NCLE PRACTICE TEST EXAMS WITH ACTUAL CORRECT
QUESTIONS AND VERIFIED RATIONALIZED ANSWERS LATE
UPDATE ALREADY GRADED A+100% GUARANTEED PASS

A Correct Statement regarding epithelial cells is that they:

a)Comprise the posterior layer of the cornea
b)Are unable to regenerate
c)Comprise the thickest layer of the cornea
d) Have the ability to reproduce - Answer d) have the ability to reproduce

Which of the following prescriptions indicates against-the-rule astigmatism?

a)-4.50 +1.00 x75
b)-4.50 +1.00 x 180
c)-4.50 -1.00 x 165
d)4.50 -1.00 x 180 - Answer a)-4.50 +1.00 x75

When a keratometer is being calibrated, which of the following targets will provide the
most reliable result?

a)the single-cut anterior surface of a high-plus lens
b)a perfectly flat highly polished mirror
c) a set of steell balls of known radii
d)the unfinished posterior surface of a low-minus lens - Answer c) a set of steel balls of
known radii

Inadequate movement of a soft lens can be corrected by using a lens that

a) has a steeper base curve
b) has a smaller diameter
c) has a larger diameter
d) has a higher water content - Answer b)has a smaller diameter

A long-term, successful, hydrogel contact lens wearer suddenly develops dry eyes.
Which of the following is most likely to cause this problem?

a) Use of oxidative solution
b) use of rewetting drops
c) use of anti-histamines
d) Wearing of lenses in the wrong eyes - Answer c) use of anti-histamines

During slit-lamp evaluation, on upward gaze, a patient's soft contact lenses move 0.5 to
1mm when the patient blinks. These lenses are:

,a) a good fit
b) too loose
c) too tight
d) too large - Answer a) a good fit

A new daily wearer of soft lenses returns for the first follow up visit with itching, burning,
injected eyes. The most likely cause of these problems is:

a) solution reaction
b) giant-cell papillary conjunctivitis
c) a lens fit that is too loose
d) inability to wear soft lenses - Answer a) solution reaction

Which of the following is the mode of slit-lamp illumination used to view the early stages
of microcystic edema?

a) Retroillumination
b) Direct illumination
c) Parrallelpiped
d) Oscillation - Answer a) Retroillumination

Which of the following changes is best able to improve oxygen transmissibility to a
patient's cornea?

a) Increasing tear exchange
b) Increasing Dk
c) Increasing optical zone diameter
d) Increasing CN bevel - Answer b) Increasing Dk

In using fluorescein to evaluate the fit of a rigid lens of 9.0mm diameter on a typical eye,
a correct statement is that:

a) apical touch with pooling in the PPC curve area is preferred
b) apical toxicity may not be obvious
c) apical pooling with edge touch is recommended
d) apical area, mid-peripheral area, and the lens edges should be assessed - Answer d)
apical area, mid-peripheral area, and the lens edges should be assessed

Which of the following changes would improve a rigid contact lens fit that shows
sluggish movement after 1 hour of wear?

a) Add hyperflange edge treatment
b) Reduce overall diameter
c) Decrease center thickness
d) Increase overall diameter - Answer b) Reduce overall diameter

, Moving a +7.50 RX from the spectacle plane to the corneal plane will require:

a) no change in power
b) more minus power
c) more plus power
d) less plus power - Answer c) more plus power

A fluorescein pattern that has a black area over the corneal apex and a diffuse green
area in the periphery normally indicates:

a) flat fit
b) steep fit
c) normal fit
d) tight fit - Answer a) flat fit

IPC's are used to:

a) provide a transition between the peripheral and base curves
b) reduce edge thickness and lens mass
c) increase the optical zone
d) smooth the lens edge - Answer a) provide a transition between the peripheral and
base curves

A toric soft lens with an RX of -2.00 -1.25 x 120 has the axis resting at the 5 o' clock
position. What should the new axis be when the lens is ordered?

a) 90 degrees
b) 105 degrees
c) 135 degrees
d) 150 degrees - Answer a) 90 degrees

Upon initial insertion of a GP lens, the patient complains about flare. To correct this
problem, the fitter should choose a lens with a/an:

a) increased base curve
b) increased optical zone
c) decreased optical zone
d) flattened base curve - Answer b) increased optical zone

Which curve would a fitter modify to allow more tear flow under the edge of a rigid lens?

a) Posterior peripheral curve
b) Optical curve
c) Anterior peripheral curve
d) Anterior central curve - Answer a) Posterior peripheral curve

Geschreven voor

Vak

Documentinformatie

Geüpload op
1 februari 2024
Aantal pagina's
22
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.19
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Hosmerit Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
349
Lid sinds
2 jaar
Aantal volgers
45
Documenten
4152
Laatst verkocht
14 uur geleden
HOSMERIT

Welcome to Hosmerit – Your Trusted Source for High-Quality Study Materials Struggling to find reliable and up-to-date resources to help you ace your exams? Look no further. My store offers a wide range of thoroughly researched and well-organized exam guides, test banks, and past papers for various courses and subjects. ✅ Accurate & Up-to-Date – All materials are regularly reviewed to ensure they reflect the most current curriculum. ✅ High-Scoring Content – Get access to study materials that have helped hundreds of students achieve top grades. ✅ Instant Download – Purchase and access your files immediately — no waiting. ✅ Trusted by Students Worldwide – Join a growing number of students who rely on my resources to stay ahead. Whether you're prepping for midterms, finals, or just want to reinforce your understanding, this store is here to help you succeed with confidence.

Lees meer Lees minder
4.7

248 beoordelingen

5
220
4
11
3
6
2
4
1
7

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen