The Reliability Coordinator just informed you of a slow time error correction which will
begin at the top of the next hour. Your EMS system will not let you change your scheduled
frequency. Your Frequency Bias Setting is -100 MW/.1Hz. What action should you take?

• Increase Net Interchange Schedule by 20 MWs.

• Inform the Reliability Coordinator that you cannot participate in the time error
correction.

• Decrease Net Interchange Schedule by 20 MWs.

• Increase Net Interchange Schedule by 10 MWs.
• Increase Net Interchange Schedule by 20 MWs.
A Balancing Authority has a sudden loss of a large block of load in its area. This loss will
be seen instantaneously in the change of which of the following values?

• Actual Net Interchange
• Scheduled Frequency
• Scheduled Net Interchange
• Area Control Error

• 4 only
• 1&3
• 1&4
• 3&4
C) 1 & 4
Metered Data included in the calculation of ACE are: dynamic schedules, pseudo ties,
actual frequency, and all .

• Tie lines readings
• Generators output
• Scheduled frequency indications
• Transformer load
• Tie lines readings
Balancing Authority A is currently reading a system frequency of 60.00 Hz. Its Net
Actual Interchange is +100 MW and its Net Scheduled Interchange is +200 MW. If
Balancing Authority A's frequency bias setting is 100 MW/0.1 Hz, what is ACE?

,• -100
• 0

• 10
• 100
• -100
A Balancing Authority has a Net Interchange Schedule of -250 MWs from 1200 to 1600 on a
summer day. The Net Interchange Actual for those same hours respectively were - 230 MW, -
275 MW, -250 MW and -270 MW. What was the Balancing Authority's Inadvertent
Interchange for the 4-hour period?

• 6 MWs out
• 25 MWs in
• 25 MWs out
• 6 MWs in
• 25 MWs in
For the ACE equation to work properly, dynamic schedules, pseudo ties, frequency, and all
must be metered.

• Generation
• Communications
• Transformers
• Tie lines
D) Tie lines
If the frequency bias setting is set to a less negative value than the frequency response of a
Balancing Authority and a frequency increase is caused by a sudden loss of load in an
external balancing area, what will be the result?

• The ACE will be zero and will take no AGC action

• The ACE will be a negative value and AGC will increase generation

• The ACE will be a positive value and AGC will lower generation

• This will not affect the ACE
• The ACE will be a negative value and AGC will increase generation
If the frequency bias setting is less negative than the frequency response of a Balancing
Authority and a frequency decline is caused by a sudden loss of generation in an external
balancing area, what will be the result?

• The ACE will be a negative value and AGC will increase generation.

• This will not affect the ACE.

,• The ACE will be a positive value and AGC will lower generation.

• The ACE will be zero and will take no AGC action.
• The ACE will be a positive value and AGC will lower generation.

It is the responsibility of which entity/entities to develop, maintain, and implement load
shedding plans?

• Transmission Operators and Balancing Authorities

• Reliability Coordinator

• Load Serving Entities

• Balancing Authority
• Transmission Operators and Balancing Authorities
A Transmission line is loaded 25% above its SOL. A parallel line is out for routine
maintenance and can be placed in service in 10 minutes. What is the first step the Operator
should take to reduce the line loading?

• Shed load at the downstream bus.

• Open the line.

• Re-Dispatch Generation.

• Initiate the restoration of the parallel line.
D) Initiate the restoration of the parallel line.
As a Transmission Operator, you realize that the voltage level is starting to decline in the
North West part of the system. Which of the following devices should you, as a Transmission
Operator, be able to operate, and/or have another entity operate to raise the voltage level back
to normal in the North West part of the system?

• Transformer Underload Tap Changers
• Shunt Capacitor Banks
• Generator Reactive Output
• All answers are correct
D) All answers are correct
Voltage reduction for load relief should be made on the .

• Distribution system
• Entire Interconnection simultaneously
• Tie-lines with other Balancing Authority Areas
• Transmission System

, • Distribution
system 00:0301:28

• Voltage reduction on the distribution system.
• Shedding all load to arrest frequency
• Shedding load prior to generation tripping
D) Shedding load prior to generation tripping
Failure to meet the DCS criteria of recovery within 15 minutes results in which consequence
for a specified time period for the Balancing Authority's failure to recover?

• Increased Contingency Reserve requirements
• Decertification as a Balancing Authority
• Not allowed to supply regulation services
• Expulsion from the Reserve Sharing Group
• Increased Contingency Reserve requirements
A Balancing Authority foresees or is experiencing conditions where all available resources
are committed to meet firm load, and firm transactions. The BA should request which level
of the Energy Emergency Alerts?

• Energy Emergency Alert Level 2
• Energy Emergency Alert Level 4
• Energy Emergency Alert Level 1
• Energy Emergency Alert Level 3
• Energy Emergency Alert Level 1
Preparations are being made to tie two islands together during restoration. Island "A" has a
frequency of 58.95 Hz and Island "B" has a frequency of 59.97 Hz. What action should be
taken to synchronize the two islands?

• Shed load in Island "B"
• Shed load in Island "A".
• Disable the Synch Check Relay.
• Increase generation in Island "B".
• Shed load in Island "A".
You experience a full system shutdown. You are in the process of restoring load and you
are concerned about re-collapsing the system. Which is the best approach in the restoration
process that will help ensure your system will be restored successfully?

• Maintain frequency between 59.5 HZ and 60.5 HZ.

• If the system has stabilized at below 60 HZ, shed 15% - 20% of the load to raise the
frequency to 61 HZ.

• Avoid energizing loads in excess of 5% of the online generation capacity of the
system.

Written for

Course

Document information

Uploaded on
January 23, 2024
Number of pages
53
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$15.49
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
Hosmerit Chamberlain College Of Nursing
Follow You need to be logged in order to follow users or courses
Sold
352
Member since
2 year
Number of followers
45
Documents
4157
Last sold
2 days ago
HOSMERIT

Welcome to Hosmerit – Your Trusted Source for High-Quality Study Materials Struggling to find reliable and up-to-date resources to help you ace your exams? Look no further. My store offers a wide range of thoroughly researched and well-organized exam guides, test banks, and past papers for various courses and subjects. ✅ Accurate & Up-to-Date – All materials are regularly reviewed to ensure they reflect the most current curriculum. ✅ High-Scoring Content – Get access to study materials that have helped hundreds of students achieve top grades. ✅ Instant Download – Purchase and access your files immediately — no waiting. ✅ Trusted by Students Worldwide – Join a growing number of students who rely on my resources to stay ahead. Whether you're prepping for midterms, finals, or just want to reinforce your understanding, this store is here to help you succeed with confidence.

Read more Read less
4.7

248 reviews

5
220
4
11
3
6
2
4
1
7

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions