Security Guard F-80 Latest Exam
Security Guard F-80 Latest Exam Building Occupants All persons in the shelter, including employees, clients, staff and visitors. Alarm Silence Switch is used to silence the building audible and visual devices after evacuation is complete while the source of the alarm is being investigated. Carbon Monoxide Alarm A single or multiple-station alarm responsive to carbon monoxide, containing a build-in initiation sensor, audible sounder (notification device), and power supply And is not connected to a system. Carbon Monoxide Detector - An automatic device that senses carbon monoxide and is connected to the fire alarm control panel. Requires in building that has fossil, gas and oil. shall be installed, tested, and maintained by qualified personnel. Central Station Company A facility that receives alarm signals from a protected premise and retransmits or otherwise reports such alarm signals to the FDNY. Coordinator of Fire Safety & Alarm Systems in Homeless Shelters F-80 Certificate of Fitness holders; also referred to as Coordinator of Fire Safety & Alarm Systems throughout this study material. Evacuation the emptying of a building of all building occupants in response to a fire or other emergency. Emergency Preparedness Plan is also known as the fire safety and evacuation plan and/or emergency action plan. A copy of the emergency preparedness plan must be maintained and be available at all times to Fire Department Fire Alarm System any system, including any interconnected fire alarm sub- system, of components and circuits arranged to monitor and annunciate the status of fire alarm or supervisory signal-initiating devices. Classified as automatic, manually activated or both. Lamp Test This function is used on some FACP's to check the condition of the light emitting diodes (LEDs) on the FACP. Fire and Emergency Preparedness (FEP) Staff - The individuals identified in the emergency preparedness plan (also known as the fire safety and evacuation plan or emergency action plan) as responsible for the implementation of such plan. fire drill a practice of the emergency procedures to be used in case of fire or non fire emergency. Drills in homeless shelters should be conducted monthly on each shift. It shall be conducted at varying time of the day. Fire Guard A person holding a certificate of fitness for such purposes , who is trained in and responsible for maintaining a fire watch and performed fire safety duties Fire Protection System System, devices, equipment approved and designed to protect structure and minimize loss due to fire. Fire Triangle fuel, oxygen, heat are the three parts of the fire triangle, to be sustained. If one is removed, the fire will extinguish. Three stages of fire incipient, free burning, smoldering Incipient Stage of a Fire Fire which is in the initial or beginning stage which can be controlled or extinguished by portable fire extinguisher Free Burning Stage of a Fire The fully developed stage of a fire. This is the second stage of the three stages of a fire. Generally during this stage the entire room and all of its contents are burning. Smoldering Stage of Fire - The decay stage of a fire. This is the third stage in the three stages of a fire. This occurs when the fire has an unlimited supply of fuel but limited oxygen. Visible flames will have diminished and the fire will smolder and continue to produce smoke and toxic gases, particularly carbon monoxide. In-Building Relocation the controlled movement of building occupants from an endangered area of a building to an in-building relocation area within the same building in response to a fire or non-fire emergency. In-Building Relocation Area (IBRA) a designated area in a building to which building occupants may be relocated to in accordance with the emergency preparedness plan for the premises. Manual Fire Alarm Box A manually operated device used to initiate an alarm signal. Non-Fire Emergency A training exercise by which building occupants are familiarized with and/or practice the procedures for safe, orderly and expeditious sheltering in place, in-building relocation, partial evacuation or evacuation, or combination thereof, in the event of a non-fire emergency, in accordance with the emergency preparedness plan for the premises. Off-Line Those periods of time when a Central Station Company will, at the request of a building owner, not transmit fire alarm signals received from a building to the Fire Department. One-way Voice Communication is a public address system that is capable of making announcements from the fire command center to all parts of the buildings. It can be used to warn and instruct building occupants in case of a fire or non-fire emergency. Out of service signage: Impairment coordinators shall notify their supervisor and put a placard (tag) over a defective device, indicating that it is out of service. Out of service system: A fire protection system that is not fully functional; or whose operation is impaired or is otherwise not in good working order. Partial Evacuation the emptying of a building of some but not all building occupants in response to a fire or an emergency. Phase I Emergency Elevator Recall (Phase I) involves using a keyed switch to bring the elevators back to the lobby or sky lobby. This will cause the elevator car to return non-stop and without opening the doors to the lobby or sky lobby. Phase II Emergency In-Service Elevator Operation (Phase II) involves turning the elevator car switch to the "Firemen Service" position. This results in manual operation of the elevators and overrides any other keyed switch controls and elevator landing call buttons. Public Address System An electronic amplification system, used at an aquatic facility so that announcements can be easily heard. Shelter Clients the population that lives in homeless shelters Shelter in Place the precaution of directing building occupants to remain indoors, at their present location, in response to a fire or non-fire emergency. Smoke Alarm a device that produces a loud warning noise in the presence of smoke. Not connected to a system. Smoke Detector -An automatic device that senses smoke and is connected to the fire alarm control panel. Two-way Voice Communication a form of transmission in which both parties involved have the ability to transmit information. uses warden phones that are placed at several locations throughout the building, usually near the exit stairways in the building. Unnecessary Alarm An alarm signal transmitted by a fire alarm system which functioned as designed, but for which a department response proved unnecessary. Example: lit cigarette in a non-smoking area, Unwarranted Alarm
Written for
- Institution
- F-80
- Course
- F-80
Document information
- Uploaded on
- April 15, 2024
- Number of pages
- 7
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
security guard f 80 latest exam building occupant