National Home Inspector State Practice Exam Course 2024 Q&A Verified
National Home Inspector State Practice Exam Course 2024 Q&A Verified Which of the following describes partial vapor pressure? A) Water vapor has a tendency to disperse itself equally in the available air. B) Water vapor causes new homes to require house wrap. C) Water vapor is common with forced induction natural gas furnaces. D) Water vapor is an indication of sick house syndrome. - CORRECT ANSWER-A) Water vapor has a tendency to disperse itself equally in the available air. In order for soffit vents to operate properly, there MUST be: A) A clear air channel between the roof boards and the insulation. B) An absence of insect, bee, and bird nests. C) Vents on both ends on the outside. D) Continuous vent strips on the length of the soffit. - CORRECT ANSWER-A) A clear air channel between the roof boards and the insulation. Home inspectors report receptacles with reversed polarity as potentially hazardous because: A) They contribute to the overheating of the receptacle. B) They increase the shock likelihood at connected equipment. C) Single phase appliance motors will run backwards. D) They trip ground fault circuit interrupter outlets. - CORRECT ANSWER-B) They increase the shock likelihood at connected equipment. The term "wet vent" refers to a: A) Vent that traps water and therefore stays wet. B) Vent located above the roof line and exposed to rain. C) Vent that runs outside an exterior wall. D) Waste line that also functions as a vent. - CORRECT ANSWER-D) Waste line that also functions as a vent. EIFS is a siding material that: A) Is used in commercial buildings only. B) Looks like stucco but lacks a wire mesh. C) Can be installed on top of a modified bitumen membrane. D) Can be installed on top of a masonry surface. - CORRECT ANSWER-B) Looks like stucco but lacks a wire mesh. The joints on the exterior of the brick chimney should be: A) Concaved. B) Raked. C) Open. D) Closed. - CORRECT ANSWER-A) Concaved When a water heater thermostat is set at 140 ° F or higher, a ______ should be installed to temper the water. A) Temperature probe B) Mixing probe C) Mixing valve D) Temper valve - CORRECT ANSWER-C) Mixing valve In a forced air furnace, the burners are used to generate heat in the: A) Heat exchanger. B) Draft diverter. C) Flue. D) Plenum. - CORRECT ANSWER-A) Heat exchanger.
Written for
- Institution
- Home inspector
- Course
- Home inspector
Document information
- Uploaded on
- May 2, 2024
- Number of pages
- 10
- Written in
- 2023/2024
- Type
- Exam (elaborations)
- Contains
- Questions & answers
Subjects
-
national home inspector state practice exam cours
-
which of the following describes partial vapor pre
-
the term wet vent refers to a
-
looking into an open electric service panel you se
Also available in package deal