EPA 608 universal With correct Answers 2024
EPA 608 universal With correct Answers 2024 Refrigeration technicians who violate the Clean Air Act can: -Answer Lose their EPA certification, be fined, be required to appear in Federal court. After 1995, any supplies of CFC refrigerants to service existing units in the USA can only come from: -Answer recovery and recycling. Refrigerant that is recovered can be returned to: -Answer the same system or other systems owned by the same person without restriction. Refrigerant can not be called "reclaimed" unless it: - .Answer has been chemically analyzed and the refrigerant meets the ARI-700 standard. The EPA can require a technician to demonstrate their ability to perform proper procedures for recovering and/or recycling refrigerant. Failure to demonstrate competency can result in: -Answer revocation of the technicians certification. What characteristic(s) of CFCs make them more likely to reach the stratosphere than most other compounds containing chlorine? -Answer Refrigerants that contain chlorine but not hydrogen are so stable that they do not break down in the lower atmosphere after being released. The chlorine or bromine reacts with the ozone, causing it to change back to oxygen, thus destroying the ozone layer. A system is considered dehydrated when: -Answer the vacuum indicator shows you have reached and held the required finished vacuum. Disposable refrigerant containers are used for ______Answer virgin refrigerant Which refrigerant is an HCFC? -Answer R-123, R-124, R-22 What statement is true about an azeotropic refrigerant mixture? -Answer It is a mixture that acts like a single-component refrigerant over its entire range. Chlorofluorocarbos (CFCs) and hydrochlorofluorocarbons (HCFCs) have which of the following in common? -Answer It is a mixture that acts like a single-component refrigerant over its entire range. To scrap a disposable cylinder, the internal cylinder pressure should be reduced to at least: -Answer 0 psig. Manifold gauge sets are often color coded, when this is done, the high pressure gauge is color coded: - Red.Answer In general, blended refrigerants should be charged: -Answer as a liquid
Written for
- Institution
- EPA 608
- Course
- EPA 608
Document information
- Uploaded on
- February 2, 2024
- Number of pages
- 11
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
refrigeration technicians who violate the clean a
-
refrigerant that is recovered can be returned to
-
refrigerant can not be called reclaimed unless
Also available in package deal