Written by students who passed Immediately available after payment Read online or as PDF Wrong document? Swap it for free 4.6 TrustPilot
logo-home
Exam (elaborations)

Residential Electrical Services Quizzes With 100% Correct Answers. Graded A+

Rating
-
Sold
-
Pages
2
Grade
A
Uploaded on
17-04-2024
Written in
2023/2024

Residential Electrical Services Quizzes With 100% Correct Answers. Graded A+ An example of a location in a dwelling where a receptacle must have a GFCI protection is a Garage A type of cable with a corrugated sheath that has a maximum bend radius of 7 times the cable diameter is Type MC A residence with 1,000 square feet of living space has a general lighting load of 3000va According to the NEC, the small appliance loads in each kitchen area of a dwelling must be served by at least Two 120V, 20A small appliance branch circuits The NEC article that provides the rules for demand factors is Article 220 The NEC allows the load calculation for the grounded neutral conductor supplying electric ranges and dryers to have a demand factor of 70% Which of the following must never be used as a grounding electrode? underground gas piping and aluminum The minimum clearance of service drop conductors over a residential driveway is reduced to 12' (3.7m) when the voltage is limited to 300 volts The NEC article that lists the requirements for installing a service disconnect is Article 230 Romex is another name for Type NM cable Cables routed through bored holes in framing members must maintain a distance from the nearest edge of not less than 1-1/4 inches A current imbalance as low as 4 milliamps may be detected by a(n) GFCI breaker or outlet A switch used to control one or more lamps from two different locations is called a(n) Three-way switch The main bonding jumper is located at the Electrical Service The NEC article that covers the installation of pools and spas is Article 680 A GFCI sensor will trip when the current in the neutral load is less than the current in the hot load. Listed FMC may be used as an equipment grounding conductor if the circuit conductors are protected by overcurrent devices rated at 20 amps or less

Show more Read less
Institution
Course

Content preview

Residential Electrical Services Quizzes With 100% Correct
Answers. Graded A+
An example of a location in a dwelling where a receptacle must have a GFCI
protection is a
Garage
A type of cable with a corrugated sheath that has a maximum bend radius of 7
times the cable diameter is
Type MC
A residence with 1,000 square feet of living space has a general lighting load of
3000va
According to the NEC, the small appliance loads in each kitchen area of a
dwelling must be served by at least
Two 120V, 20A small appliance branch circuits
The NEC article that provides the rules for demand factors is
Article 220
The NEC allows the load calculation for the grounded neutral conductor
supplying electric ranges and dryers to have a demand factor of
70%
Which of the following must never be used as a grounding electrode?
underground gas piping and aluminum
The minimum clearance of service drop conductors over a residential driveway is
reduced to 12' (3.7m) when the voltage is limited to
300 volts
The NEC article that lists the requirements for installing a service disconnect is
Article 230
Romex is another name for
Type NM cable
Cables routed through bored holes in framing members must maintain a distance
from the nearest edge of not less than
1-1/4 inches
A current imbalance as low as 4 milliamps may be detected by a(n)
GFCI breaker or outlet
A switch used to control one or more lamps from two different locations is called
a(n)
Three-way switch
The main bonding jumper is located at the
Electrical Service
The NEC article that covers the installation of pools and spas is
Article 680
A GFCI sensor will trip when the
current in the neutral load is less than the current in the hot load.
Listed FMC may be used as an equipment grounding conductor if the circuit
conductors are protected by overcurrent devices rated at
20 amps or less

Written for

Course

Document information

Uploaded on
April 17, 2024
Number of pages
2
Written in
2023/2024
Type
Exam (elaborations)
Contains
Questions & answers

Subjects

$9.99
Get access to the full document:

Wrong document? Swap it for free Within 14 days of purchase and before downloading, you can choose a different document. You can simply spend the amount again.
Written by students who passed
Immediately available after payment
Read online or as PDF

Get to know the seller

Seller avatar
Reputation scores are based on the amount of documents a seller has sold for a fee and the reviews they have received for those documents. There are three levels: Bronze, Silver and Gold. The better the reputation, the more your can rely on the quality of the sellers work.
katoinyambi96 stuvia
Follow You need to be logged in order to follow users or courses
Sold
49
Member since
3 year
Number of followers
31
Documents
1267
Last sold
5 months ago

4.5

6 reviews

5
4
4
1
3
1
2
0
1
0

Recently viewed by you

Why students choose Stuvia

Created by fellow students, verified by reviews

Quality you can trust: written by students who passed their tests and reviewed by others who've used these notes.

Didn't get what you expected? Choose another document

No worries! You can instantly pick a different document that better fits what you're looking for.

Pay as you like, start learning right away

No subscription, no commitments. Pay the way you're used to via credit card and download your PDF document instantly.

Student with book image

“Bought, downloaded, and aced it. It really can be that simple.”

Alisha Student

Working on your references?

Create accurate citations in APA, MLA and Harvard with our free citation generator.

Working on your references?

Frequently asked questions