Open Book Exam #2 When using the interior metal water piping system for the grounding electrode, the connection of the grounding electrode to the water piping system must be made ___. 15 and 20 amp single phase 125 volt receptacles, installed on a boat-yard wharf, for general use shall be ___. The working clearance in front of a 2300 volt switchboard to a wooden wall is ___. The terminal bar in a panelboard is connected to the neutral bar only when the panelboard is used as ___. Wire terminals located in panelboards shall be arranged ___. The minimum allowed rating for the service disconnect of a single circuit installation is ___. The service grounding electrode conductor is sized by the rating of the ___. The maximum distance that a SE cablestrap can be from the meter base or service head is ___. The Code defines "unfinished basement" as portions or areas of the basement ___. The maximum size rigid metal conduit allowed for electrical construcion is ___. Appliance outlets installed for a specific appliance shall be installed within ___ of the intended location of the appliance. Type NMC cable may be used in ___. MI cable is prohibited ___ The maximum overcurrent protection for a #14 copper THHN wire installed in a raceway is ___ amperes. Conductors that are paralleled, are ___. Temporary wiring used on a construction project shall be removed ___. When receptacles are connected to circuits having different voltages, frequencies, or types of current (AC or DC) on the same premises, ___. The maximum voltage allowed to supply listed electric-discharge lighting in residences, hotels, motels and similar occupancies is ___. When outside overhead wiring is used, with no messenger cable, the minimum size copper wire allowed for spans up to 50 feet is ___. For the purpose of calculating branch-circuit and feeder loads, ___ is not a nominal system votage. Feeders containing a common neutral are permitted to supply ___ sets of 4-wire feeders. A 125 volt, 15 or 20 amp receptacle shall be installed for the servicing of heating, air conditioning and refrigeration equipment in ___. Cable tray systems shall not be used ___. Wall-switched controlled receptacles in dwelling units in lieu of lighting outlets are allowed in all habitable rooms except ___. Receptacles installed in a guest room of a motel ___. Dry-type transformers must be readily accesible except for ___. When a capacitor contains ___ of flammable liquid, it shall be enclosed in a vault or an outdoor fenced enclosure. The maximum voltage between conductors for lighting fixtures in a swimming pool is ___. When the following condition(s) are met ___, a room air conditioner is considered to be a single motor unit in determining its branch circuit requirements. The function of the motor overcurrent protective device is ___.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Open Book Exam #2

1). When using the interior metal water piping system for the grounding electrode, the
connection of the grounding electrode to the water piping system must be made ___.

 Ans: (d) within the first five feet entering the building 250.2(A1)


2). 15 and 20 amp single phase 125 volt receptacles, installed on a boat-yard wharf, for general
use shall be ___.

 Ans: (b) GFCI protected 555.19(B1)


3). The working clearance in front of a 2300 volt switchboard to a wooden wall is ___.

 Ans: (b) 36" T. 110.34(A)


4). The terminal bar in a panelboard is connected to the neutral bar only when the panelboard
is used as ___.

 Ans: (b) service euipment 250.24(A)


5). Wire terminals located in panelboards shall be arranged ___.

 Ans: (d) so it will not be necessary for service personnel to reach across or beyond an
uninsulated ungrounded line bus to make connections 408.3(D)


6). The minimum allowed rating for the service disconnect of a single circuit installation is ___.

 Ans: (a) 15 amps 230.79(A)


7). The service grounding electrode conductor is sized by the rating of the ___.

 Ans: (d) service-entrance conductors T. 250.66




PaperStoc.com Page 1 of 6

, 8). The maximum distance that a se cablestrap can be from the meter base or service head is
___.

 Ans: (b) 12" 230.51(A)


9). The code defines "unfinished basement" as portions or areas of the basement ___.

 Ans: (d) limited to storage or work areas 210.8(A5)


10). The maximum size rigid metal conduit allowed for electrical construcion is ___.

 Ans: (b) 6" 344.20(B)


11). Appliance outlets installed for a specific appliance shall be installed within ___ of the
intended location of the appliance.

 Ans: (c) 6' 210.50(C)


12). Type nmc cable may be used in ___.

 Ans: (a) dry or moist locations 334.10(B)(1)


13). Mi cable is prohibited ___

 Ans: (d) where exposed to destructive corrosive conditions 332.12(2)


14). The maximum overcurrent protection for a #14 copper thhn wire installed in a raceway is
___ amperes.

 Ans: (b) 15 240.2(D)(3)


15). Conductors that are paralleled, are ___.

 Ans: (d) electrically joined at both ends 310.4(A)


16). Temporary wiring used on a construction project shall be removed ___.

 Ans: (a) immediately upon completion of the construction 590.3(D)


17).



PaperStoc.com Page 2 of 6

Geschreven voor

Vak

Documentinformatie

Geüpload op
9 maart 2024
Aantal pagina's
6
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$12.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
Academik001 Exam Questions
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
16
Lid sinds
3 jaar
Aantal volgers
10
Documenten
2263
Laatst verkocht
1 jaar geleden

Buy Best Exam Answers

4.0

2 beoordelingen

5
1
4
0
3
1
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen