C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam Latest 2022 Already Passed (OFFER)
C.S. Certification Exam, SPD Test, Sterile Processing Study Material for Certification Exam Latest 2022 Already Passed Which area is the first to accept responsibility for all supplies in the facility? Receiving Which type of inventory distribution system requires the use of a pre-determined inventory list? Par Level Just-in-time distribution systems are also known as Stockless Distribution Ordering the optimum quantity of an item based on historical data is known as Economical Order Quantity Which of the following are elements of a distribution system? patient charging, storage, and receiving The most efficient distribution system is the Total exchange cart The computerized locked supply system is a variation of the Par Level Which distribution system requires the using department to be responsible for maintaing inventory levels? Demand An ongoing inventory management system is known as a Perpetual Inventory System In which distribution system are requisition filled and delivered as they are received? DemandInventory performance" (a rough indication of the effectiveness of the inventory system) is evaluated by percent of back order, availability of critical items, and inventory turnover Which of the following is the MOST efficient and cost-effective method for inventory control in the SPD ordering and data generation? Computerized Inventory Control System The temperature in the sterile storage are should not exceed 75º F (24º C) Shelving in the sterile storage area must be kept how far from the outside walls? 2 inches The thickness of a sterility maintenance cover should be 2 to 3 mils The minimum number of air exchanges per hour in the sterile storage area should be 4 The relative humidity in the sterile storage area should not exceed 70% Approximately how much space should be left between and item and the inside edges of a peel pouch? 1 inch What is the maximum size and weight of a textile pack? 12" x 12 x 20" 12 pounds Which of the following packaging materials is acceptable for low-temperature gas plasma and ozone sterilization Tyvek Basin sets should be prepared for sterilization with an absorbent material between each basin Tamper-evident seal on rigid containers include latches and locksWhat is the acceptable temperature range for the prep and packaging area? 68º F-73º F (20º- 23º C) The preparation and packaging area must have an air exchange rate of 10 per hr If a non-perforated tray is used for the sterilization of instrument sets, it must be Tilted on the sterilizer rack The ideal humidity level in the preparation and packing area should be 50% For sterilization, rigid containers must be placed flat Which of the following packaging materials is acceptable for steam sterilization? Non-woven wraps Re-passivation of an instrument can be achieved by routine lubrication What is the most difficult part of a hemostat to clean? box lock Which of the following lubricants is recommended for use on surgical instruments? petroleumbased What type of finish on a surgical instrument is used for laser procedures? ebonized What is the final stage in manufacturing a surgical grade instrument? passivation Which series of stainless steel is used is to manufacture malleable retractors? 300 The weakest part of the instrument is/are the box locksThe layer on a surgical instrument created by the passivation process is called chromium oxide A crack in a hand-held instrument would most likely be found in the box lock The appropriate sterilization cycle for an autoclave load containing a basin set, a minor surgery set, and twelve towel packs is 270 F (132 C ) for 4 minutes, 30 psi and 20 minutes drying time Cotton gauze cannot be used in which sterilization process? low temperature gas plasma Which agencies are involved with the regulation and control of ethylene oxide when it's used as a sterilant? environmental protection agency, food and drug administration, and centers for disease control and prevention Which of the following sterilization methods would be appropriate for petrolatum gauze dressings? dry heat To eliminate the bioburden on metal surgical instrument within the SPD, the MOST cost-efficient sterilization method is generally considered to be steam under pressure There are two pressure gauges on a steam sterilizer. These gauges measure the pressure in the jacket and chamber What is the maximum number of 100% EO cartridges permitted by OSHA to be stored outside of a flammable goods cabinet? 10 At the end of the sterilization cycle, the EO cartridges and the gloves used to handle them should be Aerated
Written for
- Institution
- C.S. Certification
- Course
- C.S. Certification
Document information
- Uploaded on
- April 11, 2024
- Number of pages
- 41
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
sterile processing
-
offer
-
cs certification exam spd test