MASSACHUSETTS OIL BURNER LICENSE EXAM QUESTIONS WITH CORRECT ANSWERS | LATEST UPDATE 2024/2025 | GRADED A+
MASSACHUSETTS OIL BURNER LICENSE EXAM QUESTIONS WITH CORRECT ANSWERS | LATEST UPDATE 2024/2025 | GRADED A+. What are the 3 funtions of an Oil Burner nozzle? - correct answer Atomize, Meter, Patter. What are the 2 voltage circuits of a primary control? - correct answer Line & Low. What is the function of a fuse? - correct answer Protect circuit. What is the High Limit cut out? - correct answer Max safe Temp or Pressure setting. What is the High Limit cut in? - correct answer Cut out minus Differential. What is the "Max" Lockout time for a burner with a 3 GPH Flow Rate? - correct answer 45 Seconds. What is the minimum stack temperature which will allow a stack switch to work? - correct answer 400 degrees F When do you apply a permit to store oil? - correct answer 10 gallons. What is the "Main" function of an oil burner Primary Control? - correct answer Prove Flame. Stack Relay must be reset after lockout? True? or False? - correct answer True. What is the Required minimum height required for fill and vent pipes? - correct answer 3 Feet. MASSACHUSETTS OIL BURNER LICENSE EXAM QUESTIONS WITH CORRECT ANSWERS | LATEST UPDATE 2024/2025 | GRADED A+ What is the smallest vent pipe used for residential. - correct answer 1 inch 1/4 What size is the oil line for a residential burner? - correct answer 3/8 Largest oil capacity for residential without a license? - correct answer 10,000 Gallons At what height ceiling would a second thermal switch be required? - correct answer 12' A typical residential oil burner is also s/u to run Kerosene True? Or False? - correct answer False Permit to install an oil burner is issued by the? - correct answer State Fire Marshall Draft measurements are taken in what? - correct answer Inches of water column Pressure Relief for a Hot Water Boiler is? - correct answer 30 Psi Pressure Relief for a Steam Boiler is? - correct answer 15 Psi How many cubic feet of Air is required for a 1 gallon nozzle? - correct answer 1,400 If a power vent fails to start or shuts down during operation, will this affect the burner? Yes? Or No? - correct answer Yes A Hot Water Boiler needs a low water cut off if over 300,000 B.T.U's? - correct answer False What is the proper draft setting for an oil burner? - correct answer .02 Inches WC Taco Zones Valves draw .9 Amps? True? Or False? - correct answer True An oil burner tank must be how many feet minimum from an oil burner? - correct answer 5 Feet Minimum What is the gauge thickness for a 220 Gallon tank? - correct answer 12 Gauge What is a good cad cell reading in the light? - correct answer 300 -1,000 What is a good cad cell reading in the dark? - correct answer 100,000 What device sees flame failure and causes it to lockout? - correct answer Cad Cell A boiler has been flooded by recent rain. What would be the most common problem for a burner as a result - correct answer Electrical damage
Geschreven voor
- Instelling
- MASSACHUSETTS OIL BURNER LICENSE
- Vak
- MASSACHUSETTS OIL BURNER LICENSE
Documentinformatie
- Geüpload op
- 29 april 2024
- Aantal pagina's
- 10
- Geschreven in
- 2023/2024
- Type
- Tentamen (uitwerkingen)
- Bevat
- Vragen en antwoorden
Onderwerpen
-
oil burner license
-
latest update 2024
-
graded
-
verified answers
-
massachusetts oil burner license
-
oil burner license exam questions with answers
Ook beschikbaar in voordeelbundel