Verified
True or False: The FireFighter may be installed next to a stand-alone battery-powered smoke
detector.
False
True or False: When performing a full system test, you may bypass any open doors or windows.
False
When programming an SKEY1, you must Always...?
Enable emergency key
True or False: When running power to the TAKE-345, polarity does not apply.
False
When programming the emergency key for an SKEY1, which zone/sensor types are recommended to
use?
Auxiliary and audible alarm
True or False: When installing an SMKT3, you must use the included screws and anchors
True
True or False: When installing the Fire Fighter, it is required to test the customer's existing smoke
detectors.
T
When installing a DW21, where is the approved location for the sensor?
Btw 6 & 2 in from the floor
When installing a DW11 on a vinyl or metal frame, what should you primarily use to mount the
sensor?
Double sided tape
Select all that apply: Which of the following materials can you use to group multiple ground terminals
in a Takeover module?
Wire caps or B connectors/Beans
What sensor are you not allowed to program using a translator?
Smoke detector
True or False: When installing the TAKE-345 you must always test the new 12v Battery before using it.
True
What is the output voltage of the transformer used to power the Smart Hub?
, 12 VDC
What is the minimum distance for placement of a CO3 from the corners on a wall?
12 in
True or False: The SMKT3 has only 2 functions: smoke and heat detection.
False
How would you program a CO3 if mounted on a hallway wall?
Loop 1, zone type 14
True or False: When installing a translator, you must program all of the existing sensors as new
equipment on the panel.
false
When programming a DW11 that has been installed on a window, which zone/sensor type should you
use?
3
True or False: The DW21 sensor should always be installed in the door frame
True
What equipment is used on all metal door frames
DW11
Which zone/sensor types are used when programming an SMKT3?
Type 9 smoke detection, type 8 freeze detection, type 9 heat detection
What is the correct height at which to install the PIR2?
7.5 ft
When programming a DW21, which loop number is used?
1
True or False: When programming a sensor into the panel, you can type in the serial number or
"learn" it in by triggering the device.
True
How would you program a GB2 when it is mounted on a master bedroom ceiling?
Loop 1, zone type 3
True or False: Panic Pendants are programmed as an Audible alarm (Type 07).
False