NYC MASTER ELECTRICIAN EXAM (Electrical exam) QUESTIONS WITH 100% COMPLETE ANSWERS. Type ____ is multiconductor cable identified for use as underground service entrance cable. Type USE cable Knife switch rated for more than 1200 Amps at 250Volts or less Can be used only as isolating switch, shall not be opened under load Track lighting with outlets in a bathroom is not allowed because ? Track lighting has receptacle Where internal combustion engines are used as the prime motor, an on site fuel supply shall be provided with an on premise fuel supply sufficient for not less than ____ hours full demand operation of the system 6 hours Fixed in place X-ray equipment properly supplied by a branch circuit rated at not over ____ amperes shall be permitted to be supplied through a suitable attachment plug cap and hard service cable cord. 30 Amps Where skin effect exist the ferromagnetic envelope shall be bonded at ____. Both ends GFCI protection at a carnival is not required for equipment at circuit if the receptacle is of the ____type. Locking The maximum voltage drop from service point to the last over-current device in a dwelling unit? 4% Which of the following statements best describe the grounding requirement for central vacuum outlet Accessible non current carrying metal parts are required to be connected to an equipment grounding conductor. In healthcare facilities, patient bed receptacles located in general care areas shall be supplied by at least two branch circuits, which ____permitted to originate from two separate transfer switches on the emergency system Are permitted Patient care areas of healthcare facilities ____ areas such as business offices, corridors, lounges ,day rooms, or similar areas Do not include The patient care area is any portion of the healthcare facility where patients are intended to be ____or ____. Examined or treated Each general care area patient bed location in a healthcare facility must be provided with four ____ or ____ duplex receptacles Single or two A hospital is a building or portion thereof used for medical, psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more patients Four Where installed to reduce electrical noise for electronic equipment, electrical continuity of the metal raceways shall not be required and metal raceway can terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment Listed fitting Feeder and branch circuit conductors within ____ inches of a Ballast shall have an insulation temperature rating not lower than 90°C (194°F) unless supplying a luminaiere marked as suitable for a different insulation temperature 3 inches Manufactured wiring systems constructed with type MC cable shall be supported and secured at intervals not exceeding ____ ft. 6 ft Where a main bonding jumper or a system bonding jumper is a screw only the screw shall be identified with a ____ that shall be visible with the screw installed Green finish Plug fuses a 15 amperes and lower rating shall be identified by a ____ configuration of the window, cap, or other prominent part to distinguish them from fuses of higher ampere rating Hexagon The load for household electric clothes dryer's in a dwelling unit(s) shall be either ____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each dryer served ? 5000 watts Service conductors installed as unjacketed multiconductor cable shall have a minimum clearance of ____ windows that are designed to be opened, doors, porches, stairs fire escape or similar locations. 3 ft (36 inches) —— Cartridge fuses of the renewable type shall be permitted to be used only for replacement in existing installation is where there is no evidence of over-fusing or tampering. Class H Branch circuit conductors within ____inches of the ballast shall have an insulation temperature rating not lower it 90°C 194°F 3" inches The minimum radius of a field bend on trade size 1 "1/4 RMC is ____. 8 In a dwelling unit which appliance is allowed to have a 24"inch cord with Attachment ground plug ? Combination range hood/microwave oven Type 3 Surge Protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment ____ the type 3 SPD connection must be a minimum 30'ft of conductor a distance from the service or separately derived system disconnect Included in the manufactures instructions Which flexible cable is Allowed to be used for electric vehicle charging station 300 Volts ? EVJ Type ____ fuse adapters shall be designed so that once inserted in a fuse holder that cannot be removed Type S fuse Service drops Installed over roof shall have a vertical clearance of ____ above the roof surface, and unless a lesser distance is permitted by and exceptions 8'ft Class 2 and Class 3 circuits shall not be placed in any enclosure, raceway, cable, or similar fittings with conductors of Class 1 or electric light or power conductors, unless ____. Separated by barrier In the critical care areas of health care centers, each patient bed shall be provided with a minimum of ____ duplex receptacles 3 duplex (6 single) The equipment system shall supply major electric ____ necessary for patient care and basic hospital operation Equipment The essential electrical system in a healthcare facility shall be compromised of the emergency system and the: equipment system Locations were flammable anesthetics are employed are class I,Division I locations that shall extend upwards to a level 5'ft above the floor In a healthcare facility receptacles and attachment plugs in a hazardous (classified) location with an anesthizing area shall be listed for use in class I group ____ locations Group C In anesthetic,areas health care equipment frequently in contact with bodies of persons shall not exceed ____ volts. 10 Volts In anesthetic areas, low-voltage equipment that is frequently in contact with the bodies of persons or has exposed current-carrying elements shall operate on an electrical potential of 10 volts or less,be moistur- resistant, be approved as intrinsically safe or double-insulated equipment. In a healthcare facility, the maximum internal current permitted to flow through a line isolated monitor,when any point of the isolated system is grounded, shall be ____ . 1 milliamperes Transfer eguipment, including automatic transfer switches,shall be automatic, identified for emergency use , approved by the authority having jurisdiction Automatic transfer switches shall be ____ operated and ____ held Electrically operated and mechanically Audible and visual signal devices for an emergency system shall be provided,where practicable, for the purpose(s) of indicating that the battery is carrying load, derangement of emergency source, that the battery charger is not functioning Wiring from an emergency source to emergency loads shall ____ ____ ____ ____ of all other wiring Be kept entirely independent of all other wiring Emergency circuit wiring shall be permitted to enter which of the following types of equipment with normal circuit wiring? Transfer switches, exit or emergency luminaries supplied from two sources Emergency circuit wiring must be designed and located in such a manner so as to minimize the possibility of failure because of ____, ____, ____. Vandalism,flood,fire. Emergency lighting emergency power or both must be available in the building within a time not exceeding ____seconds 10 seconds A storage battery supplying emergency lighting and power shall maintain not less than 87.5% of full fault is that total low for a period of at least 1.5 hours Where an internal combustion engine is used as the prime mover for the emergency system and on-site fuel supply shall be provided for not less than 6 hours of full-demand operation of the system Unit equipment (battery packs) shall be on the same branch circuit as that serving the normal lighting in the area and connected ahead of any local switches The alternate source for emergency systems shall not be required to have ground-fault protection of equipment with automatic disconnecting means They equipment grounding terminal buses of the normal and essential branch-circuit panelboards serving the same individual patient care vicinity shall be connected together with an insulated continuous copper conductor not smaller than 10 AWG Each patient bed location in critical care areas shall be supplied by at least 2 branch circuits. Individual branch circuit shall not be required for portable mobile and transportable medical x-ray equipment requiring a capacity of not over 60 amperes The ampacity of supply branch circuit conductors and the current rating of all the current protective devices for x-ray equipment shall not be less than 50 of the momentary rating or 100 percent of the longtime rating, whichever is greater There shall be a minimum of one 20A branch circuit for laundry outlets required by 210.52(f) Indoor electrical vehicle charging sites, unless specifically listed for the purpose and location,the coupling means of the electric vehicle supply equipment shall be stored or located at a height of not less than 18"Inches and not more than 4'FT Type 3 surge protective devices can be installed on the load side of a branch circuit overcurrent device up to the equipment served. If included in the manufacture's instructions, the type 3 SPD connection must be a minimum 30ft. Of conductor distance from the service or separately derived system disconnect

Show more Read less
Institution
Course

Content preview

NYC MASTER ELECTRICIAN EXAM (Electrical exam)
QUESTIONS WITH 100% COMPLETE ANSWERS.
Type ____ is multiconductor cable identified for use as underground service
entrance cable.
Type USE cable
Knife switch rated for more than 1200 Amps at 250Volts or less
Can be used only as isolating switch, shall not be opened under load
Track lighting with outlets in a bathroom is not allowed because ?
Track lighting has receptacle
Where internal combustion engines are used as the prime motor, an on site fuel
supply shall be provided with an on premise fuel supply sufficient for not less
than ____ hours full demand operation of the system
6 hours
Fixed in place X-ray equipment properly supplied by a branch circuit rated at not
over ____ amperes shall be permitted to be supplied through a suitable
attachment plug cap and hard service cable cord.
30 Amps
Where skin effect exist the ferromagnetic envelope shall be bonded at ____.
Both ends
GFCI protection at a carnival is not required for equipment at circuit if the
receptacle is of the ____type.
Locking
The maximum voltage drop from service point to the last over-current device in a
dwelling unit?
4%
Which of the following statements best describe the grounding requirement for
central vacuum outlet
Accessible non current carrying metal parts are required to be connected to an
equipment grounding conductor.
In healthcare facilities, patient bed receptacles located in general care areas shall
be supplied by at least two branch circuits, which ____permitted to originate from
two separate transfer switches on the emergency system
Are permitted
Patient care areas of healthcare facilities ____ areas such as business offices,
corridors, lounges ,day rooms, or similar areas
Do not include
The patient care area is any portion of the healthcare facility where patients are
intended to be ____or ____.
Examined or treated
Each general care area patient bed location in a healthcare facility must be
provided with four ____ or ____ duplex receptacles
Single or two

, A hospital is a building or portion thereof used for medical,
psychiatric,obstetrical , or surgical, care on a 24 hour basis of ____ or more
patients
Four
Where installed to reduce electrical noise for electronic equipment, electrical
continuity of the metal raceways shall not be required and metal raceway can
terminate a (an) ____ nonmetallic fitting or spacer on electronic equipment
Listed fitting
Feeder and branch circuit conductors within ____ inches of a Ballast shall have
an insulation temperature rating not lower than 90°C (194°F) unless supplying a
luminaiere marked as suitable for a different insulation temperature
3 inches
Manufactured wiring systems constructed with type MC cable shall be supported
and secured at intervals not exceeding ____ ft.
6 ft
Where a main bonding jumper or a system bonding jumper is a screw only the
screw shall be identified with a ____ that shall be visible with the screw installed
Green finish
Plug fuses a 15 amperes and lower rating shall be identified by a ____
configuration of the window, cap, or other prominent part to distinguish them
from fuses of higher ampere rating
Hexagon
The load for household electric clothes dryer's in a dwelling unit(s) shall be either
____ watts (volt-amperes) or the nameplate rating, which ever is larger, for each
dryer served ?
5000 watts
Service conductors installed as unjacketed multiconductor cable shall have a
minimum clearance of ____ windows that are designed to be opened, doors,
porches, stairs fire escape or similar locations.
3 ft (36 inches)
—— Cartridge fuses of the renewable type shall be permitted to be used only for
replacement in existing installation is where there is no evidence of over-fusing
or tampering.
Class H
Branch circuit conductors within ____inches of the ballast shall have an
insulation temperature rating not lower it 90°C 194°F
3" inches
The minimum radius of a field bend on trade size 1 "1/4 RMC is ____.
8
In a dwelling unit which appliance is allowed to have a 24"inch cord with
Attachment ground plug ?
Combination range hood/microwave oven
Type 3 Surge Protective devices can be installed on the load side of a branch
circuit overcurrent device up to the equipment served.if ____ the type 3 SPD
connection must be a minimum 30'ft of conductor a distance from the service or
separately derived system disconnect

Written for

Course

Document information

Uploaded on
March 7, 2024
Number of pages
15
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$14.48
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
QUICKEXAMINER Walden University
Follow You need to be logged in order to follow users or courses
Sold
92
Member since
2 year
Number of followers
44
Documents
5418
Last sold
3 weeks ago
QUICK EXAMINER

Looking for high-quality study materials to help you excel? You’re in the right place! I provide well-structured notes, summaries, essays, and research papers across various subjects, all designed to make studying easier and more efficient. Why Choose My Materials? ✔ Comprehensive and well-organized content ✔ Easy-to-understand explanations ✔ Time-saving summaries for exams and research ✔ Carefully curated to ensure accuracy and clarity Each document is crafted to provide valuable insights, helping you grasp concepts quickly and effectively. Whether you're preparing for exams, writing an assignment, or just need clear and concise notes, my resources will support your academic journey. Browse my collection and take your studies to the next level

Read more Read less
3.6

15 reviews

5
5
4
5
3
2
2
0
1
3

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions