Journeyman Oil Burner Technician 1&2
Oils (Up To 15 GPH) Exam 2024
How long is the emergency replacement chimney forum good for and who's
responsibility is art to see that it is replaced? - ANSWER-90 days

What needs to be preformed before all new heat installations? - ANSWER-Heat loss
and Load calculations

a fill pipe should be how many feet from any building opening? - ANSWER-2 feet

What must be done when preforming an annual tune-up on a heating system? -
ANSWER-Efficiency test/copy posted on site

Whenever a furnace, direct fired hot water heater, or boiler is installed the total
installation must be brought into compliance with what requirements BEFORE appliance
can be fired? - ANSWER-NFPA 31

When outside tanks are used a thermally operated shut off valve must be installed
where? - ANSWER-The supply line enters the inside of the building and where the oil
line enters the room where the appliance is located

When inside tanks are used and the oil supply tank is installed in a separate room, a
thermally shutoff valve must be installed where? - ANSWER-Where the line enters the
room where the appliance is located

Whenever the oil supply is taken from the top of an oil tank a thermally operated wheel
or lever type shut-off valve must be installed where? - ANSWER-At the tank and at the
burner

what can be installed in the supply line but not the return? - ANSWER-Check
Valve/Back flow Preventer

All copper oil supply and return lines must be encased in a continuous piece of no
metallic liquid tight conduit such as PVC, ENT, coated copper tubing. The end of the
conduit shall not exceed how far from any connection except the connection at fuel
tank? - ANSWER-2 inches

In order to avoid undetected oil leaks under floors, the conduit must be how much
bigger than the supply and return lines? - ANSWER-One pipe size larger

An oil line that penetrates a foundation wall must be? - ANSWER-Sealed

, When an oil filter or other accessory equipment is connected to a copper piping smaller
than 3/4 "and is not directly connected to the oil tank or burner the filter or other device
must be what? - ANSWER-Rigidly supported by hangers or mounted brackets

What must supply and return lines be connected with? - ANSWER-Flare fittings

What fittings shall not be used unless for introduction of lines at top of the tank with a
single or double tap bushing? - ANSWER-Compression

All connections of supply or return oil lines located outside must be made with what? -
ANSWER-Flare frost fittings

All fuel oil supply tanks must be a minimum of how many feet from any gas or solid fuel
burning appliance? - ANSWER-5 feet

all outside tanks should NOT be installed on? - ANSWER-Wood or combustable
material

All oil supply tanks must be liquid tight. Leaking tanks may be temporarily repaired with
a tank patch, this patch is good for how long? - ANSWER-30 days

For steam safety or pressure relief valves which terminate inside the structure must
terminate how far above the floor? - ANSWER-6 to 12 Inches

Steam safety and pressure relief valves on boilers must be installed with the spindle in
what position? - ANSWER-upright vertical position

How far should oil burners be installed from an electrical panel? - ANSWER-3 ft

How far should oil burners be installed from an unenclosed fuel oil tank? - ANSWER-5 ft

Screens used in louvers and grilles shall not be smaller than? - ANSWER-1/4" mesh

Two or more oil burning appliances shall be permitted to be connected to a single
chimney when? - ANSWER-When there is adequate draft

What shall be provided for each oil burning appliance that is connected to a chimney or
power vent, unless designed, conditions of install, or combination, or appliance is listed
for use without one? - ANSWER-Draft regulator

What size should a chimney connector be? - ANSWER-As short as possible

For natural draft appliances the horizontal length of chimney connector shall not exceed
how many feet? - ANSWER-10 ft

Geschreven voor

Vak

Documentinformatie

Geüpload op
27 februari 2024
Aantal pagina's
5
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$8.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
Tsavorite

Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
Tsavorite chamberlain college of nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
-
Lid sinds
2 jaar
Aantal volgers
0
Documenten
149
Laatst verkocht
-

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen