Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

Imaging VTNE Exam|Latest Update with 100% Correct Answers

Beoordeling
-
Verkocht
-
Pagina's
9
Cijfer
A+
Geüpload op
25-04-2024
Geschreven in
2023/2024

Imaging VTNE Exam|Latest Update with 100% Correct Answers All hard copies of radiographs, computed tomography (CT) scans, ultrasound images, and magnetic resonance imaging (MRI) studies are: the hospital's property and part of the patient's record For a radiograph to be considered admissible as evidence in a court of law, at least the _____ must be permanently imprinted onto it prior to developing. Patient name or identification number, owner name, hospital name, and date of the examination The term radiographic technique generally refers to: The machine's exposure settings (e.g., kVP, mAs) during a given examination X-rays cannot penetrate: Lead Concerning the filaments in the x-ray tube that produce electrons, which statement is most accurate? The small filament may melt more rapidly than the large filament if an excess load is placed on it. Why are rotating-anode x-ray machines more powerful than stationary-cathode x-ray machines? - The former allow greater dissipation of heat. - The former allow the use of a smaller focal spot with higher tube currents. - The former allow the use of shorter exposure times. (all answers are correct) The primary source of radiation exposure to the technician during radiography is scattered radiation, which can best be defined as: Lower-energy x-ray photons that have undergone a change in direction after interacting with structures in the patient's body The acronym kVP stands for _____ and controls the _____ of x-ray photons produced. Kilovolt peak; speed You have just taken a thoracic radiograph at 50 kVP and 100 mA at 1/10 second. The pet's breathing caused his chest to move during the exposure, resulting in a blurry image. On the retake, how can you correct for this motion to create a clear image of the same density? Reduce the time to 1/20 second and increase the mA to 200. You have radiographed a fractured femur in a large dog. The resulting image is too gray; that is, you can see many shades of gray and a lot of detail in the muscle layers, but the bone is also too gray, and bony fragments are difficult to see. How can you best correct your settings to create a clearer image of the fractured bone? Decrease the kVP.

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

Imaging VTNE Exam|Latest Update with 100% Correct
Answers
All hard copies of radiographs, computed tomography (CT) scans, ultrasound images, and magnetic
resonance imaging (MRI) studies are:
the hospital's property and part of the patient's record


For a radiograph to be considered admissible as evidence in a court of law, at least the _____ must be
permanently imprinted onto it prior to developing.
Patient name or identification number, owner name, hospital name, and date of the examination


The term radiographic technique generally refers to:
The machine's exposure settings (e.g., kVP, mAs) during a given examination


X-rays cannot penetrate:
Lead


Concerning the filaments in the x-ray tube that produce electrons, which statement is most accurate?
The small filament may melt more rapidly than the large filament if an excess load is placed on it.


Why are rotating-anode x-ray machines more powerful than stationary-cathode x-ray machines?
- The former allow greater dissipation of heat.
- The former allow the use of a smaller focal spot with higher tube currents.
- The former allow the use of shorter exposure times.
(all answers are correct)


The primary source of radiation exposure to the technician during radiography is scattered radiation,
which can best be defined as:
Lower-energy x-ray photons that have undergone a change in direction after interacting with
structures in the patient's body


The acronym kVP stands for _____ and controls the _____ of x-ray photons produced.
Kilovolt peak; speed


You have just taken a thoracic radiograph at 50 kVP and 100 mA at 1/10 second. The pet's breathing
caused his chest to move during the exposure, resulting in a blurry image. On the retake, how can you
correct for this motion to create a clear image of the same density?
Reduce the time to 1/20 second and increase the mA to 200.


You have radiographed a fractured femur in a large dog. The resulting image is too gray; that is, you
can see many shades of gray and a lot of detail in the muscle layers, but the bone is also too gray, and
bony fragments are difficult to see. How can you best correct your settings to create a clearer image
of the fractured bone?
Decrease the kVP.

, Which statement is most accurate concerning the effects of a change in focus-film distance (FFD)
when taking radiographs?
The mAs setting must be changed according to a standard mathematical formula.


How does one obtain the correct machine settings when taking a radiograph?
Settings are obtained from a "technique chart" created, by trial and error, specifically for the machine
one is using.


Concerning the use of film holders (cassettes) in veterinary radiography, which statement is most
accurate?
A "nonscreen" cassette is made of nonrigid cardboard or plastic and The most commonly used
cassettes in companion-animal practice are rigid and contain an image-intensifying screen.


Care of image-intensifying screens involves:
Cleaning them with a special solution or 70% isopropyl alcohol at least once monthly or whenever
screen artifacts are seen on a radiograph


The purpose of a grid is to:
Allow only the primary x-ray beam to pass through and prevent scattered radiation from reaching the
film and Increase the resolution of thicker body parts.


Most mistakes made in veterinary radiography are related to:
Improper processing techniques


Which statement concerning hand processing versus automatic-film processing of radiographs is most
accurate?
Both techniques require the use of fresh solutions and a well-ventilated darkroom.


X-ray film recycling and special units attached to fixer tanks allow the recovery of _____, a valuable
and reusable substance.
Silver


After exposing and developing an x-ray, you find the film totally white. What is the most likely cause
of this problem?
The film is unexposed.


In a practice using automatic x-ray processing equipment, the veterinary technician is expected to
Keep the processor clean and add fresh developer and fixer solutions as needed.


What is necessary to prevent "fogging," or partial exposure, of x-ray film in the darkroom?
- Absolutely no light leakage into the room
- A lock on the door to prevent entrance during film processing
- A safelight of correct wattage and filter type for the film used
(all answers listed)

Geschreven voor

Vak

Documentinformatie

Geüpload op
25 april 2024
Aantal pagina's
9
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.19
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
LectDan Teachme2-tutor
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
221
Lid sinds
3 jaar
Aantal volgers
157
Documenten
7985
Laatst verkocht
4 dagen geleden

4.0

48 beoordelingen

5
25
4
12
3
2
2
4
1
5

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen