 10 common problems with service entrance conductors.
1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
5. Mast or conduit rusted.
6. Mast rotted (if wood).
7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.

,List 4 common areas of water penetration into service entrances.
1. conduit joints
2. mast head
3. roof flashing
4. meter base
5. house entry
List 2 functions of the drip loop.
1. Prevents water entry into the conduit or service entrance conductors.
2. Shows that the service drop wires are not straining the splices.
Roughly 999 out of 1000 houses have _________ volts available.
240
Roughly 999 out of 1000 houses have __________ service entrance wires.
3
Load calculations are part of a home inspection.
False
Implications of an undersized service include:
a. shock hazard
b. fire hazard
c. shock and fire hazard
d. melting insulation
e. nuisance tripping of the main fuses and breakers
e.
What is the largest single-phase service that you are likely to find in a home?
400 amps
What size copper wire would you expect to find on the service entrance for:
a. 60-amp service
b. 100-amp service
c. 200-amp service
a. 6 gauge
b. 4 gauge
c. 2-0 gauge

, Which of the following is a reliable way to identify the service size?
a. the size of the service drop wires
b. the distribution panel rating
c. the service box rating
d. the service entrance conductor
e. the service entrance conduit size
d.
Aluminum is an acceptable service entrance conductor material. True or False?
True
A fused 200-amp service has two 100-amp fuses in the service box. True or
False?
False
If you can't read the size of the fuses in the service box, you should remove them
to try to get a better look. True or False?
False
Which of the following is a safety issue:
a. The main fuses have a lower rating than the service entrance wire.
b. The main fuses have a higher rating than the service entrance wire.
c. The service box has a higher rating than the service entrance wires.
d. The service box has the same rating as the service entrance wires.
e. The distribution panel has a larger rating than the service entrance wires.
b
The service box can be inside, outside, or in the garage. True or False?
True
There can be up to 10 throws to disconnect all the electricity in the house. True or
False?
False
The service box may stand alone or may be combined with the distribution panel.
True or False?
True
List common conditions you might find in a service box.

Geschreven voor

Vak

Documentinformatie

Geüpload op
18 januari 2024
Aantal pagina's
115
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$14.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
AcademicSuperScores Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
299
Lid sinds
3 jaar
Aantal volgers
37
Documenten
7648
Laatst verkocht
4 dagen geleden
AcademicSuperScores

NURSING, ECONOMICS, MATHEMATICS, BIOLOGY AND HISTORY MATERIALS. BEST TUTORING, HOMEWORK HELP, EXAMS, TESTS AND STUDY GUIDE MATERIALS WITH GUARANTEE OF A+ I am a dedicated medical practitioner with diverse knowledge in matters Nursing and Mathematics. I also have an additional knowledge in Mathematics based courses (finance and economics)

4.6

156 beoordelingen

5
125
4
9
3
11
2
5
1
6

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen