Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold

Beoordeling
-
Verkocht
-
Pagina's
18
Cijfer
A+
Geüpload op
29-04-2024
Geschreven in
2023/2024

HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times soldHVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 300 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES (100% CORRECT AND VERIFIED ANSWERS) |AGRADE Rating 1 Rating 2 Rating 3 Rating 4 Rating 5 1 reviews| 5 times sold

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

HVAC JOURNEYMAN EXAM 2023-2024 AND
PRACTICE EXAM 300 QUESTIONS AND
CORRECT DETAILED ANSWERS (100%
CORRECT AND VERIFIED ANSWERS ALREADY
GRADED A+
Defects on gas piping or fittings shall be _____.
(A) Repaired
(B) Replaced or repaired and retested
(C) Repaired by a certified welder
(D) ignored, as the operating pressure is much less than the air test.

Every absorption refrigerating system supported from the ground shall rest on a
concrete slab extending not less than _____ the adjoining ground level.
(A) 3 inches below
(B) 3 inches above
(C) 6 inches below
(D) 6 inches above.

Any part of a venting system installed at an angle greater than 45 degrees from the
vertical is considered by code to be _____.
(A) vertical
(B) Horizontal
(C) A flat vent
(D) An offset vent
-ANSWER- B. any part of the venting installed at an angle GREATER than 45
degrees is considered by this code to be Horizontal UMC Section 802.6.1.1

Listed transition ducts f or clothes dryers shall not exceed_____ feet in length.
A.3
B.4
C.5
D.6.
-ANSWER- D. Dryers shall not exceed 6 feet in length. UMC Section 504.3.2.1

Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust
or solid materials shall be constructed of _____.
(A) Sheet metal
(B) polyvinyl chloride l
(C) Fiberglass
(D) A and C apply
-ANSWER- A. Shall Be Constructed of sheet metal. UMC Section. 5 0 6.1

Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust
or solid materials shall be constructed of _____

,A) Sheet metal
B) Polyvinyl chloride
C) Fiberglass
D) A and C apply
-ANSWER- A 511.2

Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less
than _____ inches. Is the Answer: A. 10" B. 12" C 16" D. 18". -ANSWER- D.
clearance of an unlisted vented gas fireplace at the sides and the rear not less than 18".
UMC Section 908.2(B)

Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame
(C) with a noncorrosive leak-detecting fluid (D) by increasing the air pressure during a
test until the leaks are heard as a whistle. -ANSWER- C. leaks in a gas piping
shall be located with a non corrosive leak detecting fluid. UMC Section 1316.4.2

Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8"
B.¼" C.½" D. 1" -ANSWER- A. Slope of not less than 1/8" per foot. UMC Section
309.1

The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches
or less in size is _____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG -ANSWER-
C. 18 Minimum Gauge note: AWG is the abbreviation for "gauge size" Table 6-7(B)

When smoke detectors are required as part of an automatic shutoff system, they shall
be installed in the _____. A. return air duct ahead of any fresh-air inlet(B) main supply
air duct served by such equipment(C) fresh-air inlet(D) main return and the main supply
duct. -ANSWER- B. shall be installed in the main supply air duct served by
equipment. UMC Section 609.0(5)

The largest fuel-burning appliance allowed in a room 100'W x 20'L x 8'H without
combustion air openingsis _____ Btu.(A) 80,000 (C) 140,000(B) 100,000 (D) 320,000
-ANSWER- 31 D. 701.2.1

Return air ducts that serve a dwelling unit shall be permitted to be of _____
construction? A.non-combustible B. combustible C. rated D. none of the above. -
ANSWER- B. Shall be permitted to be of combustible type UMC Section 602.2 Ex (1)

Solid fuel-burning appliances _____ be connected to a venting system that serves a
gas- or oil-burningappliance.(A) shall (B) may (C) shall not(D) with special approval may
-ANSWER- C. appliances shall not UMC Section 802.5.5.1

Any joint obtained by joining of metal parts with alloys that melt at temperatures higher
than 840°F, but lowerthan the melting temperature of the parts to be joined, is a _____
joint.(A) brazed(B) fused (D) soldered (C) welded -ANSWER- A. Is a brazed joint
UMC section 2 1 2.0

A vessel or arrangement of piping or tubing in which vaporized refrigerant is liquefied by
removal of heat is a _____.(A) compressor (C) evaporator(B) generator (D) condenser
-ANSWER- D. A condenser is the piping which vaporizes the refrigerant liquefied by
removal of heat, UMC Section 2 0 5.0

, is a _____.(A) compressor (C) evaporator(B) generator (D) condenser -ANSWER-
18 D 502.0

... -ANSWER- 19 C 1313.4

An appliance designed primarily to supply hot water equipped with automatic controls
limiting water -ANSWER- 20 B 1201.2.1.8

temperature to a maximum of 210°F is a _____.(A) water heater (C) expansion tank(B)
steam boiler (D) gas heater. -ANSWER- 21 A 507.1.3

... -ANSWER- 22 D 1129.0

A cooling coil is to be installed in a duct system containing an existing furnace heat
exchanger. Unless -ANSWER- 23 C 907.1

otherwise listed, the code requires that the air flows first through _____.(A) the heat
exchanger (C) a diverter unit(B) the cooling coil (D) a bypass duct -ANSWER- 24
C 903.5

... -ANSWER- 25 D 802.7.4.3

The space in which any floor furnace is installed shall be accessible by an opening in
the foundation not -ANSWER- 26 B 1312.3.2

less than _____.(A) 24'' x 24'' (C) 20'' x 20''(B) 24'' x 18'' (D) none of the above -
ANSWER- 27 C 507.2.1

... -ANSWER- 28 B 510.7.5

Buildings of more than _____ feet in height shall have an inside means of access to the
roof.(A) 14 (C) 15 (B) 16 (D) 20 -ANSWER- 29 C 701.1

... -ANSWER- Exxeption (1)

The clearance above the top of a casing or appliance for an unlisted upflow furnace is
_____ inches.(A) 12 (C) 8(B) 6 (D) 24 -ANSWER- 30 D 1129.0

... -ANSWER- 31 D 701.2.1

When required clearance from the lowest portion of a floor furnace to the ground cannot
be obtained, the -ANSWER- 32 B 602.2 Ex (1)

ground below and to the sides shall be excavated to form a _____ pit under the
furnace.(A) rectangular (C) 45-degree sloped(B) rounded (D) basin-like. -ANSWER-
33 C 802.5.5.1

... -ANSWER- 34 A 212.0

Geschreven voor

Vak

Documentinformatie

Geüpload op
29 april 2024
Aantal pagina's
18
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$30.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF

Maak kennis met de verkoper
Seller avatar
bilhahmbanya3

Maak kennis met de verkoper

Seller avatar
bilhahmbanya3 Chamberlain College Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
1
Lid sinds
2 jaar
Aantal volgers
0
Documenten
328
Laatst verkocht
10 maanden geleden

0.0

0 beoordelingen

5
0
4
0
3
0
2
0
1
0

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen