Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

NCLE Advanced Certification Exam – Questions & Answers

Rating
-
Sold
-
Pages
154
Grade
A+
Uploaded on
29-02-2024
Written in
2023/2024

NCLE Advanced Certification Exam – Questions & Answers NCLE Advanced Certification Exam – Questions & Answers NCLE Advanced Certification Exam – Questions & Answers NCLE Advanced Certification Exam – Questions & Answers NCLE Advanced Certification Exam – Questions & Answers NCLE Advanced Certification Exam – Questions & Answers

Show more Read less
Institution
Course

Content preview

NCLE Advanced Certification Exam Questions and
Answers Already Passed

1. The sagittal depth of a rigid gas permeable contact lens can be altered without changing the
diameter by:


A. Changing the power
B. Changing the edge design
C. Changing the radius of curvature of the anterior optical zone

D. Changing the radius of curvature of the posterior optical zone -Answer✅ The answer is D.


The posterior optical zone will directly affect the lens to cornea relationship of a rigid gas
permeable lens. If the posterior optical zone is steepened, it will increase the sagittal depth. If it
is flattened, it will decrease the sagittal depth. Changing the power, which is accomplished by
changing the anterior optical zone, will not affect the sagittal depth of the lens, nor will
changing its edge design.


2. A truncation is used on a rigid gas permeable contact lens to help enhance the performance
of which type of design?


A. Bifocal
B. Aphakic
C. Bitoric

D. Keratoconus -Answer✅ The answer is A.


A lens is truncated by removing a segment of the lower edge of a contact lens. This creates a
straight edge that interacts with the lower lid and aids in lens positioning. Of the lens designs
listed in the question, the only one that requires precise positioning of its optical portions is a
translating bifocal lens.


3. The mass of an aphakic rigid gas permeable contact lens can be reduced by making the lens
design:

,A. Spherical
B. Lenticular
C. Tricurve

D. Aspheric -Answer✅ The answer is B.


A lenticular or myoflange design will decrease the mass of an aphakic lens as well as increase
the edge profile, which allows it to interact more with the upper lid and aid in positioning of the
lens.


4. In order to tighten the fit of a rigid gas permeable lens you can:
I. Increase the optical zone diameter
2. Decrease the optical zone diameter
3. Increase the overall lens diameter
4. Use a prism ballasted lens design


A. 3 only
B. 1&3
C. 2 only

D. 2&3 -Answer✅ The answer is B.


Increasing the optical zone diameter and increasing the overall lens diameter will both tighten
and steepen the relationship of the lens to the cornea. Decreasing the optic zone diameter will
serve to flatten and loosen the lens to cornea relationship. Using a prism-ballasted lens design
will not affect the lens to cornea relationship as it relates to sagittal depth.


5. A high minus rigid gas permeable lens will be thin centrally with relatively thick edges. To
reduce the edge thickness, and increase overall comfort, use:


A. Aspheric peripheral curves

,B. A myoflange
C. A higher Dk material

D. A hyperflange -Answer✅ The answer is D.


A hyperflange will decrease edge thickness as well as lens awareness . Aspheric peripheral
curves change the posterior design of the lens but do not reduce edge thickness. A higher Dk
material will not change the overall lens edge thickness. A myoflange will actually add thickness
to the lens edge and is used for high plus lenses not high minus lenses.


6. To add minus power to a rigid contact lens with a rotating modifying spindle, one would:


A. Polish the posterior surface of the rigid lens
B. Polish the mid peripheral anterior surface
C. Polish the central anterior surface

D. Polish the peripheral anterior surface -Answer✅ The answer is C.


One would rarely polish or attempt to manipulate the central posterior surface of a rigid lens.
Applying polishing pressure to the mid-peripheral and the peripheral anterior surface would add
plus power. Applying polishing pressure to the central anterior surface would add minus power.


7. Which lens design would provide the best visual acuity for a patient with the following
information?
K's 42.00@ 180/ 42.50@90
Rx -6.75 +1.75 cx 90


A. Front surface toric rigid gas permeable
B. Spherical rigid gas permeable
C. Soft sphere

D. Bitoric rigid gas permeable -Answer✅ The answer is A.

, The keratometer readings indicate the need for a spherical back surface, which would rule out
the use of a bitoric lens. A soft spherical lens would not correct the moderate amount of
refractive astigmatism that is present, nor would the spherical rigid gas permeable lens. A front
surface toric RGP would best meet this patient's needs since it has a spherical back surface, but
has a toric front surface which would correct the residual astigmatism.


8. Which of the following describes the angle that the edge of a bead of water makes with the
surface of a plastic?


A. Wetting angle
B. Surface angle
C. Bead angle

D. Reflection angle -Answer✅ The answer is A.


The wetting angle of a rigid gas permeable material describes how a fluid spreads over the
surface. It is important to remember, however, that wetting angle is a description of the
material outside of the patient's natural ocular environment. Within minutes of insertion, a rigid
lens is encapsulated in the natural tear mucin and the wetting angle of the material is no longer
important.


9. If a patient has 1.50 D of refractive cylinder and keratometer readings of 44.00@ 180/ 44 .50
@ 90, a spherical rigid gas permeable lens will:


A. Give the patient their best correctable vision
B. Usually result in residual astigmatism
C. Fit poorly

D. Be uncomfortable -Answer✅ The answer is B.


The back surface of a rigid lens will usually correct only the astigmatism that is found on the
surface of the cornea. Therefore, when there is significantly more astigmatism in the refraction
than on the surface of the cornea, residual astigmatism is anticipated.


10. If a patient has spherical K readings of 43.50 and an Rx of -4.00 +1.75 cx 90, the patient has:

Written for

Course

Document information

Uploaded on
February 29, 2024
Number of pages
154
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$17.29
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller
Seller avatar
Tsavorite

Also available in package deal

Get to know the seller

Seller avatar
Tsavorite chamberlain college of nursing
Follow You need to be logged in order to follow users or courses
Sold
-
Member since
2 year
Number of followers
0
Documents
149
Last sold
-

0.0

0 reviews

5
0
4
0
3
0
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions