Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

CSIA FINAL EXAM PRACTICE QUESTIONS AND ANSWERS, LATEST UPDATED 2024/2025 (100% CORRECT)

Beoordeling
-
Verkocht
-
Pagina's
17
Cijfer
A+
Geüpload op
19-04-2024
Geschreven in
2023/2024

When a round flue is used for the lining of a fireplace chimney the proper fireplace opening to flue size ratio should be: Ans- 12:1 2. When unlined the smoke chamber walls shall be what thickness: 8" 3. When the opening of the firebox is 6 square feet the extension of the hearth should be: Ans- 20 inches 4. T or F the inner surfaces of the smoke chamber shall not be inclined more than 45 degrees from vertical: Ans- True 5. A level 2 inspection inspection of accessible areas of attics basements and crawlspaces: True 6. The purpose of a heat reclaimer is to: Ans- Extract heat from the flue gases 7. What best describes the allowable free air space around a flue tile: Ans1/4 inch to 4 inch 8. Crickets are recommended whenever the chimney is: Ans- 30" wide 9. The maximum allowable slope of an offset in a verticle flue is: Ans- 30 degrees 10. The area of the spark arrestor must not be less than three times the net CSIA EXAM PRACTICE QUESTIONS AND ANSWERS | ALL POSSIBLE QUESTIONS | LATEST UPDATED 2024/2025 (100% CORRECT) 2 / 6 free area of the chimney flue: True 11. What is the minimum thickness of a wythe: 4 inches nominal 12. chimney liners are listed to what standard: UL 1777 13. NFPA 211 recommends annual cleaning of chimneys fireplaces and vents- : False 14. The horizontal length of a single wall connector to a natural drat chimney or vent serving a single appliance shall be not more than of the height of the vertical height of the chimney: 75 % 15. The effective area of a connector for a single appliance shall be the area of the appliance flue collar: atleast 50% 16. Cleanout openings shall be prvided in all chimney flues serving free standing appliances: True 17. What species causes anaphylactic shock?: Bees 18. A type 3 ladder is rated for: 200 lbs 19. what are the stages of wood burning: drying pyrolysis charcoaling 20. The volume of gases which actually pass through the system as a result of draft is: Flow 21. Rectangular flues with aspect ratios greater than 2 to 1 shall be sized at least of the fireplace opening: 1:8 3 / 6 22. single wall connector clearance for an unlisted gas appliance with a draft hood is: 23. a level inspection is done with ladders and common hand tools: 2 24. Draft is the force or pressure difference between the inside and the outside of the venting system: true 4 / 6 25. NFPA 211 recommends chimney flues should be inspected: Annually 26. Two major factors that affect draft are: temperature differential and chimney height 27. what are factors of combustion efficiency: time turbulence and temperature 28. rabies is not carried by: Birds 29. what species carries histoplasmosis: Birds 30. what animal is known for roundworm: raccoons 31. what is NOT a step of a sweep: turn all gas appliances off 32. What is the proper class fire extinguisher for flammable liquids grease and oil: Class B 33. T or F - the area of a fireplace chimney flue cannot be greater than twice the area of the wood stove appliance outlet on an exterior chimney: True 34. a 24 gauge sheet metal panel with 1 inch airspace will reduce clearance to combustibles by when used as a wall protector: 66% ??? 35. According to NFPA 211 solid fuel burning appliances can be install in a garage: 36. Fuel air and heat are required components of what: combustion 37. The maximum width for a type 1 industrial grade ladder rating is: 250 pounds 5 / 6 38. where the trim of a mantel extends up to an 1 1/2 inch clearance to combustibles from the firebox opening should be at least: 6 inches 39. there must be inches of masonry between a wall thimble an combustible material: 12 40. smoke pipe diameter 6 through 10 inches has a required gauge of: 24 gauge 41. T or F - single wall chimneys on the exterior of a home can only be used for oil or gas: Flase 42. ONly allowable vent to be used in a stud cavity of a wall: BW Vent 43. A single wall connector used for oil and solid fuel appliances requires at least inches of clearance to combustible material: 18 44. T or F - A type L vent is used for low temp oil appliances and gas appliances: True 45. Unlisted appliances with legs providing 6 inches or more of ventilation under the appliance require what type of hearth: 46. connector pipe of thimble should extend into the chimney how far: flush with the interior flue wall 47. how many screws for connector pipe: 3 48. the formula for determining the cross sectional area of a square or rectan- 6 / 6 gular flue is?: EMAIL ME: For help with report, Assignment, Essay and thesis writing 7 / 6 49. two major factors influence the mount of draft what are they: temperature difference the outside and flue gas temp and the height of the chimney 50. The height of the smoke chamber should be no taller than: 51. connectors should maintain a pitch or rise of per foot of horizontal length of pipe from the appliance to the chimney or vent: 1/4 inch 52. Thermal shock can be caused by: a sudden rise or drastic drop in temperature 53. T or F Vent and chimney connectors shall not be covered with insulation- : True 54. Btus per cubic foot of gas: 2500 55. Sensible heat is: heat that you can feel 56. T or F latent heat is heat you can feel: False 57. Natural gas has how many BTU per cubic foot of gas: 1000 58. Propane gas has how many BTU per cubic foot of gas: 2500 59. creosote is a: carcinogenic 60. How do you reset a stack control on an oil fired appliance: PUll the lever out 1/4 of an inch than release slowly 61. Backpuffing is: smoke coming into the room in short sharp burst 62. The customer thinks there chimney was damaged in a recent hurricane you should recommend what: a level 2 inspection

Meer zien Lees minder
Instelling
CSIA
Vak
CSIA










Oeps! We kunnen je document nu niet laden. Probeer het nog eens of neem contact op met support.

Geschreven voor

Instelling
CSIA
Vak
CSIA

Documentinformatie

Geüpload op
19 april 2024
Aantal pagina's
17
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$15.99
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
STUDYROOM2026 Chamberlain College Of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
409
Lid sinds
3 jaar
Aantal volgers
212
Documenten
3903
Laatst verkocht
2 weken geleden

For all Nursing Test Banks visit my page. All Papers are Verified and Graded to Score A++ Wish you Success.

3.6

63 beoordelingen

5
22
4
14
3
14
2
4
1
9

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen