FDNY F-80 Fire Safety & Alarm Systems in Homeless Shelters Exam Questions With 100% Correct Answers.
FDNY F-80 Fire Safety & Alarm Systems in Homeless Shelters Exam Questions With 100% Correct Answers. GOOD As the F-80 C of F holder, you notice a minor defect in the fire protection system and report it to the building owner. In the event the issue is still not corrected three months later, what would be the next step that you are required to take? Report the defect in writing to the Fire Department GOOD Typical causes of fires in homeless shelters are considered which of the following? - Halogen lamps - Unattended and prohibited microwaves - Overloaded extension cords GOOD Shelter staff members shall be readily identifiable at all times while on duty by means of an approved identification such as a: - Nameplate - Cap, armband - Uniform Aisles spaces in shelters shall not be less than 36 inches in width, EXCEPT that cross aisles (aisle space in the main hallways) are required not to be less than how many inches in width? 48 inches 6.- ________________ involves using a keyed switch to recall the affected elevator bank non-stop to the lobby or sky lobby during a fire condition. ?????? Phase l Coordinators of Fire Safety & Alarm Systems in Homeless Shelters should be familiar with which of the following procedures while on duty? - Ensure that all required log books are updated and kept on the premises in a secure area. - Must receive training and be highly proficient on the Fire Alarm Control Panel. - Take proper steps upon the discovery of a fire protection system impairment. What type of fire extinguisher should be used if a kitchen grease fire starts in a homeless shelter? Class K What would be considered an example of an UNPLANNED OUT OF SERVICE CONDITION? - Break or major leak in the sprinkler system - Empty gravity tank - Inoperative or shut water supply valves If a fire alarm system is transmitted immediately after pulling down on the cover of a manual pull station, that person has used a _________ pull station. Single action station The clearance between the bottom of a portable fire extinguisher and the floor must be at least __________ inches. ??? 4
Geschreven voor
- Instelling
- FDNY F-80 Fire Safety & Alarm Systems in Homeless
- Vak
- FDNY F-80 Fire Safety & Alarm Systems in Homeless
Documentinformatie
- Geüpload op
- 30 maart 2024
- Aantal pagina's
- 7
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Onbekend
Onderwerpen
-
fdny f 80 fire safety alarm systems in homeless