Geschreven door studenten die geslaagd zijn Direct beschikbaar na je betaling Online lezen of als PDF Verkeerd document? Gratis ruilen 4,6 TrustPilot
logo-home
Tentamen (uitwerkingen)

BACKFLOW TESTER EXAM ACTUAL QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 2024/2025 GRADED A+

Beoordeling
-
Verkocht
-
Pagina's
24
Cijfer
A+
Geüpload op
10-05-2024
Geschreven in
2023/2024

BACKFLOW TESTER EXAM ACTUAL QUESTIONS WITH COMPLETE SOLUTIONS VERIFIED 2024/2025 GRADED A+ A double check valve assembly is installed 12 above the floor for? Maintenance A low hazard Backflow preventer is a? Double Check valve assembly A field test report for a double check will include the manufacturer name, model, size and ?? Serial number Double check valve assembly components are?? Independently acting A double check valve assembly hydraulic use is?? Continuous A detector assembly contains a device of equal? Protection Each check valve of a double check valve assembly is forced to load to what psi? 1.0 A double check valve assembly is required to contain test cocks that total? 4 A double check valve assembly is designed to detect low flow rates up to what gpm 1 A double check detector assembly is referenced as a? DCDA A double check valve assembly installed in a vertical flow down orientation is only allowed? If approved for that orientation The max height the water will rise in a barometric loop is dependent of? Atmospheric pressure The number 1 check spring on a RP has a minimum spring tension requirement of? 5 psi Relief valves are designed to open to atmosphere when supply pressure becomes less than? 2 psi A RP has an inlet supply pressure of 97psi. The pressure in the zone will be at least? 92 psi The purpose of an RP is to? Prevent contamination from entering the water supply The application of an RP is? Any hazard application The max level of protection provided by a RP is? Health hazard A RP zone pressure should be 5 psi - less than supply A RP fouled check valve number 1 may be indicated by Continuous dripping With both shut off valves closed and test cocks 3-4 open, a continuous discharge from test cock 4 might indicate a leak through Shut off valve number 2 Lock out tag out must be used All the above An RP relief valve is loaded to Push the valve away from its seat The purpose of RP check valve number 1 loading is Create a reduction in water pressure Intermittent relief valve discharge from a RP is probably caused by Water hammer Back pressure to a RP fouled check valve number 2 likely Forced the relief valve to open and discharge An air gap separation must be maintained at a RP,s Relief valve discharge An RP's "Buffer" can be described as Difference between the check valve 1 loading and the relief valve opening point When an RP is installed vertically, the relief valve discharge must be Lower than check valve number 1

Meer zien Lees minder
Instelling
Vak

Voorbeeld van de inhoud

BACKFLOW TESTER EXAM ACTUAL QUESTIONS WITH

COMPLETE SOLUTIONS VERIFIED 2024/2025 GRADED A+


A double check valve assembly is installed 12 above the floor for?

Maintenance

A low hazard Backflow preventer is a?

Double Check valve assembly

A field test report for a double check will include the manufacturer name, model,

size and ??

Serial number

Double check valve assembly components are??

Independently acting

A double check valve assembly hydraulic use is??

Continuous

A detector assembly contains a device of equal?

Protection

Each check valve of a double check valve assembly is forced to load to what psi?

1.0

A double check valve assembly is required to contain test cocks that total?

4

A double check valve assembly is designed to detect low flow rates up to what

gpm

,1

A double check detector assembly is referenced as a?

DCDA

A double check valve assembly installed in a vertical flow down orientation is

only allowed?

If approved for that orientation

The max height the water will rise in a barometric loop is dependent of?

Atmospheric pressure

The number 1 check spring on a RP has a minimum spring tension requirement

of?

5 psi

Relief valves are designed to open to atmosphere when supply pressure

becomes less than?

2 psi

A RP has an inlet supply pressure of 97psi. The pressure in the zone will be at

least?

92 psi

The purpose of an RP is to?

Prevent contamination from entering the water supply

The application of an RP is?

Any hazard application

The max level of protection provided by a RP is?

Health hazard

, A RP zone pressure should be

5 psi - less than supply

A RP fouled check valve number 1 may be indicated by

Continuous dripping

With both shut off valves closed and test cocks 3-4 open, a continuous discharge

from test cock 4 might indicate a leak through

Shut off valve number 2

Lock out tag out must be used

All the above

An RP relief valve is loaded to

Push the valve away from its seat

The purpose of RP check valve number 1 loading is

Create a reduction in water pressure

Intermittent relief valve discharge from a RP is probably caused by

Water hammer

Back pressure to a RP fouled check valve number 2 likely

Forced the relief valve to open and discharge

An air gap separation must be maintained at a RP,s

Relief valve discharge

An RP's "Buffer" can be described as

Difference between the check valve 1 loading and the relief valve opening point

When an RP is installed vertically, the relief valve discharge must be

Lower than check valve number 1

Geschreven voor

Vak

Documentinformatie

Geüpload op
10 mei 2024
Aantal pagina's
24
Geschreven in
2023/2024
Type
Tentamen (uitwerkingen)
Bevat
Vragen en antwoorden

Onderwerpen

$10.49
Krijg toegang tot het volledige document:

Verkeerd document? Gratis ruilen Binnen 14 dagen na aankoop en voor het downloaden kun je een ander document kiezen. Je kunt het bedrag gewoon opnieuw besteden.
Geschreven door studenten die geslaagd zijn
Direct beschikbaar na je betaling
Online lezen of als PDF


Ook beschikbaar in voordeelbundel

Maak kennis met de verkoper

Seller avatar
De reputatie van een verkoper is gebaseerd op het aantal documenten dat iemand tegen betaling verkocht heeft en de beoordelingen die voor die items ontvangen zijn. Er zijn drie niveau’s te onderscheiden: brons, zilver en goud. Hoe beter de reputatie, hoe meer de kwaliteit van zijn of haar werk te vertrouwen is.
NurseAdvocate chamberlain College of Nursing
Volgen Je moet ingelogd zijn om studenten of vakken te kunnen volgen
Verkocht
497
Lid sinds
2 jaar
Aantal volgers
77
Documenten
12046
Laatst verkocht
22 uur geleden
NURSE ADVOCATE

I have solutions for following subjects: Nursing, Business, Accounting, statistics, chemistry, Biology and all other subjects. Nursing Being my main profession line, I have essential guides that are Almost A+ graded, I am a very friendly person: If you would not agreed with my solutions I am ready for refund

4.6

239 beoordelingen

5
193
4
14
3
15
2
6
1
11

Recent door jou bekeken

Waarom studenten kiezen voor Stuvia

Gemaakt door medestudenten, geverifieerd door reviews

Kwaliteit die je kunt vertrouwen: geschreven door studenten die slaagden en beoordeeld door anderen die dit document gebruikten.

Niet tevreden? Kies een ander document

Geen zorgen! Je kunt voor hetzelfde geld direct een ander document kiezen dat beter past bij wat je zoekt.

Betaal zoals je wilt, start meteen met leren

Geen abonnement, geen verplichtingen. Betaal zoals je gewend bent via iDeal of creditcard en download je PDF-document meteen.

Student with book image

“Gekocht, gedownload en geslaagd. Zo makkelijk kan het dus zijn.”

Alisha Student

Bezig met je bronvermelding?

Maak nauwkeurige citaten in APA, MLA en Harvard met onze gratis bronnengenerator.

Bezig met je bronvermelding?

Veelgestelde vragen