AMMUNITION AND EXPLOSIVES STORAGE SAFETY (CERT) (AMMO 112) EXAM QUESTIONS WITH COMPLETE SOLUTIONS.
AMMUNITION AND EXPLOSIVES STORAGE SAFETY (CERT) (AMMO 112) EXAM QUESTIONS WITH COMPLETE SOLUTIONS. Which hazard class/division would cause mass fragmentation if initiated? HD 1.1 You need to know storage compatibility of an explosive item before you store it. Which official regulation can you use as a reference for storage mixing? DA PAM 385-64 You have closed and sealed a magazine that will no longer be used. how often are you required to check the seal? Every 12 months You are planning the necessary firebreaks for a new ECM. You must have a 5-foot firebreak around the vents. You oversee a magazine with an integral lightning protection system (LPS). To ensure the LPS works, a certified professional must conduct an electrical test survey every 24 months What type of lighting protection system (LPS) does this building have? Mast You arrive at a magazine and find a truck parked just outside the magazine. Which statement applies? Vehicles must be parked at least 50 feet away from a magazine. Of the operations listed below, which operation is ALWAYS ALLOWED inside a magazine containing ammunition? Taking inventory You are painting this week. If the explosives operating facility has a fire extinguisher and a grounded storage cabinet designed for flammable materials, you are allowed to store enough paint inside the explosive operating facility for One day of work. You are doing work that will require you to use a torch that has a temperature above 228 degrees Fahrenheit (109 degrees Celsius). Which form must you fill out and have approved? Hot Work Permit Containers of ammunition should remain closed inside a magazine. You may open an outer container only to check/replace desiccant or to inventory the ammunition inside. You need to order a fire extinguisher for new MHE. Using the information on these fire extinguisher labels, which one is rated for all MHE? 5-B:C You need a forklift to work inside an ECM and no battery-powered ones are available. What other MHE can you use if it meets OSHA requirements for concentration of combustible products and noise?
Geschreven voor
- Instelling
- AMMUNITION AND EXPLOSIVES STORAGE SAFETY
- Vak
- AMMUNITION AND EXPLOSIVES STORAGE SAFETY
Documentinformatie
- Geüpload op
- 16 april 2024
- Aantal pagina's
- 3
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
ammunition and explosives storage safety cert a